Literature DB >> 26133634

Resting myocardial blood flow quantification using contrast-enhanced magnetic resonance imaging in the presence of stenosis: A computational fluid dynamics study.

Karsten Sommer1, Dominik Bernat2, Regine Schmidt2, Hanns-Christian Breit2, Laura M Schreiber3.   

Abstract

PURPOSE: The extent to which atherosclerotic plaques affect contrast agent (CA) transport in the coronary arteries and, hence, quantification of myocardial blood flow (MBF) using magnetic resonance imaging (MRI) is unclear. The purpose of this work was to evaluate the influence of plaque induced stenosis both on CA transport and on the accuracy of MBF quantification.
METHODS: Computational fluid dynamics simulations in a high-detailed realistic vascular model were employed to investigate CA bolus transport in the coronary arteries. The impact of atherosclerosis was analyzed by inserting various medium- to high-grade stenoses in the vascular model. The influence of stenosis morphology was examined by varying the stenosis shapes but keeping the area reduction constant. Errors due to CA bolus transport were analyzed using the tracer-kinetic model MMID4.
RESULTS: Dispersion of the CA bolus was found in all models and for all outlets, but with a varying magnitude. The impact of stenosis was complex: while high-grade stenoses amplified dispersion, mild stenoses reduced the effect. Morphology was found to have a marked influence on dispersion for a small number of outlets in the post-stenotic region. Despite this marked influence on the concentration-time curves, MBF errors were less affected by stenosis. In total, MBF was underestimated by -7.9% to -44.9%.
CONCLUSIONS: The presented results reveal that local hemodynamics in the coronary vasculature appears to have a direct impact on CA bolus dispersion. Inclusion of atherosclerotic plaques resulted in a complex alteration of this effect, with both degree of area reduction and stenosis morphology affecting the amount of dispersion. This strong influence of vascular transport effects impairs the accuracy of MRI-based MBF quantification techniques and, potentially, other bolus-based perfusion measurement techniques like computed tomography perfusion imaging.

Entities:  

Mesh:

Year:  2015        PMID: 26133634     DOI: 10.1118/1.4922708

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Numerical analysis of the pressure drop across highly-eccentric coronary stenoses: application to the calculation of the fractional flow reserve.

Authors:  R Agujetas; M R González-Fernández; J M Nogales-Asensio; J M Montanero
Journal:  Biomed Eng Online       Date:  2018-05-30       Impact factor: 2.819

Review 2.  Non-invasive Ischaemia Testing in Patients With Prior Coronary Artery Bypass Graft Surgery: Technical Challenges, Limitations, and Future Directions.

Authors:  Andreas Seraphim; Kristopher D Knott; Joao B Augusto; Katia Menacho; Sara Tyebally; Benjamin Dowsing; Sanjeev Bhattacharyya; Leon J Menezes; Daniel A Jones; Rakesh Uppal; James C Moon; Charlotte Manisty
Journal:  Front Cardiovasc Med       Date:  2021-12-23

3.  Clinical quantitative cardiac imaging for the assessment of myocardial ischaemia.

Authors:  Marc Dewey; Maria Siebes; Marc Kachelrieß; Klaus F Kofoed; Pál Maurovich-Horvat; Konstantin Nikolaou; Wenjia Bai; Andreas Kofler; Robert Manka; Sebastian Kozerke; Amedeo Chiribiri; Tobias Schaeffter; Florian Michallek; Frank Bengel; Stephan Nekolla; Paul Knaapen; Mark Lubberink; Roxy Senior; Meng-Xing Tang; Jan J Piek; Tim van de Hoef; Johannes Martens; Laura Schreiber
Journal:  Nat Rev Cardiol       Date:  2020-02-24       Impact factor: 32.419

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.