Literature DB >> 26120377

IMAGE REGISTRATION ERROR ANALYSIS WITH APPLICATIONS IN SINGLE MOLECULE MICROSCOPY.

E A K Cohen1, R J Ober1.   

Abstract

This paper is concerned with assessing localization errors emanating from the image registration of two monochromatic fluorescence microscopy images. Assuming an affine transform exists between images, registration in this setting typically involves using control points to solve a multivariate linear regression problem; however with measurement errors existing in both sets of variables the use of linear least squares is inappropriate. It is shown that image registration is an errors-in-variable problem and as such the correct method is to use generalized least squares. Traditionally this requires the measurement errors to be independent and identically distributed (iid); an assumption that is rarely satisfied in practical situations. An extension of the multivariate generalized least squares estimator that allows non-iid noise is applied. The distributional properties of the estimators are used to derive localization errors emanating from the image registration process in terms of photon counts and experimental parameters.

Entities:  

Keywords:  Image registration; Microscopy; Total least squares methods

Year:  2012        PMID: 26120377      PMCID: PMC4479212          DOI: 10.1109/ISBI.2012.6235725

Source DB:  PubMed          Journal:  Proc IEEE Int Symp Biomed Imaging        ISSN: 1945-7928


  6 in total

1.  Tracking single proteins within cells.

Authors:  M Goulian; S M Simon
Journal:  Biophys J       Date:  2000-10       Impact factor: 4.033

2.  Co-localization analysis of complex formation among membrane proteins by computerized fluorescence microscopy: application to immunofluorescence co-patching studies.

Authors:  E Lachmanovich; D E Shvartsman; Y Malka; C Botvin; Y I Henis; A M Weiss
Journal:  J Microsc       Date:  2003-11       Impact factor: 1.758

3.  Localization accuracy in single-molecule microscopy.

Authors:  Raimund J Ober; Sripad Ram; E Sally Ward
Journal:  Biophys J       Date:  2004-02       Impact factor: 4.033

4.  Beyond Rayleigh's criterion: a resolution measure with application to single-molecule microscopy.

Authors:  Sripad Ram; E Sally Ward; Raimund J Ober
Journal:  Proc Natl Acad Sci U S A       Date:  2006-03-01       Impact factor: 11.205

5.  Imaging individual green fluorescent proteins.

Authors:  D W Pierce; N Hom-Booher; R D Vale
Journal:  Nature       Date:  1997-07-24       Impact factor: 49.962

6.  Bacteria detection with thin wetting 
film lensless imaging.

Authors:  C P Allier; G Hiernard; V Poher; J M Dinten
Journal:  Biomed Opt Express       Date:  2010-08-31       Impact factor: 3.732

  6 in total
  2 in total

1.  Analysis of Point Based Image Registration Errors With Applications in Single Molecule Microscopy.

Authors:  E A K Cohen; R J Ober
Journal:  IEEE Trans Signal Process       Date:  2013-12-15       Impact factor: 4.931

2.  Measurement Errors in Fluorescence Microscopy Image Registration.

Authors:  E A K Cohen; R J Ober
Journal:  Conf Rec Asilomar Conf Signals Syst Comput       Date:  2012-11-01
  2 in total