Literature DB >> 26130240

Correlation between three-dimentional surface topography and color stability of different nanofilled composites.

Elif Öztürk1, Gizem Güder2.   

Abstract

AIM: The aim of this study was to evaluate the 3-dimensional (3D) surface topography and color stability of four different resin composites after immersion in different soft-beverages.
MATERIALS AND METHODS: One hundred sixty disk-shaped specimens (diameter: 10 mm, and thickness: 2 mm) were made from four different resin composites (i.e., Filtek Z550, Tetric N-Ceram, Clearfil Majesty Esthetic, and Cavex Quadrant Universal LC). Each specimen was cured under mylar strips for 20 sec for both top and bottom surfaces. All of the specimens were stored in distilled water for 24 h at 37°C. Surface measurements were carried out using a noncontact 3D-optical-profilometer in terms of surface topography (Ra values). Color measurements of each specimen were performed with Vita Easy Shade system. All the measurements were performed at baseline and after 30 days of immersion in the selected soft-beverages (Redbull, Coca-Cola and Dimes-Lemonade). Control groups were stored in distilled water during the study. Ra values and color changes (ΔE values) of the groups were recorded. The data were statistically analyzed using a one way ANOVA and Tukey's post-hoc tests (SPSS 18.0).
RESULTS: The tested soft-beverages in the present study caused color changes at a 30-day evaluation period for the tested resin composites (p < 0.05). However, 3D surface topography of resin composites was not influenced by the tested soft-beverages (p > 0.05). There was no significant interaction between the composite and beverage type on the Ra values of the resin composites (p > 0.05).
CONCLUSIONS: No correlation was found between color stability and 3D surface topography of the resin composites. Color stability of resin composites may be affected by soft beverages. © Wiley Periodicals, Inc.

Entities:  

Keywords:  3D-Surface topography; color stability; optical profilometry; resin composites

Mesh:

Substances:

Year:  2015        PMID: 26130240     DOI: 10.1002/sca.21233

Source DB:  PubMed          Journal:  Scanning        ISSN: 0161-0457            Impact factor:   1.932


  2 in total

1.  Effect of 2 Bleaching Agents with a Content of High Concentrated Hydrogen Peroxide on Stained 2 CAD/CAM Blocks and a Nanohybrid Composite Resin: An AFM Evaluation.

Authors:  İzgen Karakaya; Esra Cengiz
Journal:  Biomed Res Int       Date:  2017-07-18       Impact factor: 3.411

2.  Color stability and surface roughness of ormocer- versus methacrylate-based single shade composite in anterior restoration.

Authors:  Maha M Ebaya; Ashraf I Ali; Huda Abed El-Haliem; Salah Hasab Mahmoud
Journal:  BMC Oral Health       Date:  2022-09-27       Impact factor: 3.747

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.