| Literature DB >> 26139738 |
Biju Sivam Pillai, Kanwar Aditya Baloria1, Nandini Selot.
Abstract
AIMS ANDEntities:
Mesh:
Year: 2015 PMID: 26139738 PMCID: PMC4881706 DOI: 10.4103/0971-9784.159803
Source DB: PubMed Journal: Ann Card Anaesth ISSN: 0971-9784
Figure 1Patient population risk stratified
Breakup of procedure wise mortality
| Types of procedures | Number of deaths |
|---|---|
| Off-pump CABG | 8 |
| On-pump CABG | 10 |
| Bentall | 0 |
| AVR | 2 |
| DVR | 0 |
| MVR | 2 |
| CABG+MVR | 2 |
| CABG+AVR | 3 |
| CABG+CEA | 1 |
| MVR+TV repair | 0 |
| Post-MI VSD repair | 4 |
CABG: Coronary artery bypass grafting, AVR: Aortic valve replacement, DVR: Double valve replacement, MVR: MV replacement, MV: Mitral valve, CEA: Carotid endarterectomy, VSD: Ventricular septal defect, MI: Myocardial infarction, TV: Tricuspid valve
Figure 2Observed and predicted mortality in all cases
Risk factors causing mortality
| Variables | |
|---|---|
| Creatinine | 0.017 |
| Peripheral vascular disease | 0.017 |
| Pulmonary artery hypertension | <0.0001 |
| Ejection fraction<30% | 0.001 |
| Low cardiac output | <0.0001 |
| Preoperative IABP | <0.0001 |
| Types of operation | 0.001 |
IABP: Intra-aortic balloon pump
Figure 3Receiver operating characteristics curve for all four scoring systems plotting all causes mortality
Figure 4Receiver operating characteristics curves comparing various scoring systems in valve surgery patients
Area under the curve of mortality of all scoring systems
| Area under the curve | |
|---|---|
| Test result variable | Area |
| Euro II | 0.736 |
| Cleveland | 0.767 |
| Parsonnet | 0.689 |
| System-97 | 0.775 |
Area under the curves comparing various scoring systems in valve surgery patients
| Area under the curve | |
|---|---|
| Test result variable | Area |
| Euro II | 0.630 |
| Cleveland | 0.717 |
| Parsonnet | 0.639 |
| System-97 | 0.717 |