Literature DB >> 26148576

Useful surface parameters for biomaterial discrimination.

Marina Etxeberria1, Tomas Escuin2, Miquel Vinas3, Carlos Ascaso4.   

Abstract

Topographical features of biomaterials' surfaces are determinant when addressing their application site. Unfortunately up to date there has not been an agreement regarding which surface parameters are more representative in discriminating between materials. Discs (n = 16) of different currently used materials for implant prostheses fabrication, such as cast cobalt-chrome, direct laser metal soldered (DLMS) cobalt-chrome, titanium grade V, zirconia (Y-TZP), E-glass fiber-reinforced composite and polyetheretherketone (PEEK) were manufactured. Nanoscale topographical surface roughness parameters generated by atomic force microscopy (AFM), microscale surface roughness parameters obtained by white light interferometry (WLI) and water angle values obtained by the sessile-water-drop method were analyzed in order to assess which parameter provides the best optimum surface characterization method. Correlations between nanoroughness, microroughness, and hydrophobicity data were performed to achieve the best parameters giving the highest discriminatory power. A subset of six parameters for surface characterization were proposed. AFM and WLI techniques gave complementary information. Wettability did not correlate with any of the nanoroughness parameters while it however showed a weak correlation with microroughness parameters. © Wiley Periodicals, Inc.

Entities:  

Keywords:  AFM; biomaterial; surface characterization; wettability; white light interferometry

Mesh:

Substances:

Year:  2015        PMID: 26148576     DOI: 10.1002/sca.21232

Source DB:  PubMed          Journal:  Scanning        ISSN: 0161-0457            Impact factor:   1.932


  4 in total

1.  Is the re-use of sterilized implant abutments safe enough? (Implant abutment safety).

Authors:  M-A Sánchez-Garcés; M Jorba; J Ciurana; M Vinas; M-T Vinuesa
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2019-09-01

2.  Surface roughness and chemical composition changes of resin-modified glass ionomer immersed in 0.2% sodium fluoride solution.

Authors:  Seung-Hwan Ong; Seung-Hoon Yoo
Journal:  J Dent Sci       Date:  2020-08-28       Impact factor: 2.080

Review 3.  Two-Process Random Textures: Measurement, Characterization, Modeling and Tribological Impact: A Review.

Authors:  Pawel Pawlus; Rafal Reizer; Wieslaw Żelasko
Journal:  Materials (Basel)       Date:  2021-12-30       Impact factor: 3.623

4.  Acid Resistance of CAD/CAM Resin Composites.

Authors:  Leonie Schmohl; Anuschka Josephine Roesner; Florian Fuchs; Maximilian Wagner; Michael Benno Schmidt; Sebastian Hahnel; Angelika Rauch; Andreas Koenig
Journal:  Biomedicines       Date:  2022-06-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.