Linear and nonlinear one-dimensional models of pulse wave transmission at high Womersley numbers.

P J Reuderink1, H W Hoogstraten, P Sipkema, B Hillen, N Westerhof.   

Abstract

The accuracy of nonlinear and linear one-dimensional models in describing pulse wave propagation in a uniform cylindrical viscoelastic tube, with Womersley's parameter alpha equal to 7.6 at 1 Hz, was evaluated. To this end calculations of wave propagation using these models were compared with the experimentally determined propagation of the pressure wave in the tube. The experimentally generated pressure pulse had an amplitude of 9.0 kPa and caused a relative radius change of about 17%. The static pressure vs cross-sectional area relation was found to be nonlinear for these pressure changes. Maximum fluid velocity was about 2.9 ms-1, while the phase velocity was about 5.4 ms-1. The radius change and the ratio of fluid and phase velocities violated the linear model assumptions. The nonlinear model with viscous fluid friction modelled on the basis of Poiseuille's law and treating the tube wall as purely elastic, underestimated the damping of the pulse wave and predicted the formation of shock waves, which were not found experimentally. In the linear models, the viscous friction of the blood was modelled according to either Poiseuille's law or Womersley's theory and the tube wall was treated as either linearly elastic or linearly viscoelastic. A description of the viscous friction of the blood based on Poiseuille's law underestimated damping. Disregarding the viscoelasticity of the tube wall resulted in an underestimation of both phase velocity and damping. In spite of the nonlinearity of the system, the linear viscoelastic Womersley model described the pulse wave propagation satisfactorily.

Entities:  

Mesh:

Year:  1989        PMID: 2613717     DOI: 10.1016/0021-9290(89)90065-1

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  A mathematical model of flow in a liquid-filled visco-elastic tube.

Authors:  G Pontrelli
Journal:  Med Biol Eng Comput       Date:  2002-09       Impact factor: 2.602

2.  Isolated aorta setup for hemodynamic studies.

Authors:  P Sipkema; R D Latham; N Westerhof; B J Rubal; D M Slife
Journal:  Ann Biomed Eng       Date:  1990       Impact factor: 3.934

3.  Assessment of distributed arterial network models.

Authors:  P Segers; N Stergiopulos; P Verdonck; R Verhoeven
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

4.  Wave propagation with different pressure signals: an experimental study on the latex tube.

Authors:  M Ursino; E Artioli; M Gallerani
Journal:  Med Biol Eng Comput       Date:  1993-07       Impact factor: 2.602

5.  Uncertainty Quantification in a Patient-Specific One-Dimensional Arterial Network Model: EnKF-Based Inflow Estimator.

Authors:  Andrea Arnold; Christina Battista; Daniel Bia; Yanina Zócalo German; Ricardo L Armentano; Hien Tran; Mette S Olufsen
Journal:  J Verif Valid Uncertain Quantif       Date:  2017-02-22

6.  Influence of the distensibility of large arteries on the longitudinal impedance: application for the development of non-invasive techniques to the diagnosis of arterial diseases.

Authors:  Ridha Ben Salah; Wassila Sahtout
Journal:  Nonlinear Biomed Phys       Date:  2012-04-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.