Literature DB >> 26124040

Novel universal system for 3-dimensional orthodontic force-moment measurements and its clinical use.

Margherita Mencattelli1, Elisa Donati2, Massimo Cultrone3, Cesare Stefanini4.   

Abstract

INTRODUCTION: Orthodontic treatment is an important part of dental health care in Europe: the percentages of the population undergoing therapy vary from 10% to 55%. Therefore, quantifying effective orthodontic loads is a challenging topic with regard to the predictability of tooth movements and the reduction of traumatic side effects.
METHODS: A customized measuring platform was developed and used for detecting orthodontic forces in a range between 0.1 and 2 N. The system consists of 6 load cells, each equipped with 6 strain gauges. The tests were conducted on a 3-dimensional printed malocclused mouth model and on a plaster cast. Four types of superelastic ligation and 2 types of invisible aligners were tested to analyze, respectively, a malocclusion with a high maxillary canine, and the effects on the axial rotation of a maxillary central incisor with and without a divot in the invisible aligners.
RESULTS: Optimal treatment forces are exerted by low-friction wires, especially if they are partially engaged. Moreover, by reducing the treatment force, there is less necessity of anchoring to surrounding teeth, thus decreasing the side effects. The efficacy of using invisible aligners with a divot was validated.
CONCLUSIONS: This platform allowed measurement, at the radicular level, of the resultant forces of orthodontic treatments performed with different orthodontic appliances. In addition to customizing and calibrating the therapy for each patient, this platform could be used to develop new specific instruments able to exert lower treatment forces, thus preventing irreversible damages.
Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26124040     DOI: 10.1016/j.ajodo.2015.01.028

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  4 in total

1.  Clear aligners with differentiated thickness and without attachments - A case report.

Authors:  Alessandra Putrino; Maria-Rosaria Abed; Carlo Lilli
Journal:  J Clin Exp Dent       Date:  2022-06-01

2.  Evaluation of the load system produced by a single intrusion bend in a maxillary lateral incisor bracket with different alloys.

Authors:  Ricardo Lima Shintcovsk; Roberto Soares da Silva Júnior; Larry White; Lidia Parsekian Martins; Renato Parsekian Martins
Journal:  Angle Orthod       Date:  2018-05-15       Impact factor: 2.079

Review 3.  Clear Aligners: Between Evolution and Efficiency-A Scoping Review.

Authors:  Alessandra Putrino; Ersilia Barbato; Gabriella Galluccio
Journal:  Int J Environ Res Public Health       Date:  2021-03-11       Impact factor: 3.390

4.  Biomechanical investigation of orthodontic treatment planning based on orthodontic force measurement and finite element method before implementation: A case study.

Authors:  Jianlei Wu; Yunfeng Liu; Jianxing Zhang; Wei Peng; Xianfeng Jiang
Journal:  Technol Health Care       Date:  2018       Impact factor: 1.285

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.