Literature DB >> 26135063

Ultrasound Imaging Reduces Failure Rates of Percutaneous Central Venous Catheterization in Children.

Nobuaki Shime1, Koji Hosokawa, Graeme MacLaren.   

Abstract

OBJECTIVE: Ultrasound imaging has been shown to be beneficial for percutaneous central venous cannulation in systematic reviews of randomized controlled trials in adult patients, but not in pediatrics. The aim of this updated review was to determine whether percutaneous central venous catheterization with the aid of ultrasound reduces cannulation failure in children. DATA SOURCES: PubMed was searched using the terms: ultrasound, catheterization, central vein (including internal jugular and femoral veins), and pediatrics. STUDY SELECTION: Both nonrandomized comparative studies and randomized controlled trials were eligible for inclusion if they assessed the rate of cannulation failure using real-time, dynamic ultrasound guidance, ultrasound-assisted vein prelocation, and/or anatomic landmark technique. DATA EXTRACTION: Five nonrandomized studies and nine randomized controlled trials were included. The rates of cannulation failure and arterial puncture were retrieved. DATA SYNTHESIS: Random-effects meta-analysis was applied.
CONCLUSIONS: The meta-analysis of five nonrandomized studies showed that the rate of cannulation failure was significantly lower with real-time ultrasound guidance than anatomic landmark technique (odds ratio, 0.44 [95% CI, 0.27-0.72]; p = 0.001). The combination of nine randomized controlled trials also showed lower failure rates with either the real-time ultrasound guidance or the prelocation technique over the landmark technique (odds ratio, 0.22 [95% CI, 0.07-0.69]; p = 0.0003) and fewer arterial punctures in the ultrasound group (odds ratio, 0.31 [95% CI, 0.09-1.08]; p = 0.07). However, seven out of nine studies were assessed as having high risk of bias. Since the lower cannulation failure and less frequent chance of arterial puncture with ultrasound were predominantly shown in studies at high risk of bias, further definitive and adequately powered studies with clear outcomes are needed.

Entities:  

Mesh:

Year:  2015        PMID: 26135063     DOI: 10.1097/PCC.0000000000000470

Source DB:  PubMed          Journal:  Pediatr Crit Care Med        ISSN: 1529-7535            Impact factor:   3.624


  7 in total

1.  The Effect of Clinical Experience on the Learning Curve of Pediatric Intensive Care Unit Residents for the Central Venous Catheter Placement Procedure.

Authors:  Norihiko Tsuboi; Michiko Abe; Shotaro Matsumoto; Nao Nishimura; Satoshi Nakagawa
Journal:  J Pediatr Intensive Care       Date:  2017-07-06

Review 2.  [Avoidance of complications when dealing with central venous catheters in the treatment of children].

Authors:  D Aprili; T O Erb
Journal:  Anaesthesist       Date:  2017-04       Impact factor: 1.041

3.  Ultrasound-guided or landmark techniques for central venous catheter placement in critically ill children.

Authors:  Ignacio Oulego-Erroz; Rafael González-Cortes; Patricia García-Soler; Mónica Balaguer-Gargallo; Manuel Frías-Pérez; Juan Mayordomo-Colunga; Ana Llorente-de-la-Fuente; Paula Santos-Herraiz; Juan José Menéndez-Suso; María Sánchez-Porras; Daniel Palanca-Arias; Carmen Clavero-Rubio; Mª Soledad Holanda-Peña; Luis Renter-Valdovinos; Sira Fernández-De-Miguel; Antonio Rodríguez-Núñez
Journal:  Intensive Care Med       Date:  2017-12-01       Impact factor: 17.440

4.  Anesthesia of the Patient with Zhu-Tokita-Takenouchi-Kim (ZTTK) Syndrome: A Case Report.

Authors:  Jan Hudec; Martina Kosinova
Journal:  Children (Basel)       Date:  2022-06-11

Review 5.  Supraclavicular Approach to Ultrasound-Guided Brachiocephalic Vein Cannulation in Children and Neonates.

Authors:  Zied Merchaoui; Ulrik Lausten-Thomsen; Florence Pierre; Maher Ben Laiba; Nolwenn Le Saché; Pierre Tissieres
Journal:  Front Pediatr       Date:  2017-10-05       Impact factor: 3.418

6.  Safety and efficacy of the oblique-axis plane in ultrasound-guided internal jugular vein puncture: A meta-analysis.

Authors:  Shuai Miao; Xiuli Wang; Lan Zou; Ye Zhao; Guanglei Wang; Yuepeng Liu; Su Liu
Journal:  J Int Med Res       Date:  2018-04-05       Impact factor: 1.671

7.  Femoral Arteriovenous Fistula Associated With Leg Swelling 6 Months After Removal of a Hemodialysis Catheter: A Case Report.

Authors:  Lie Jin; Jian Wang; Chuifen Wu; Chuxiao Shao; Xueping Yu; Wenhui Lei
Journal:  Medicine (Baltimore)       Date:  2015-10       Impact factor: 1.817

  7 in total