Literature DB >> 26138831

Comparison between Plain Old Balloon Angioplasty and Drug-Eluting Stent Implantation for the Treatment of Stent Fracture.

Satoru Mitomo1, Toru Naganuma1, Kensuke Takagi1, Charis Costopoulos2, Shotaro Nakamura1, Koji Hozawa1, Naoyuki Kurita1, Satoko Tahara1, Hisaaki Ishiguro1, Sunao Nakamura1.   

Abstract

OBJECTIVES: The aim of this study was to evaluate clinical outcomes after percutaneous coronary intervention (PCI) for stent fracture (SF).
BACKGROUND: SF has been reported as a predictor of in-stent restenosis (ISR) and stent thrombosis (ST).
METHODS: Between January 2009 and December 2012, consecutive SF cases treated with either drug-eluting stent (DES) or plain old balloon angioplasty (POBA) were retrospectively enrolled in this study. The study endpoints were all-cause death, cardiac death, myocardial infarction (MI), target vessel revascularization (TVR), target lesion revascularization (TLR), ST, re-stent fracture (re-SF), and major adverse cardiac events (MACE) defined as the composite of cardiac death, MI, and TLR.
RESULTS: Of 135 SF cases, 67 (49.6%) cases were treated with DES, whereas 68 (50.4%) cases with POBA. Median follow-up period was 1,401 (IQR: 967-1,771) days. The estimated MACE rate at 3 years was significantly lower in the DES group as compared with the POBA group largely driven by less TLR (25.7 vs. 55.8%, P < 0.001). Moreover, 1-year landmark analysis after PCI for SF revealed that MACE continued to occur even after 1 year irrespective of the treatment option (P = 0.47). On multivariable Cox regression analysis, POBA and large post-procedure angle (Δ) defined as the degree difference between the end systolic and diastolic angle were identified as independent predictors for TLR.
CONCLUSIONS: DES implantation for SF is associated with better clinical outcomes as compared to POBA alone, due to a lower need for TLR. Large post-procedural angle (Δ) appears to be an independent predictor of TLR.
© 2015, Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2015        PMID: 26138831     DOI: 10.1111/joic.12215

Source DB:  PubMed          Journal:  J Interv Cardiol        ISSN: 0896-4327            Impact factor:   2.279


  1 in total

1.  An Interesting Case and Literature Review of a Coronary Stent Fracture in a Current Generation Platinum Chromium Everolimus-Eluting Stent.

Authors:  Sammy San Myint Aung; Htun Latt; Kyaw Kyaw; Chanwit Roongsritong
Journal:  Case Rep Cardiol       Date:  2018-06-04