Literature DB >> 26155561

Does Hollowing of Complete Denture Enhance Retention? - A Pilot Study.

Ashish Kalra1, Kanika Singh Dhull2, Satish R Iyer3, Manish Mittal4, Shilpa Kalra5, Shweta Yadav6.   

Abstract

INTRODUCTION: Prosthetic rehabilitation is an extremely challenging task in extreme resorption cases of the maxillary denture-bearing area. Reducing the weight of a maxillary obturator has been seen as beneficial. But whether reducing the weight of conventional complete denture also increases retention or not, is still very dubious. The aim of this pilot study was to determine the effect of maxillary denture weight on denture retention and stability.
MATERIALS AND METHODS: For this study, a total of 10 patients were considered for the pilot study (06 female and 04 male) with an average age of 70 y. Each patient was provided with two sets of maxillary complete dentures, one hollow labeled as A and one conventional maxillary denture labeled as B.
RESULTS: It was shown that mean values for retention using MKIS for retention for hollow dentures (A) was 7.8 and for conventional dentures (B) it was 8.2 and the stability for maxillary dentures was more with conventional dentures (B) than hollow maxillary dentures (A) and it was significant as p-value was 0.015 (p<.1).
CONCLUSION: The denture retention and stability, chewing and comfort values of conventional dentures and hollow dentures were slightly better for conventional dentures.

Entities:  

Keywords:  Edentulous; Prosthetic rehabilitation; Shim

Year:  2015        PMID: 26155561      PMCID: PMC4484153          DOI: 10.7860/JCDR/2015/12602.5929

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  12 in total

1.  A modified Kapur scale for evaluating denture retention and stability: methodology study.

Authors:  A M Olshan; N M Ross; S Mankodi; S Melita
Journal:  Am J Dent       Date:  1992-04       Impact factor: 1.522

2.  Internally weighted mandibular dentures.

Authors:  A J Hurtado
Journal:  J Prosthet Dent       Date:  1988-07       Impact factor: 3.426

3.  The influences of fear, anxiety, and depression on the patient's adaptive responses to complete dentures. Part I.

Authors:  N Friedman; H M Landesman; M Wexler
Journal:  J Prosthet Dent       Date:  1987-12       Impact factor: 3.426

4.  Weighted mandibular dentures.

Authors:  J H Wormley; D A Brunton
Journal:  J Prosthet Dent       Date:  1974-07       Impact factor: 3.426

5.  Adding weight may promote retention of lower denture.

Authors:  E F Brennom
Journal:  Dent Surv       Date:  1973-03

6.  Fabrication of a hollow-bulb obturator.

Authors:  K E Brown
Journal:  J Prosthet Dent       Date:  1969-01       Impact factor: 3.426

7.  A clinical evaluation of denture adhesives.

Authors:  K K Kapur
Journal:  J Prosthet Dent       Date:  1967-12       Impact factor: 3.426

8.  A hollow complete lower denture.

Authors:  R A Holt
Journal:  J Prosthet Dent       Date:  1981-04       Impact factor: 3.426

9.  Age and denture experience as determinants in patient denture satisfaction.

Authors:  M Weinstein; J Schuchman; J Lieberman; P Rosen
Journal:  J Prosthet Dent       Date:  1988-03       Impact factor: 3.426

10.  The influence of clinical variables on patients' satisfaction with complete dentures.

Authors:  M A van Waas
Journal:  J Prosthet Dent       Date:  1990-03       Impact factor: 3.426

View more