Literature DB >> 26110369

Clinical practice of ambulatory versus home blood pressure monitoring in hypertensive patients.

Jorge A Paolasso1, Florencia Crespo, Viviana Arias, Eduardo A Moreyra, Ariel Volmaro, Marcelo Orías, Eduardo Moreyra.   

Abstract

OBJECTIVES: This study aimed to analyze whether blood pressure (BP) measurement is concordant between ambulatory blood pressure monitoring (ABPM) and home blood pressure monitoring (HBPM), and determine whether the decision on treatment changes is similar on the basis of information provided by both methods.
METHODS: Treated hypertensive patients were studied with ABPM and HBPM to evaluate therapeutic efficacy and/or diagnose resistant hypertension (HTN). Modification of pharmacological treatment was decided on the basis of pre-established criteria; therefore, the number of therapeutic changes between both techniques was compared.
RESULTS: A total of 200 patients were included. The average daytime ABPM systolic blood pressure (SBP) was 136±16 compared with 136±15 (P=1) with HBPM; the average diurnal diastolic blood pressure (DBP) was 83±12 and 81±9, respectively (P=0.06). The concordance between both methods was very good for SBP [r=0.85; Bland-Altman 0.2 (95% confidence interval 0.9-1.4 mmHg)], and good for the DBP [r=0.77; Bland-Altman 1.8 (95% confidence interval 0.8-2.8 mmHg)]. Both methods were in agreement that HTN was controlled in 68 patients and that it was not controlled in 90 patients, that is, they were concordant in 158 patients (79%, κ=0.6). More patients required changes with ABPM than HBPM (149 vs. 99 patients, P<0.0001)
CONCLUSION: There were no significant differences in the measurement of diurnal SBP and DBP between both methods. The concordance to determine proper control of HTN was 79%. There was a significant difference in the decision to modify the treatment in favor of the ABPM.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26110369     DOI: 10.1097/MBP.0000000000000138

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  2 in total

1.  Blood Pressure Measurement Modalities: A Primer for Busy Practitioners.

Authors:  L Allen Kindman; J Rick Turner; John Lee
Journal:  J Clin Hypertens (Greenwich)       Date:  2015-11-12       Impact factor: 3.738

2.  Arterial Stiffness in Treated Hypertensive Patients With White-Coat Hypertension.

Authors:  Jessica Barochiner; Lucas S Aparicio; José Alfie; Margarita S Morales; Paula E Cuffaro; Marcelo A Rada; Marcos J Marin; Carlos R Galarza; Gabriel D Waisman
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-09-28       Impact factor: 3.738

  2 in total