Vasileios Patris1, Orestis Argiriou2, Niki Lama1, Haris Georgiou3, Constantine Halkias4, Christos Charitos3.
Abstract
Cutaneous complications caused by a pacemaker or defibrillator are widely documented, but the development of a bronchocutaneous fistula has never been described before. We report the case of a 79-year-old man who was admitted to our hospital because of a seemingly superficial cutaneous infection, externalized defibrillator leads, and hemoptysis. Bronchoscopical investigation proved the existence of the fistula, which connected the epicardium, the left main bronchus, and the aforementioned site of skin infection. The patient refused an operation for the complete removal of the epicardial defibrillator and was treated conservatively. This case demonstrated that the long-term presence of foreign bodies in the epicardium may cause serious complications.Entities:
Keywords: Defibrillator; Fistula; Hemoptysis; Pacemaker; artificial; implantable
Year: 2015 PMID: 26110011 PMCID: PMC4477085
Source DB: PubMed Journal: J Tehran Heart Cent ISSN: 1735-5370
Figure 1Lateral chest radiograph, showing the externalization of the leads (arrow)
Figure 2Computed tomography, showing the epicardial patch electrode in contact with the LMB (left main bronchus)