Mohammad Hosseinifar1, Asghar Akbari, Fateme Ghiasi.
Abstract
INTRODUCTION: Rehabilitative Ultrasound Imaging (RUSI) must be valuable method for research and rehabilitation. So, the reliability of its measurements must be determined. The purpose of this study was to evaluate the intra-rater reliability of RUSI for measurement of multifidus (MF) muscles cross section areas (CSAs), bladder wall diameter, and thickness of MF muscles between 2 sessions in healthy subjects.Entities:
Mesh:
Year: 2015 PMID: 26153153 PMCID: PMC4803889 DOI: 10.5539/gjhs.v7n6p354
Source DB: PubMed Journal: Glob J Health Sci ISSN: 1916-9736
Demographic characteristics of subjects
| Mean and Standard Deviation | Range | |
|---|---|---|
| 27.06±6.80[ | 22-42 | |
| 170.93±8.60 | 161-195 | |
| 65.69±7.23 | 55.6-75.5 | |
| 22.50±2.16 | 19.46-24.84 |
BMI= body mass index,
Values are Means and Standard Deviation
Intra- Rater Reliability of the variables
| Repeat 1 | Repeat 2 | Intra-class Correlation Coefficient | 95% Confidence Interval | SEM[ | SEM[ | |||
|---|---|---|---|---|---|---|---|---|
| Lower Bound | Upper Bound | |||||||
| Rest | 40.20±15.76[ | 38.03±13.65 | 0.961 | -0.623 | 4.961 | 4.37 | 3.78 | |
| Cont | 35.52±16.82 | 34.65±13.97 | 0.958 | -2.327 | 4.065 | 4.66 | 3.87 | |
| Rt | 85.20±20.19 | 88.23±22.59 | 0.744 | -12.367 | 6.321 | 5.60 | 6.26 | |
| Lt | 78.99±22.59 | 82.89±19.28 | 0.911 | -9.590 | 1.790 | 6.26 | 5.35 | |
| Rt | 29.87±4.79 | 30.68±5.64 | 0.84 | -1.76 | 0.134 | 0.74 | 0.87 | |
| Lt | 29.23±6.80 | 31.20±6.33 | 0.67 | -3.64 | -0.297 | 1.05 | 0.98 | |
| Rt | 29.25±4.25 | 30.47±4.21 | 0.68 | -2.26 | -0.166 | 0.65 | 0.65 | |
| Lt | 29.82±4.09 | 30.58±4.18 | 0.66 | -1.82 | 0.303 | 0.63 | 0.65 | |
Values are Means and Standard Deviation.
Standard Error of Measurement, Repeat 1
Standard Error of Measurement, Repeat 2
Intra- Rater Reliability of the variables
| Repeat 1 | Repeat 2 | Intra-class Correlation Coefficient | 95% Confidence Interval | SEM[ | SEM[ | |||
|---|---|---|---|---|---|---|---|---|
| Lower Bound | Upper Bound | |||||||
| Rt | 33.92±5.56[ | 34.64±5.94 | 0.85 | -1.53 | 0.459 | 0.86 | 0.92 | |
| Lt | 34.75±6.01 | 35.73±6.08 | 0.87 | -1.94 | -0.026 | 0.93 | 0.94 | |
| Rt | 33.61±4.47 | 34.74±4.34 | 0.81 | -1.96 | -0.285 | 0.69 | 0.67 | |
| Lt | 35.21±4.16 | 35.84±4.44 | 0.74 | -1.60 | 0.352 | 0.64 | 0.68 | |
| Rt | 34.82±5.65 | 35.69±5.29 | 0.84 | -1.84 | 0.109 | 0.87 | 0.82 | |
| Lt | 35.81±5.32 | 36.80±6.24 | 0.84 | -2.05 | 0.064 | 0.82 | 0.96 | |
| Rt | 35.37±4.30 | 36.32±4.42 | 0.64 | -2.12 | 0.204 | 0.66 | 0.68 | |
| Lt | 35.78±4.13 | 37.02±4.69 | 0.72 | -2.291 | -0.189 | 0.64 | 0.72 | |
Task 1= Arm elevation with glenohumeral joint at 125 degree of abduction and elbow at right angle, without weight at hand, Task 2= Arm elevation with glenohumeral joint at 125 degree of abduction and elbow at right angle, with weight (0.5 kg) at hand,
Values are Means and Standard Deviation,
Standard Error of Measurement, Repeat 1,
Standard Error of Measurement, Repeat 2.