Yves Young1, Parirash Abdolhosseini, Freddy Brown, James Faulkner, Danielle Lambrick, Michelle A Williams, Lee Stoner. 1. aDepartment of Epidemiology, Harvard School of Public Health, Boston, Massachusetts, USA bSchool of Sport and Exercise, Massey University, Wellington, New Zealand cDepartment of Sport and Exercise, University of Winchester, Winchester dFaculty of Health Sciences, University of Southampton, Southampton, Hampshire, UK.
Abstract
OBJECTIVE: Oscillometric pulse wave analysis devices have recently emerged, presenting suitable options for investigating central hemodynamic properties in clinical practice. This study sought to examine whether the between-day reliability of central SBP (cSBP) and systemic arterial wave reflection (augmentation index, AIx) readings exceed the criterion for acceptable reliability or are affected by posture (supine and seated) and fasting state. METHODS: Twenty healthy adults (50% female, 27.9 years, 24.2 kg/m) were tested on six different mornings: 3 days fasted and 3 days nonfasted. On each occasion, participants were tested in supine and seated postures. Oscillometric pressure waveforms were recorded on left upper arm. RESULTS: For cSBP, there was nonsignificant main effect for fasting state (P = 0.819) but there was a main effect for posture (P = 0.002). Conversely, for AIx, there was nonsignificant main effect for posture (P = 0.537) but there was a large main effect for fasting state (P = < 0.001). The criterion intraclass correlation coefficient value of 0.75 was exceeded for both variables when participants were assessed under the combined supine-fasted condition. For cSBP, the reliability coefficient was lowest (best) when supine fasted (6.8 mmHg) and greatest (worst) when seated nonfasted (8.6 mmHg). For AIx, the reliability coefficient was lower for the supine (11.4-11.7%) compared with the seated (14.0-15.2%) posture. CONCLUSION: Findings from this study suggest that oscillometric assessments of central hemodynamic variables exceed the criterion for acceptable reliability and are most reliable when participants are evaluated while supine and fasted.
OBJECTIVE: Oscillometric pulse wave analysis devices have recently emerged, presenting suitable options for investigating central hemodynamic properties in clinical practice. This study sought to examine whether the between-day reliability of central SBP (cSBP) and systemic arterial wave reflection (augmentation index, AIx) readings exceed the criterion for acceptable reliability or are affected by posture (supine and seated) and fasting state. METHODS: Twenty healthy adults (50% female, 27.9 years, 24.2 kg/m) were tested on six different mornings: 3 days fasted and 3 days nonfasted. On each occasion, participants were tested in supine and seated postures. Oscillometric pressure waveforms were recorded on left upper arm. RESULTS: For cSBP, there was nonsignificant main effect for fasting state (P = 0.819) but there was a main effect for posture (P = 0.002). Conversely, for AIx, there was nonsignificant main effect for posture (P = 0.537) but there was a large main effect for fasting state (P = < 0.001). The criterion intraclass correlation coefficient value of 0.75 was exceeded for both variables when participants were assessed under the combined supine-fasted condition. For cSBP, the reliability coefficient was lowest (best) when supine fasted (6.8 mmHg) and greatest (worst) when seated nonfasted (8.6 mmHg). For AIx, the reliability coefficient was lower for the supine (11.4-11.7%) compared with the seated (14.0-15.2%) posture. CONCLUSION: Findings from this study suggest that oscillometric assessments of central hemodynamic variables exceed the criterion for acceptable reliability and are most reliable when participants are evaluated while supine and fasted.
Authors: Lee Stoner; Keeron Stone; Gabriel Zieff; EriK D Hanson; Daniel Credeur; James Faulkner; Anna Kucharska-Newton; Simon Fryer Journal: J Hum Hypertens Date: 2019-02-25 Impact factor: 3.012
Authors: Alexander Pomeroy; Lauren C Bates; Lee Stoner; Mark A Weaver; Justin B Moore; Svetlana Nepocatych; Simon Higgins Journal: Transl J Am Coll Sports Med Date: 2022-04-07
Authors: James Faulkner; Louis Martinelli; Kirsty Cook; Lee Stoner; Helen Ryan-Stewart; Eloise Paine; Helen Hobbs; Danielle Lambrick Journal: J Spinal Cord Med Date: 2019-09-16 Impact factor: 1.985
Authors: Yasmina Serinel; Camilla Hoyos; Ahmad Qasem; Brendon J Yee; Ronald R Grunstein; Keith H Wong; Craig L Phillips Journal: Int J Cardiol Hypertens Date: 2019-04-09
Authors: Paulo Farinatti; Alex da Silva Itaborahy; Tainah de Paula; Walace David Monteiro; Mário F Neves Journal: Sci Rep Date: 2021-01-12 Impact factor: 4.379
Authors: Lee Stoner; David Rowlands; Ariel Morrison; Daniel Credeur; Michael Hamlin; Kim Gaffney; Danielle Lambrick; Anna Matheson Journal: Sports Med Date: 2016-11 Impact factor: 11.136
Authors: J Faulkner; Y-C Tzeng; D Lambrick; B Woolley; P D Allan; T O'Donnell; J Lanford; L Wong; L Stoner Journal: J Hum Hypertens Date: 2016-09-29 Impact factor: 3.012
Authors: Lee Stoner; Mark Weatherall; Paula Skidmore; Nicholas Castro; Sally Lark; James Faulkner; Michelle A Williams Journal: J Am Heart Assoc Date: 2017-10-11 Impact factor: 5.501
Authors: Andrew Mitchelmore; Lee Stoner; Danielle Lambrick; Lucy Sykes; Charlotte Eglinton; Simon Jobson; James Faulkner Journal: PLoS One Date: 2018-11-01 Impact factor: 3.240