Literature DB >> 26134492

Intraoperative Measurement of the Distance from the Bottom of Osteotomy to the Mandibular Canal Using a Novel Ultrasonic Device.

Hadar Zigdon-Giladi1,2, Michael Saminsky3, Rina Elimelech3, Eli E Machtei3,4.   

Abstract

BACKGROUND: In our previous study, we found that a novel ultrasound (US) device may serve as a useful intraoperative tool to measure the distance from osteotomy to the inferior alveolar canal (IAC).
PURPOSE: To validate our previous results in a larger group of osteotomies in the posterior mandible.
METHODS: During dental implant placement surgery, osteotomies were created using a standardized 2-mm-diameter pilot drill. The distance from the bottom of the osteotome to the IAC was assessed using an ultrasonic device and compared with a standard panoramic radiograph used to measure the same residual distance. The total distance from the crestal bone to the IAC was measured on a preoperative computed tomography (CT) and compared with total US measurements by summing the drill depth with residual depth measurements.
RESULTS: Mean radiographic and US residual distances were 5.19 ± 1.95 mm, 5.01 ± 1.82 mm, p = 0.79 respectively. These measurements presented strong positive correlations (r = 0.61, p = .01). Mean total CT distance was 13.48 ± 2.66 mm; mean total US calculation was 13.69 ± 2.51 mm. No significant difference was found (p > .05).
CONCLUSIONS: The results support our previous pilot study and confirm that the tested US device identifies the IAC and measures the distance from the osteotomy to the roof of the mandibular canal.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  cone-beam computed tomography; implant; mandibular nerve; mandibular osteotomy

Mesh:

Year:  2015        PMID: 26134492     DOI: 10.1111/cid.12362

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  5 in total

1.  Updates on ultrasound research in implant dentistry: a systematic review of potential clinical indications.

Authors:  Vaishnavi Bhaskar; Hsun-Liang Chan; Mark MacEachern; Oliver D Kripfgans
Journal:  Dentomaxillofac Radiol       Date:  2018-06-06       Impact factor: 2.419

2.  Ultrasonographic evaluation of edentulous crestal bone topography: A proof-of-principle retrospective study.

Authors:  Khaled Sinjab; Oliver D Kripfgans; Alice Ou; Hsun-Liang Chan
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2021-07-18

3.  New US device versus imaging US to assess tumor-in-brain.

Authors:  Jacob Halevy-Politch; Menashe Zaaroor; Alon Sinai; Marius Constantinescu
Journal:  Chin Neurosurg J       Date:  2020-08-05

4.  Ultrasonography for diagnosis of peri-implant diseases and conditions: a detailed scanning protocol and case demonstration.

Authors:  Hsun-Liang Chan; Oliver D Kripfgans
Journal:  Dentomaxillofac Radiol       Date:  2020-02-06       Impact factor: 2.419

5.  Comparison of ultrasound imaging and cone-beam computed tomography for examination of the alveolar bone level: A systematic review.

Authors:  Kim-Cuong T Nguyen; Camila Pachêco-Pereira; Neelambar R Kaipatur; June Cheung; Paul W Major; Lawrence H Le
Journal:  PLoS One       Date:  2018-10-03       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.