Literature DB >> 26134808

Energy spectra considerations for synchrotron radiotherapy trials on the ID17 bio-medical beamline at the European Synchrotron Radiation Facility.

Jeffrey C Crosbie1, Pauline Fournier2, Stefan Bartzsch3, Mattia Donzelli4, Iwan Cornelius2, Andrew W Stevenson5, Herwig Requardt4, Elke Bräuer-Krisch4.   

Abstract

The aim of this study was to validate the kilovoltage X-ray energy spectrum on the ID17 beamline at the European Synchrotron Radiation Facility (ESRF). The purpose of such validation was to provide an accurate energy spectrum as the input to a computerized treatment planning system, which will be used in synchrotron microbeam radiotherapy trials at the ESRF. Calculated and measured energy spectra on ID17 have been reported previously but recent additions and safety modifications to the beamline for veterinary trials warranted a fresh investigation. The authors used an established methodology to compare X-ray attenuation measurements in copper sheets (referred to as half value layer measurements in the radiotherapy field) with the predictions of a theoretical model. A cylindrical ionization chamber in air was used to record the relative attenuation of the X-ray beam intensity by increasing thicknesses of high-purity copper sheets. The authors measured the half value layers in copper for two beamline configurations, which corresponded to differing spectral conditions. The authors obtained good agreement between the measured and predicted half value layers for the two beamline configurations. The measured first half value layer was 1.754 ± 0.035 mm Cu and 1.962 ± 0.039 mm Cu for the two spectral conditions, compared with theoretical predictions of 1.763 ± 0.039 mm Cu and 1.984 ± 0.044 mm Cu, respectively. The calculated mean energies for the two conditions were 105 keV and 110 keV and there was not a substantial difference in the calculated percentage depth dose curves in water between the different spectral conditions. The authors observed a difference between their calculated energy spectra and the spectra previously reported by other authors, particularly at energies greater than 100 keV. The validation of the beam spectrum by the copper half value layer measurements means the authors can provide an accurate spectrum as an input to a treatment planning system for the forthcoming veterinary trials of microbeam radiotherapy to spontaneous tumours in cats and dogs.

Entities:  

Keywords:  energy spectra; synchrotron radiotherapy; treatment planning

Mesh:

Year:  2015        PMID: 26134808     DOI: 10.1107/S1600577515008115

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  10 in total

1.  Development of Ultra-High Dose-Rate (FLASH) Particle Therapy.

Authors:  Michele M Kim; Arash Darafsheh; Jan Schuemann; Ivana Dokic; Olle Lundh; Tianyu Zhao; José Ramos-Méndez; Lei Dong; Kristoffer Petersson
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-06-22

2.  Megavolt bremsstrahlung measurements from linear induction accelerators demonstrate possible use as a FLASH radiotherapy source to reduce acute toxicity.

Authors:  Stephen E Sampayan; Kristin C Sampayan; George J Caporaso; Yu-Jiuan Chen; Steve Falabella; Steven A Hawkins; Jason Hearn; James A Watson; Jan-Mark Zentler
Journal:  Sci Rep       Date:  2021-08-24       Impact factor: 4.996

Review 3.  Microbeam radiation therapy - grid therapy and beyond: a clinical perspective.

Authors:  Elisabeth Schültke; Jacques Balosso; Thomas Breslin; Guido Cavaletti; Valentin Djonov; Francois Esteve; Michael Grotzer; Guido Hildebrandt; Alexander Valdman; Jean Laissue
Journal:  Br J Radiol       Date:  2017-07-27       Impact factor: 3.039

4.  Hybrid dose calculation: a dose calculation algorithm for microbeam radiation therapy.

Authors:  Mattia Donzelli; Elke Bräuer-Krisch; Uwe Oelfke; Jan J Wilkens; Stefan Bartzsch
Journal:  Phys Med Biol       Date:  2018-02-13       Impact factor: 3.609

5.  Computational modelling of the cerebral cortical microvasculature: effect of x-ray microbeams versus broad beam irradiation.

Authors:  A Merrem; S Bartzsch; J Laissue; U Oelfke
Journal:  Phys Med Biol       Date:  2017-03-23       Impact factor: 3.609

6.  Clinical microbeam radiation therapy with a compact source: specifications of the line-focus X-ray tube.

Authors:  Johanna Winter; Marek Galek; Christoph Matejcek; Jan J Wilkens; Kurt Aulenbacher; Stephanie E Combs; Stefan Bartzsch
Journal:  Phys Imaging Radiat Oncol       Date:  2020-06-11

7.  Microbeam Irradiation as a Simultaneously Integrated Boost in a Conventional Whole-Brain Radiotherapy Protocol.

Authors:  Felix Jaekel; Elke Bräuer-Krisch; Stefan Bartzsch; Jean Laissue; Hans Blattmann; Marten Scholz; Julia Soloviova; Guido Hildebrandt; Elisabeth Schültke
Journal:  Int J Mol Sci       Date:  2022-07-28       Impact factor: 6.208

8.  Ultra-high dose rate dosimetry: Challenges and opportunities for FLASH radiation therapy.

Authors:  Francesco Romano; Claude Bailat; Patrik Gonçalves Jorge; Michael Lloyd Franz Lerch; Arash Darafsheh
Journal:  Med Phys       Date:  2022-05-07       Impact factor: 4.506

9.  Survival of rats bearing advanced intracerebral F 98 tumors after glutathione depletion and microbeam radiation therapy: conclusions from a pilot project.

Authors:  E Schültke; E Bräuer-Krisch; H Blattmann; H Requardt; J A Laissue; G Hildebrandt
Journal:  Radiat Oncol       Date:  2018-05-10       Impact factor: 3.481

10.  The versatile X-ray beamline of the Munich Compact Light Source: design, instrumentation and applications.

Authors:  Benedikt Günther; Regine Gradl; Christoph Jud; Elena Eggl; Juanjuan Huang; Stephanie Kulpe; Klaus Achterhold; Bernhard Gleich; Martin Dierolf; Franz Pfeiffer
Journal:  J Synchrotron Radiat       Date:  2020-07-31       Impact factor: 2.616

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.