Literature DB >> 26148526

Improved Differential Ion Mobility Separations Using Linked Scans of Carrier Gas Composition and Compensation Field.

Brandon G Santiago1, Rachel A Harris1, Samantha L Isenberg1, Mark E Ridgeway1, Alice L Pilo1, Desmond A Kaplan2, Gary L Glish3.   

Abstract

Differential ion mobility spectrometry (DIMS) separates ions based on differences in their mobilities in low and high electric fields. When coupled to mass spectrometric analyses, DIMS has the ability to improve signal-to-background by eliminating isobaric and isomeric compounds for analytes in complex mixtures. DIMS separation power, often measured by resolution and peak capacity, can be improved through increasing the fraction of helium in the nitrogen carrier gas. However, because the mobility of ions is higher in helium, a greater number of ions collide with the DIMS electrodes or housing, yielding losses in signal intensity. To take advantage of the benefits of helium addition on DIMS separations and reduce ion losses, linked scans were developed. In a linked scan the helium content of the carrier gas is reduced as the compensation field is increased. Linked scans were compared with conventional compensation field scans with constant helium content for the protein ubiquitin and a tryptic digest of bovine serum albumin (BSA). Linked scans yield better separation of ubiquitin charge states and enhanced peak capacities for the analysis of BSA compared with compensation field scans with constant helium carrier gas percentages. Linked scans also offer improved signal intensity retention in comparison to compensation field scans with constant helium percentages in the carrier gas.

Entities:  

Keywords:  Carrier gas; DIMS; Differential ion mobility spectrometry; FAIMS; Mass spectrometry; Peak capacity

Year:  2015        PMID: 26148526     DOI: 10.1007/s13361-015-1208-9

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  18 in total

1.  Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas.

Authors:  G A Eiceman; E V Krylov; N S Krylova; E G Nazarov; R A Miller
Journal:  Anal Chem       Date:  2004-09-01       Impact factor: 6.986

2.  Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS).

Authors:  Beata M Kolakowski; Zoltán Mester
Journal:  Analyst       Date:  2007-06-26       Impact factor: 4.616

3.  Scaling of the resolving power and sensitivity for planar FAIMS and mobility-based discrimination in flow- and field-driven analyzers.

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  J Am Soc Mass Spectrom       Date:  2007-06-30       Impact factor: 3.109

4.  LC-FAIMS-MS/MS for quantification of a peptide in plasma and evaluation of FAIMS global selectivity from plasma components.

Authors:  Yuan-Qing Xia; Steven T Wu; Mohammed Jemal
Journal:  Anal Chem       Date:  2008-07-25       Impact factor: 6.986

5.  Selection and generation of waveforms for differential mobility spectrometry.

Authors:  Evgeny V Krylov; Stephen L Coy; John Vandermey; Bradley B Schneider; Thomas R Covey; Erkinjon G Nazarov
Journal:  Rev Sci Instrum       Date:  2010-02       Impact factor: 1.523

6.  Understanding and designing field asymmetric waveform ion mobility spectrometry separations in gas mixtures.

Authors:  Alexandre A Shvartsburg; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2004-12-15       Impact factor: 6.986

7.  Ultrahigh-resolution differential ion mobility spectrometry using extended separation times.

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  Anal Chem       Date:  2010-11-30       Impact factor: 6.986

8.  Chemical effects in the separation process of a differential mobility/mass spectrometer system.

Authors:  Bradley B Schneider; Thomas R Covey; Stephen L Coy; Evgeny V Krylov; Erkinjon G Nazarov
Journal:  Anal Chem       Date:  2010-03-01       Impact factor: 6.986

9.  Effect of moisture on the field dependence of mobility for gas-phase ions of organophosphorus compounds at atmospheric pressure with field asymmetric ion mobility spectrometry.

Authors:  N Krylova; E Krylov; G A Eiceman; J A Stone
Journal:  J Phys Chem A       Date:  2003-05-15       Impact factor: 2.781

10.  Fundamentals of traveling wave ion mobility spectrometry.

Authors:  Alexandre A Shvartsburg; Richard D Smith
Journal:  Anal Chem       Date:  2008-12-15       Impact factor: 6.986

View more
  3 in total

1.  Variables Affecting the Internal Energy of Peptide Ions During Separation by Differential Ion Mobility Spectrometry.

Authors:  Brandon G Santiago; Matthew T Campbell; Gary L Glish
Journal:  J Am Soc Mass Spectrom       Date:  2017-06-26       Impact factor: 3.109

2.  Correlating Resolving Power, Resolution, and Collision Cross Section: Unifying Cross-Platform Assessment of Separation Efficiency in Ion Mobility Spectrometry.

Authors:  James N Dodds; Jody C May; John A McLean
Journal:  Anal Chem       Date:  2017-10-30       Impact factor: 6.986

3.  Analyzing Glycopeptide Isomers by Combining Differential Mobility Spectrometry with Electron- and Collision-Based Tandem Mass Spectrometry.

Authors:  J Larry Campbell; Takashi Baba; Chang Liu; Catherine S Lane; J C Yves Le Blanc; James W Hager
Journal:  J Am Soc Mass Spectrom       Date:  2017-04-21       Impact factor: 3.109

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.