Literature DB >> 26121601

Numerical Methodology to Evaluate the Effects of Bone Density and Cement Augmentation on Fixation Stiffness of Bone-Anchoring Devices.

Yan Chevalier.   

Abstract

Bone quality is one of the reported factors influencing the success of bone anchors in arthroscopic repairs of torn rotator cuffs at the shoulder. This work was aimed at developing refined numerical methods to investigate how bone quality can influence the fixation stiffness of bone anchors. To do that bone biopsies were scanned at 26-μm resolution with a high-resolution microcomputer tomography (micro-CT) scanner and their images were processed for virtual implantation of a typical design of bone anchor. These were converted to microfinite element (μFE) and homogenized classical FE models, and analyses were performed to simulate pulling on the bone anchor with and without cement augmentation. Quantification of structural stiffness for each implanted specimen was then computed, as well as stress distributions within the bone structures, and related to the bone volume fraction of the specimens. Results show that the classical method is excellently correlated to structural predictions of the more refined μFE method, despite the qualitative differences in local stresses in the bone surrounding the implant. Predictions from additional loading cases suggest that structural fixation stiffness in various directions is related to apparent bone density of the surrounding bone. Augmentation of anchoring with bone cement stiffens the fixation and alters these relations. This work showed the usability of homogenized FE (hFE) in the evaluation of bone anchor fixation and will be used to develop new methodologies for virtual investigations leading to optimized repairs of rotator cuff and glenoid Bankart lesions.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26121601     DOI: 10.1115/1.4030943

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  3 in total

1.  Analysis of the three-dimensional anatomical variance of the distal radius using 3D shape models.

Authors:  Sebastian F Baumbach; Jakob Binder; Alexander Synek; Fabian G Mück; Yan Chevalier; Ekkehard Euler; Georg Langs; Lukas Fischer
Journal:  BMC Med Imaging       Date:  2017-03-09       Impact factor: 1.930

2.  The effect of cement augmentation on pedicle screw fixation under various load cases : results from a combined experimental, micro-CT, and micro-finite element analysis.

Authors:  Yan Chevalier; Maiko Matsuura; Sven Krüger; Hannes Traxler; Christoph Fleege; Michael Rauschmann; Christoph Schilling
Journal:  Bone Joint Res       Date:  2021-12       Impact factor: 5.853

3.  Metaphyseal anchoring short stem hip arthroplasty provides a more physiological load transfer: a comparative finite element analysis study.

Authors:  Shuang G Yan; Yan Chevalier; Fanxiao Liu; Xingyi Hua; Anna Schreiner; Volkmar Jansson; Florian Schmidutz
Journal:  J Orthop Surg Res       Date:  2020-10-29       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.