Literature DB >> 26140989

Incorporation of electrochemical advanced oxidation processes in a multistage treatment system for sanitary landfill leachate.

Francisca C Moreira1, J Soler2, Amélia Fonseca3, Isabel Saraiva3, Rui A R Boaventura2, Enric Brillas4, Vítor J P Vilar5.   

Abstract

The current study has proved the technical feasibility of including electrochemical advanced oxidation processes (EAOPs) in a multistage strategy for the remediation of a sanitary landfill leachate that embraced: (i) first biological treatment to remove the biodegradable organic fraction, oxidize ammonium and reduce alkalinity, (ii) coagulation of the bio-treated leachate to precipitate humic acids and particles, followed by separation of the clarified effluent, and (iii) oxidation of the resulting effluent by an EAOP to degrade the recalcitrant organic matter and increase its biodegradability so that a second biological process for removal of biodegradable organics and nitrogen content could be applied. The influence of current density on an UVA photoelectro-Fenton (PEF) process was firstly assessed. The oxidation ability of various EAOPs such as electro-Fenton (EF) with two distinct initial total dissolved iron concentrations ([TDI]0), PEF and solar PEF (SPEF) was further evaluated and these processes were compared with their analogous chemical ones. A detailed assessment of the two first treatment stages was made and the biodegradability enhancement during the SPEF process was determined by a Zahn-Wellens test to define the ideal organics oxidation state to stop the EAOP and apply the second biological treatment. The best current density was 200 mA cm(-2) for a PEF process using a BDD anode, [TDI]0 of 60 mg L(-1), pH 2.8 and 20 °C. The relative oxidation ability of EAOPs increased in the order EF with 12 mg [TDI]0 L(-1) < EF with 60 mg [TDI]0 L(-1) < PEF with 60 mg [TDI]0 L(-1) ≤ SPEF with 60 mg [TDI]0 L(-1), using the abovementioned conditions. While EF process was much superior to the Fenton one, the superiority of PEF over photo-Fenton was less evident and SPEF attained similar degradation to solar photo-Fenton. To provide a final dissolved organic carbon (DOC) of 163 mg L(-1) to fulfill the discharge limits into the environment after a second biological process, 6.2 kJ L(-1) UV energy and 36 kWh m(-3) electrical energy were consumed using SPEF with a BDD anode at 200 mA cm(-2), 60 mg [TDI]0 L(-1), pH 2.8 and 20 °C.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biodegradability enhancement; Biological treatment; Coagulation; EAOPs; Sanitary landfill leachate

Mesh:

Substances:

Year:  2015        PMID: 26140989     DOI: 10.1016/j.watres.2015.05.036

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  4 in total

1.  Application of TiO2-organobentonite modified by cetyltrimethylammonium chloride photocatalyst and polyaluminum chloride coagulant for pretreatment of aging landfill leachate.

Authors:  Yi-Jie Zhang; Zhao-Hui Yang; Pei-Pei Song; Hai-Yin Xu; Rui Xu; Jing Huang; Juan Li; Yan Zhou
Journal:  Environ Sci Pollut Res Int       Date:  2016-06-13       Impact factor: 4.223

2.  Adsorptive performance of coal-based magnetic activated carbon for cyclic volatile methylsiloxanes from landfill leachate.

Authors:  Chunhui Zhang; Shan Jiang; Wenwen Zhang
Journal:  Environ Sci Pollut Res Int       Date:  2017-12-03       Impact factor: 4.223

3.  Simultaneous Desalination and Removal of Recalcitrant Organics from Reverse Osmosis Leachate Concentrate by Electrochemical Oxidation.

Authors:  Chaoqun Yan; Yijuan Tian; Zhiliang Cheng; Zejun Wei; Xuan Zhang; Xuejun Quan
Journal:  ACS Omega       Date:  2021-06-11

Review 4.  Graphitic nitride-catalyzed advanced oxidation processes (AOPs) for landfill leachate treatment: A mini review.

Authors:  Meina Han; Xiaoguang Duan; Guoliang Cao; Shishu Zhu; Shih-Hsin Ho
Journal:  Process Saf Environ Prot       Date:  2020-05-05       Impact factor: 6.158

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.