Literature DB >> 26154454

Low-level laser therapy effects on pain perception related to the use of orthodontic elastomeric separators.

Rachel D'Aurea Furquim1, Renata Correa Pascotto1, José Rino Neto2, Jefferson Rosa Cardoso3, Adilson Luiz Ramos1.   

Abstract

INTRODUCTION: Some patients refer to pre-banding orthodontic separation as a painful orthodontic procedure. Low-level laser therapy (LLLT) has been reported to have local analgesic effect.
OBJECTIVE: The aim of this single-blind study was to investigate the perception of pain caused by orthodontic elastomeric separators with and without a single LLLT application (6J).
METHODS: The sample comprised 79 individuals aged between 13 and 34 years old at orthodontic treatment onset. Elastomeric separators were placed in first maxillary molars at mesial and distal surfaces and kept in place for three days. The volunteers scored pain intensity on a visual analogue scale (VAS) after 6 and 12 hours, and after the first, second and third days. One third of patients received laser applications, whereas another third received placebo applications and the remaining ones were controls. Applications were performed in a split-mouth design. Thus, three groups (laser, placebo and control) were assessed.
RESULTS: No differences were found among groups considering pain perception in all periods observed.
CONCLUSION: The use of a single-dose of LLLT did not cause significant reduction in orthodontic pain perception. Overall pain perception due to orthodontic separator placement varied widely and was usually mild.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26154454      PMCID: PMC4520136          DOI: 10.1590/2176-9451.20.3.037-042.oar

Source DB:  PubMed          Journal:  Dental Press J Orthod        ISSN: 2176-9451


INTRODUCTION

Pain is often associated with dental procedures. It has been reported that 28% of orthodontic patients consider discontinuing treatment due to fear of pain, while 39% of them claim it is the worst feature of orthodontic appliances.1 After placement of orthodontic accessories, such as elastomeric separators, archwires or activation loops, the affected areas undergo a painful process triggered by pressure and stress.2 , 3 Although pain is subjective and may vary among individuals, studies show that all patients, regardless of age, have reported some degree of pain during treatment.2 , 3 It has been observed that, due to being mild to moderate and often transient pain,4 medications are not routinely prescribed in orthodontic practice, unless discomfort becomes intolerable.5 Moreover, medications can produce side effects and are contraindicated for allergic patients.6 , 7 Low-level laser therapy (LLLT) has been reported to reduce inflammation and pain by reducing prostaglandin and interleucine production;7 and has, therefore, been proposed as an alternative analgesic in Dentistry.6 - 14 However, few clinical LLLT trials15 have been performed with clear methods, significant samples, homogeneous groups and a placebo group. Furthermore, it is not clear to what extent the use of pre-banding elastomeric orthodontic separators is perceived by patients as painful. In light of the above, the aim of this study was to assess pain perception associated with elastomeric separators with and without a single application of 808-nm LLLT.

MATERIAL AND METHODS

This study was approved by Universidade Estadual de Maringá Institutional Review Board (0315.0.093.000-09) and all volunteers and legal guardians signed an informed consent form. Sample size calculation was performed with a confidence level of 95%, 5-mm margin of error, 8.1 mm standard deviation, and an infinite population.9 Although the results showed that each group should comprise 11 individuals, 25 subjects were initially assigned to each group, given the inclusion of the placebo group and the clinical nature of the research. The following inclusion criteria were applied: complete permanent dentition in the maxillary arch, except for third molars, and good systemic health. Patients who had undergone prior oral LLLT; those who presented with systemic problems, such as diabetes or metabolic diseases, which may interfere in the inflammatory process; pregnant or lactating patients; those who were using painkillers or anti-inflammatory medications and/or presented with clear signs of periodontal disease, such as bleeding or signs of inflammation (pain, heat, swelling and redness) were excluded from the study. The initial sample comprised 100 patients and all of them had the following maxillary teeth separated with elastomeric separators (Morelli - Sorocaba, SP, Brazil): between the second premolar and first molar (mesial of first molar), and between the first molar and second molar (distal of first molar).6 , 12 Patients were randomly divided into four initial groups in which maxillary molars on both sides received elastomeric separators. Each group was approached differently, as follows: Group 1, LLLT applied on the left side and placebo on the right side (blind) (SOLce); Group 2, LLLT applied on the left side and control on the right side (aware) (SOLci); Group 3, control on the right side and placebo on the left side (blind) (SOce); Group 4, control on both sides (aware) (SOci). The term "blind" refers to the fact that patients were not aware of the procedure (placebo). In the group "orthodontic separation with laser application (blind)" (SOLce), LLLT was applied immediately after elastomeric separators placement in the maxillary left first molars. On the right side, placebo applications were performed, with the LLLT device producing beeps without firing the laser. Since the infrared laser used is not visible and protection glasses were on, patients could not detect any differences between the two applications. In the group "orthodontic separation with laser application (aware)" (SOLci), laser therapy was performed only on the left side, as in group 1; but this time, patients were aware that the laser would be applied on one side, only. On the other side, no placebo applications were performed. In the group "orthodontic separation (blind)" (SOce), recorded as group 3, no LLLT was applied. However, on the left side, placebo applications were performed as previously described. Patients did not receive laser applications on the other side. Thus, the psychological factor was assessed in terms of what extent to which it interferes in the pain process, inducing the patient into thinking that the side supposedly treated with some sort of therapy would hurt less. In the group "orthodontic separation (aware)" (SOci), recorded as group 4, the volunteers received neither placebo nor laser applications, thus fully characterizing it as the control group. Twenty-one subjects dropped out of the study or provided incorrect data: five of them reported severe pain (two from the SOLce group, one from the SOce group and two from the SOci group); and sixteen lacked complete data in one of the study periods (three from the SOce group and 13 from the SOci group). Therefore, final data distribution (n = 79) was as follows: SOLce (n = 23), SOLci (n = 25), SOce (n = 21) and SOci (n = 10). Considering the sample in terms of the sides assessed (n = 158), distribution was as follows: laser = 30.37% (n = 48), placebo = 27.48% (n = 44), control = 41.77% (n = 66). Applications were performed with a Whitening Lase II device (DMC Equipment Ltda., São Carlos, Brazil) which has two laser probes with distinct functions: a smaller laser probe for LLLT and a curved laser probe for teeth bleaching. The laser therapy probe in infrared mode (AsGaAl) was used. A standard guide was used for all patients (after disinfection with 70% alcohol and protection with film paper in the foam area) based on the average size (13 mm) of the buccal roots of the maxillary first molar.16 The device was placed on the occlusal surface of teeth and supported between the marginal ridges of the teeth involved. The guide was fabricated so that the first application was performed 5 mm above the gingival papilla, approaching patient's bone crest region. The total length of the guide was 12 mm, allowing three applications, 4 mm apart from each other, to be performed (Fig 1).
Figure 1.

Guide and scheme of laser applications used in the study. A) 10-second application in the mesio-cervical region; B) 10-second application in the mesio-medial region; C) 10-second application in the mesio-apical region. The three regions (cervical, medial and apical) also received laser applications distally, thereby totaling 60 seconds per tooth (6 J / tooth).

The wavelength used was 808 nm, with a fluency of 80 J/cm2, as recommended by the manufacturer (DMC Equipment Ltda., São Carlos, Brazil), thereby totaling approximately 6 J of energy per tooth (1 x 60 s x 100 mW).The probe of the device remained in contact with the gingival tissue during applications. Elastomeric separators were placed and laser applications performed by the same previously trained and calibrated operator. Subsequently, all patients were instructed to rate their level of spontaneous pain on a visual analogue scale (VAS). Initial scores were assigned as soon as the patient arrived at the office and before any procedure was carried out. This initial score made it possible to judge whether or not the patient already felt some pain, which was not related to the separation procedure, in the teeth involved in the study. After separation, patients' pain levels were recorded 6 hours, 12 hours and 1, 2 and 3 days following separation. The scores assigned by the patient on the visual analogue scales were measured with a caliper (Mitutoyo, Japan). A zero score, located on the left side of the scale, suggested no pain; while a 100 (100 mm) score, at the right end of the scale, suggested maximum pain. The center of the scale corresponded to a score equal to 50 and suggested moderate pain. This information was provided to the subjects before they started assigning scores on their dental history cards, which patients took home. Data were tested for normality of distribution by means of the Shapiro-Wilk test. Should normal distribution not be found, data were presented using median and their quartiles (1st and 3rd). Pain perception was assessed by analysis of variance (ANOVA) for repeated measures. Mauchly's sphericity test was also applied and, whenever violated, technical corrections were performed by Greenhouse-Geisser test. Statistical significance was set at 5% and analyses were carried out by means of SPSS version 15.0.

RESULTS

Patients' mean age was 23.4 ± 6.3 years for group SOLce (9 men and 14 women); 22.3 ± 4.1 years for group SOLci (8 men and 17 women); 23 ± 4.7 years for group SOce (6 men and 15 women) and 25.5 ± 7.8 years for group SOci (1 man and 9 women) (Table 1).
Table 1.

Demographic analysis of group data.

SOLceSOLciSOceSOci
(n = 23)(n = 25)(n = 21)(n = 10)
   Age (years) (mean ± SD) 23.4 ± 6.3 22.3 ± 4.1 23 ± 4.7 25.5 ± 7.8
    Sex
   Male - n (%) 9 (39.1%) 8 (32%) 6 (28.6%) 1 (10%)
   Female - n (%) 14 (60.9%) 17 (68%) 15 (71.4%) 9 (90%)*

p < 0.05.

p < 0.05. Data frequency distribution for age and sex was performed in a similar manner (p > 0.05), confirming the homogeneity of the sample. Female patients were predominant only in the control group (Table 1). This fact did not hinder comparison among the laser, placebo and control sides (Tables 2 and 3).
Table 2.

Median and median quartiles (1st - 3rd) of the SOLce, SOLci, SOce, SOci groups in all periods analyzed, comparing left and right sides.

SOLceSOLciSOceSOci
(n = 23)(n = 25)(n = 21)(n = 10)
Left side (laser) Right side (placebo light)Left side (laser)Right side  (no light)Left side (placebo light) Right side (no light)Left side (no light)Right side (no light)
Md (1st – 3rd)Md (1st – 3rd)Md (1st – 3rd)Md (1st – 3rd)Md (1st – 3rd)Md (1st – 3rd)Md (1st – 3rd)Md (1st – 3rd)
6 h 1.2 (0 – 12.4) 0.9 (0 – 11.8) 0 (0 – 8) 2.7 (0 – 21.8) 1.4 (0 – 19.9) 3.1 (0 – 12.6) 3.6 (0 – 12.9) 1.7 (0 – 12.2)
12 h 4.5 (0 – 23.3) 2.5 (0 – 16) 3 (0 – 10.8) 4.2 (0 – 11.2) 0.49 (0 – 22.7) 1.3 (0 – 9.3) 4.5 (0.8 – 7) 4.1 (0 – 7.2)
1 day 4.8 (0 – 18.3) 2.4 (0 – 16.1) 2.4 (0 – 23.6) 3.2 (0 – 26.7) 1.3 (0 – 24.8) 0.9 (0 – 19.5) 1.6 (0 – 4.8) 1.8 (0.5 – 6.5)
2 days 3.2 (0 – 11.8) 0 (0 – 12.5) 4.5 (0 – 10.7) 4 (0 – 17.8) 0 (0 – 11.7) 0.8 (0 – 12.8) 1.4 (0 – 6.2) 1.9 (1.1 – 4.3)
3 days 0 (0 – 6.3) 0 (0 – 3.3) 0.5 (0 – 9.1) 0.8 (0 – 13.7) 0 (0 – 8.4) 0 (0 – 5.8) 0 (0 – 5.4) 0.5 (0 – 3.1)

Md = median; (1st - 3rd) = first and third quartiles; F Greenhouse-Geisser test= 1.78; p = 0.16.

Table 3.

Median and median quartiles (1st - 3rd) of scores side by side with laser, placebo and control sides applications in all periods analyzed.

Laser (n = 44)Placebo (n = 44)Control (n = 66)
Md (1st – 3rd)Md (1st – 3rd)Md (1st – 3rd)
6 h 0.6 (0 – 8.3) 1.1 (0 – 8) 2.9 (0 – 14.8)
12 h 4.2 (0 – 13.6) 1.7 (0 – 17.7) 3.4 (0 – 10.7)
1 day 2.3 (0 – 18.6) 1.9 (0 – 22.3) 1.7 (0 – 19.8)
2 days 2.8 (0 – 11) 0 (0 – 11.6) 2.9 (0 – 12.9)
3 days 0 (0 – 6.4) 0 (0 – 6.5) 0.1 (0 – 6.2)

Md = median; (1st - 3rd) = first and third quartiles; F Greenhouse-Geisser test = 1.16; p = 0.32.

Md = median; (1st - 3rd) = first and third quartiles; F Greenhouse-Geisser test= 1.78; p = 0.16. Md = median; (1st - 3rd) = first and third quartiles; F Greenhouse-Geisser test = 1.16; p = 0.32. All volunteers assigned zero to pain perception score at baseline. Among the 79 volunteers, 12.65% (n = 10) did not report any pain over all evaluated periods; and only 15.18% (n = 12) reported pain levels equal to or greater than 40 in at least one of the assessment periods. No statistical difference was found (p = 0.16) between left and right sides in all periods compared across all groups (Table 2). Although the median was low, the pain peak perceived by patients occurred between 12 hours and 1 day (Tables 2 and 3). LLLT applications, placebo applications and control sides were compared during the scoring periods. The three situations showed no statistical difference (p = 0.32) in terms of pain level (Table 3).

DISCUSSION

Corroborating the results of previous studies,2 , 3 the pain caused by orthodontic procedures (separators or leveling archwires) reaches its peak 12 and 24 hours after placement (Table 3). However, in this study, pain perception, as shown in VAS scores, was highly variable, with a relatively low median. It is a known fact that separators cause pain. Despite reports by some people who do not feel any pain whatsoever,6 most authors report that, although pain intensity or location may vary, all patients eventually complain, which indicates that the procedures performed in orthodontic practice are always a nuisance.2 , 3 , 4 , 7 In the present study, 12.65% (n = 10) did not report any pain and only 15.18% (n = 12) reported pain levels equal to or greater than 40. If the five volunteers who dropped out of the study after reporting too much pain were to be included, this percentage would rise to 18% of the initial sample. Those distributions related to pain were similar among groups. Therefore, patients who claimed that the pain caused by orthodontic separation was relevant represented a minority of the sample. It is worth noting that the effects of LLLT could only be noted if the majority of subjects had perceived increased pain. Nevertheless, a detailed assessment of patients reporting pain greater than or equal to 40 on VAS, in at least one of the periods, revealed that six of them reported feeling greater pain on the laser side, compared to placebo or control, while six of them assigned lower scores to the laser side. Although pain is seen as a subjective and, therefore, hard-to-assess variable, the use of visual analogue scales, as it was the case in this study, has been widely reviewed and is nowadays regarded as a reliable method.6 , 9 , 17 In comparison to other investigations on orthodontic pain perception, the present study disclosed lower VAS score values. Fujiyama et al12 reported higher scores that reached 80, 12 and 24 hours after placing separators and when no laser was applied; and 40 when it was applied; however, no placebo group was used. Our study corroborates that pain registered in VAS scores varies from mild to moderate.18 - 23 It is worth noting that, as performed in a variety of other studies,6 , 7 , 11 , 12 , 18 volunteers were asked to score spontaneous pain; however, other authors registered other situations, such as biting, to which patients sometimes referred as being more painful than a spontaneous symptom.22 , 24 In the present study, a split-mouth, single-blind model was adopted and a placebo side was included, which allowed the authors to compare intrasubject pain perception with and without LLLT. Lim et al6 conducted a similar study with separators and found no difference between the placebo and laser sides. Additionally, their scores were similar to those found in the present study, which also shows considerable variability.6 Those data also corroborate a recent study performed by Abtahi et al.18 Youssef et al,13 Tortamano et al,14 Turhani et al11 and Harazaki et al,7 for instance, applied laser in patients undergoing orthodontic treatment. The authors assessed pain during alignment and leveling or when performing canine retraction. Given that these procedures involve a higher number of teeth, they may enhance pain perception and underscore LLLT effects. Thus, it does not seem reasonable to compare these results with the present study which assessed pain perception in the presence of elastomeric separators. A wide range of laser types, with different wavelengths and energy doses, can be found in the literature. AsGaAl diode laser, used in studies by Youssef et al,13 Tortamano et al14 and Lim et al,6 was also used in the present study. Moreover, Harazaki et al7 used HeNe laser whereas Fujiyama et al12 used CO2 laser. At lower wavelengths, for instance, 632.8 nm7 and 670 nm11, no difference, in terms of pain intensity, was reported between groups with or without laser applications. Nevertheless, the use of high-level laser, with wavelength of 808 nm, revealed statistically significant pain reduction in some studies.13 , 23 This was the wavelength used in the present study, following the manufacturer's recommendations. However, even the use of laser with wavelength at 830 nm has yielded discrepant results, with LLLT producing some analgesic effect,14 despite not being significant.6 According to the manufacturer's instructions, we used, in this study, 6 J of energy in a single dose. Other similar studies used from 5 to 12 J of energy in single or daily applications. One single application seems more practical, as it does not rely on further appointments and patient cooperation.19. Although the amount of energy probably influences the analgesic effect, some studies report LLLT efficacy19 - 22 or not6 , 18 with similar energy and frequency levels. Further studies can clarify this point. A systematic review has recently reported that nonsteroidal anti-inflammatory drugs (NSAIDs), such as COX-2 selective inhibitor, are still the best choice to reduce pain during orthodontic treatment, despite potential side effects.15 Another recent study revealed that a single dose of Piroxicam, taken 60 minutes before separator placement, reduces pain.24 Since patients generally perceive pain as mild and transient, an analgesic regimen should only be adopted for less tolerant patients. However, should such regimen prove necessary, a single application of LLLT does not seem to provide a fully effective protocol for this purpose.

CONCLUSION

A single application (6 J) of LLLT (808 nm) did not produce significant effects on the perception of pain caused by orthodontic separation. Overall, pain arising from the use of orthodontic pre-banding elastomeric separators was low and transient, and discomfort was reported as relevant only by a minority of patients (18% in this study).
  21 in total

1.  Pain relief by single low-level laser irradiation in orthodontic patients undergoing fixed appliance therapy.

Authors:  Dritan Turhani; Martina Scheriau; David Kapral; Thomas Benesch; Erwin Jonke; Hans Peter Bantleon
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-09       Impact factor: 2.650

2.  The pain experience and psychological adjustment to orthodontic treatment of preadolescents, adolescents, and adults.

Authors:  D F Brown; R G Moerenhout
Journal:  Am J Orthod Dentofacial Orthop       Date:  1991-10       Impact factor: 2.650

3.  Efficacy of low-intensity laser therapy in reducing treatment time and orthodontic pain: a clinical investigation.

Authors:  Gauri Doshi-Mehta; Wasundhara A Bhad-Patil
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-03       Impact factor: 2.650

4.  Attitudes to orthodontic treatment.

Authors:  R G Oliver; Y M Knapman
Journal:  Br J Orthod       Date:  1985-10

5.  Stimulatory effects of low-power laser irradiation on bone regeneration in midpalatal suture during expansion in the rat.

Authors:  S Saito; N Shimizu
Journal:  Am J Orthod Dentofacial Orthop       Date:  1997-05       Impact factor: 2.650

6.  Perception of discomfort by patients undergoing orthodontic treatment.

Authors:  P Ngan; B Kess; S Wilson
Journal:  Am J Orthod Dentofacial Orthop       Date:  1989-07       Impact factor: 2.650

7.  Inhibition of prostaglandin E2 and interleukin 1-beta production by low-power laser irradiation in stretched human periodontal ligament cells.

Authors:  N Shimizu; M Yamaguchi; T Goseki; Y Shibata; H Takiguchi; T Iwasawa; Y Abiko
Journal:  J Dent Res       Date:  1995-07       Impact factor: 6.116

8.  Clinical effect of CO(2) laser in reducing pain in orthodontics.

Authors:  Koji Fujiyama; Toru Deguchi; Takashi Murakami; Akihito Fujii; Kazuhiko Kushima; Teruko Takano-Yamamoto
Journal:  Angle Orthod       Date:  2008-03       Impact factor: 2.079

9.  Effect of frequent laser irradiation on orthodontic pain. A single-blind randomized clinical trial.

Authors:  Won Tae Kim; Mohamed Bayome; Jun-Beom Park; Jae Hyun Park; Seung-Hak Baek; Yoon-Ah Kook
Journal:  Angle Orthod       Date:  2012-12-14       Impact factor: 2.079

10.  Effect of low-level laser therapy on dental pain induced by separator force in orthodontic treatment.

Authors:  Seyed Mostafa Abtahi; Seyed Amir Mousavi; Hooman Shafaee; Behrad Tanbakuchi
Journal:  Dent Res J (Isfahan)       Date:  2013-09
View more
  10 in total

1.  Efficacy of Photobiomodulation Therapy for Orthodontic Pain Control Following the Placement of Elastomeric Separators: A Randomized Clinical Trial.

Authors:  AmirHossein Mirhashemi; Seyedreza Rasouli; Shiva Shahi; Nasim Chiniforush
Journal:  J Lasers Med Sci       Date:  2021-02-22

2.  Under the spotlight: mechanisms of photobiomodulation concentrating on blue and green light.

Authors:  Hannah Serrage; Vladimir Heiskanen; William M Palin; Paul R Cooper; Michael R Milward; Mohammed Hadis; Michael R Hamblin
Journal:  Photochem Photobiol Sci       Date:  2019-06-11       Impact factor: 3.982

3.  Clinical study on the efficacy of LED phototherapy for pain control in an orthodontic procedure.

Authors:  I Z Figueira; A P C Sousa; A W Machado; F A L Habib; L G P Soares; A L B Pinheiro
Journal:  Lasers Med Sci       Date:  2018-08-18       Impact factor: 3.161

4.  Evaluation of Low Level Laser Therapy on Pain Perception Following Orthodontic Elastomeric Separation: A Randomized Controlled Trial.

Authors:  Mai M E Almallah; Wael H Almahdi; Mohammad Y Hajeer
Journal:  J Clin Diagn Res       Date:  2016-11-01

Review 5.  The Effectiveness of Low-Level Laser Therapy in Pain Induced by Orthodontic Separator Placement: A Systematic Review.

Authors:  Arash Farzan; Katayoon Khaleghi
Journal:  J Lasers Med Sci       Date:  2021-06-24

Review 6.  Effectiveness of Low-Level Laser Therapy in Reducing Orthodontic Pain: A Systematic Review and Meta-Analysis.

Authors:  Naira Figueiredo Deana; Carlos Zaror; Paulo Sandoval; Nilton Alves
Journal:  Pain Res Manag       Date:  2017-09-27       Impact factor: 3.037

7.  Evaluation of Low-Level Laser Therapy on Orthodontic Tooth Movement: A Randomized Control Study.

Authors:  Guneet Guram; Rajesh Kumar Reddy; Anand M Dharamsi; Prabhu Mahin Syed Ismail; Samvit Mishra; M Dave Prakashkumar
Journal:  Contemp Clin Dent       Date:  2018 Jan-Mar

8.  Photobiomodulation and Pain Reduction in Patients Requiring Orthodontic Band Application: Randomized Clinical Trial.

Authors:  Maria Francesca Sfondrini; Marina Vitale; Antonio Luiz Barbosa Pinheiro; Paola Gandini; Lorenzo Sorrentino; Ugo Matteo Iarussi; Andrea Scribante
Journal:  Biomed Res Int       Date:  2020-05-25       Impact factor: 3.411

9.  Separation and pain perception of Elastomeric, Kesling and Kansal separators.

Authors:  Tulika Tripathi; Navneet Singh; Priyank Rai; Neha Khanna
Journal:  Dental Press J Orthod       Date:  2019-05-20

10.  Laser-Assisted Orthodontic Tooth Movement in Saudi Population: A Prospective Clinical Intervention of Low-Level Laser Therapy in the 1st Week of Pain Perception in Four Treatment Modalities.

Authors:  Mohammad Khursheed Alam
Journal:  Pain Res Manag       Date:  2019-10-20       Impact factor: 3.037

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.