| Literature DB >> 26155011 |
Priscila Costa1, Amélia Fumiko Kimura1, Debra Huffman Brandon2, Eny Dorea Paiva3, Patricia Ponce de Camargo4.
Abstract
OBJECTIVE: to develop a risk score for unplanned removal of peripherally inserted central catheter in newborns.Entities:
Mesh:
Year: 2015 PMID: 26155011 PMCID: PMC4547071 DOI: 10.1590/0104-1169.0491.2578
Source DB: PubMed Journal: Rev Lat Am Enfermagem ISSN: 0104-1169
Distribution of risk factors for unplanned removal of peripherally inserted central catheters in newborn babies. São Paulo, Brazil 2010 to 2012
| Risk factors | Unplanned removal | Relative risk (95% confidence interval) | p value | ||
|---|---|---|---|---|---|
| Yes (N=156) | No (N=263) | ||||
| Weight | ≤1500 g | 80(51.9%) | 102(39.2%) | 1.35[1.07-1.76] | 0.01 |
| >1500g | 74(48.1%) | 158(60.8%) | |||
| Gestational age | ≤32 weeks | 71(45.5%) | 82(31.2%) | 1.78[0.66-0.93] | 0.004 |
| >32 weeks | 85(54.4%) | 181(68.8%) | |||
| Postnatal age | ≤7 days | 93(59.6%) | 224(85.2%) | 1.84[1.41-2.38] | <0.001 |
| >7 days | 63(40.4%) | 39(14.8%) | |||
| Clinical diagnosis | |||||
| Sepsis | Yes | 38(24.4%) | 40(15.4%) | 1.26[1.0-1.59] | 0.03 |
| No | 118(75.6%) | 220(84.4%) | |||
| Heart disease | Yes | 35(22.4%) | 30(11.5%) | 1.41[1.08-1.86] | 0.005 |
| No | 121(76.6%) | 230(88.5%) | |||
| Transient metabolic disorder | Yes | 22(14.1%) | 9(3.5%) | 2.24[1.28-3.91] | <0.001 |
| No | 134(85.9%) | 251(96.4%) | |||
| Previous insertion of PICC* | Yes | 52(33.3%) | 29(11%) | 1.93[1.43-2.61] | <0.001 |
| No | 104(66.7%) | 234(89%) | |||
| Insertion site | Upper limb | 109(71.7%) | 190(73.6%) | Reference | 0.65 |
| Lower limb | 22(14.5%) | 41(15.9%) | 0.95[0.66-1.38] | ||
| cervical region | 16(10.5%) | 18(7%) | 1.29[0.87-1.90] | ||
| Cephalic region | 5(3.3%) | 9(3.5%) | 0.97[0.47-2] | ||
| Polyurethane double-lumen catheter | Yes | 96(61.5%) | 128(49.2%) | 1.20[1.03-1.39] | 0.001 |
| No | 60(38.5%) | 132(50.8%) | |||
| Catheter tip in noncentral position | Yes | 32(21.2%) | 28(11%) | 1.40[1.06-1.86] | 0.008 |
| No | 119(78.8%) | 227(89%) | |||
| Number of intravenous solutions – | Average | 3,47(1.73) | 2.99(1.5) | 0.003 | |
*PICC = peripherally inserted central catheter
Risk factors for unscheduled removal of peripherally inserted central catheter in newborn babies identified by logistic regression. São Paulo, Brazil 2010 to 2012
| Risk factor | β Coefficient | Standard error | Z value | P value | Odds ratio [95%Confidence interval] |
|---|---|---|---|---|---|
| Intercept | -2.08 | 0.39 | -5.31 | <0.001 | |
| One or more previous insertions | 1.36 | 0.28 | 4.93 | <0.001 | 3.89 [2.28 – 6.74] |
| Transient metabolic disorders | 1.51 | 0.43 | 3.51 | <0.001 | 4.52 [2.00- 10.99] |
| Number of solutions (continuous) | 0.27 | 0.12 | 2.21 | 0.03 | 1.30 [1.03 – 1.67] |
| PICC*Polyurethane double-lumen catheter | 1.39 | 0.53 | 2.63 | 0.01 | 4.02 [1.44 – 11.54] |
| Noncentral position of tip | 0.74 | 0.30 | 2.46 | 0.01 | 2.10 [1.16 – 3.82] |
*PICC= peripherally inserted central catheter
.Risk score for unplanned removal of peripherally inserted central catheter in newborns . São Paulo, Brazil 2010 to 2012