Literature DB >> 26130375

Bone ingrowth around porous-coated acetabular implant: a three-dimensional finite element study using mechanoregulatory algorithm.

Kaushik Mukherjee1, Sanjay Gupta2.   

Abstract

Fixation of uncemented implant is influenced by peri-prosthetic bone ingrowth, which is dependent on the mechanical environment of the implant-bone structure. The objective of the study is to gain an insight into the tissue differentiation around an acetabular component. A mapping framework has been developed to simulate appropriate mechanical environment in the three-dimensional microscale model, implement the mechanoregulatory tissue differentiation algorithm and subsequently assess spatial distribution of bone ingrowth around an acetabular component, quantitatively. The FE model of implanted pelvis subjected to eight static load cases during a normal walking cycle was first solved. Thereafter, a mapping algorithm has been employed to include the variations in implant-bone relative displacement and host bone material properties from the macroscale FE model of implanted pelvis to the microscale FE model of the beaded implant-bone interface. The evolutionary tissue differentiation was observed in each of the 13 microscale models corresponding to 13 acetabular regions. The total implant-bone relative displacements, averaged over each region of the acetabulum, were found to vary between 10 and 60 μm. Both the linear elastic and biphasic poroelastic models predicted similar mechanoregulatory peri-prosthetic tissue differentiation. Considerable variations in bone ingrowth (13-88%), interdigitation depth (0.2-0.82 mm) and average tissue Young's modulus (970-3430 MPa) were predicted around the acetabular cup. A progressive increase in the average Young's modulus, interdigitation depth and decrease in average radial strains of newly formed tissue layer were also observed. This scheme can be extended to investigate tissue differentiation for different surface texture designs on the implants.

Entities:  

Keywords:  Biphasic poroelastic model; Linear elastic model; Mechanoregulatory algorithm; Tissue differentiation; Uncemented acetabular implant

Mesh:

Substances:

Year:  2015        PMID: 26130375     DOI: 10.1007/s10237-015-0696-7

Source DB:  PubMed          Journal:  Biomech Model Mechanobiol        ISSN: 1617-7940


  8 in total

Review 1.  Biomechanical behaviours of the bone-implant interface: a review.

Authors:  Xing Gao; Manon Fraulob; Guillaume Haïat
Journal:  J R Soc Interface       Date:  2019-07-31       Impact factor: 4.118

2.  Mechanobiological simulations of peri-acetabular bone ingrowth: a comparative analysis of cell-phenotype specific and phenomenological algorithms.

Authors:  Kaushik Mukherjee; Sanjay Gupta
Journal:  Med Biol Eng Comput       Date:  2016-06-02       Impact factor: 2.602

3.  Acetabular custom-made implants for severe acetabular bone defect in revision total hip arthroplasty: a systematic review of the literature.

Authors:  Francesco Chiarlone; Andrea Zanirato; Luca Cavagnaro; Mattia Alessio-Mazzola; Lamberto Felli; Giorgio Burastero
Journal:  Arch Orthop Trauma Surg       Date:  2020-01-20       Impact factor: 3.067

Review 4.  Laser Sintering Approaches for Bone Tissue Engineering.

Authors:  Jeremy N DiNoro; Naomi C Paxton; Jacob Skewes; Zhilian Yue; Philip M Lewis; Robert G Thompson; Stephen Beirne; Maria A Woodruff; Gordon G Wallace
Journal:  Polymers (Basel)       Date:  2022-06-09       Impact factor: 4.967

5.  Healing Pattern Analysis for Dental Implants Using the Mechano-Regulatory Tissue Differentiation Model.

Authors:  Ming-Jun Li; Pei-Ching Kung; Yuan-Wei Chang; Nien-Ti Tsou
Journal:  Int J Mol Sci       Date:  2020-12-02       Impact factor: 5.923

6.  A novel revision system for complex pelvic defects utilizing 3D-printed custom prosthesis.

Authors:  Yongqiang Hao; Dinghao Luo; Junxiang Wu; Lei Wang; Kai Xie; Mengning Yan; Kerong Dai; Yongqiang Hao
Journal:  J Orthop Translat       Date:  2021-12-15       Impact factor: 5.191

7.  Engineer design process assisted by explainable deep learning network.

Authors:  Chia-Wei Hsu; An-Cheng Yang; Pei-Ching Kung; Nien-Ti Tsou; Nan-Yow Chen
Journal:  Sci Rep       Date:  2021-11-18       Impact factor: 4.379

8.  Biomechanical effect of metal augment and bone graft on cup stability for acetabular reconstruction of total hip arthroplasty in hip dysplasia: a finite element analysis.

Authors:  Yuzhu Wang; Mincong Wang; Chengguo Li; Yoshihiro Nakamura; Liwei Deng; Go Yamako; Etsuo Chosa; Chenglong Pan
Journal:  BMC Musculoskelet Disord       Date:  2022-03-23       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.