Cheng-Dong Piao1, Kun Yang2, Peng Li3, Min Luo4. 1. Department of Orthopedics, Second Hospital, Jilin University, Changchun, Jilin Province, China. 2. Basic Department, Air Force Aviation University of Chinese PLA, Changchun, Jilin Province, China. 3. Department of Engineering Mechanics, Nanling Campus, Jilin University, Changchun, Jilin Province, China. 4. Department of Pain, China-Japan Union Hospital, Jilin University, Changchun, Jilin Province, China.
Abstract
In the repair of peripheral nerve injury using autologous or synthetic nerve grafting, the magnitude of tensile forces at the anastomosis affects its response to physiological stress and the ultimate success of the treatment. One-dimensional stretching is commonly used to measure changes in tensile stress and strain; however, the accuracy of this simple method is limited. Therefore, in the present study, we established three-dimensional finite element models of sciatic nerve defects repaired by autologous nerve grafts. Using PRO E 5.0 finite element simulation software, we calculated the maximum stress and displacement of an anastomosis under a 5 N load in 10-, 20-, 30-, 40-mm long autologous nerve grafts. We found that maximum displacement increased with graft length, consistent with specimen force. These findings indicate that three-dimensional finite element simulation is a feasible method for analyzing stress and displacement at the anastomosis after autologous nerve grafting.
In the repair of peripheral nerve injury using autologous or synthetic nerve grafting, the magnitude of tensile forces at the anastomosis affects its response to physiological stress and the ultimate success of the treatment. One-dimensional stretching is commonly used to measure changes in tensile stress and strain; however, the accuracy of this simple method is limited. Therefore, in the present study, we established three-dimensional finite element models of sciatic nerve defects repaired by autologous nerve grafts. Using PRO E 5.0 finite element simulation software, we calculated the maximum stress and displacement of an anastomosis under a 5 N load in 10-, 20-, 30-, 40-mm long autologous nerve grafts. We found that maximum displacement increased with graft length, consistent with specimen force. These findings indicate that three-dimensional finite element simulation is a feasible method for analyzing stress and displacement at the anastomosis after autologous nerve grafting.
A number of studies have explored methods by which to assess peripheral nerve injury repair and associated biomechanical properties (Taylor et al., 2008; Cheng et al., 2009; Karabekmez et al., 2009; Alrashdan et al., 2010; di Summa et al., 2010; Dong et al., 2010; Ishiguro et al., 2010; Kadam et al., 2010; Szaro and Strong, 2010; Vinik, 2010; Bielle et al., 2011; Chen et al., 2011; Dadon-Nachum et al., 2011; Korte et al., 2011; Ngeow et al., 2011; Wolford and Rodrigues, 2011; Unni et al., 2012). Wang et al. (2009) confirmed that catheters synthetized from polycaprolactone and dimethyl fumarate were strong and showed good histocompatibility, and successfully promoted differentiation and regeneration of Schwann cells in rats with 10-mm sciatic nerve defects; good growth was observed by 6 weeks after grafting. Regeneration of the sciatic nerve was demonstrated 1 month after insertion of an artificial catheter made from nanosilver and type I collagen to repair a 10-mm sciatic nerve defect; retrograde tracing showed regenerating neurons in the dorsal root ganglion, and good electrophysiological function was observed (Ding et al. 2010). In a 10-mm sciatic nerve injury in fresh human tissue, Peng et al. (2012) showed that maximum tensile load, displacement, stress and strain were lower after repair using a multilayer curled amniotic tube than after autologous nerve anastomosis. Ngeow et al. (2011) confirmed that compound action potential was notably improved at 6 weeks, and recovery of gait function was good at 12 weeks, in animals with sciatic nerve injury after epineurial suturing.In the repair of peripheral nerve injury using autologous or synthetic nerve grafts, the magnitude of tension at the anastomosis is a crucial factor influencing the response of the graft to physiological stress and the success of the treatment. In previous studies, tension at the anastomosis under physiological load has commonly been measured using one-dimensional stretching (Wang et al., 2009; Peng et al., 2012). However, such techniques measure the tension across the whole specimen, rather than specifically at the anastomosis. Computer simulation can be used to create a three-dimensional (3D) model using the finite element method. This can be used to calculate the tension and deformation at the edge of a simulated anastomosis under physiological load, and to directly and precisely identify the mechanical properties at its edge. Thus, the technique has clinical value in sciatic nerve injury grafts.We established 3D finite element models of sciatic nerve defects repaired by different lengths of autologous nerve grafts, and used them to calculate the stress and displacement at the anastomosis. Here, we provide a simulated modeling and calculation method for exploring grafting and repair of sciatic nerve injury in the clinic.
Materials and Methods
Establishment of 3D finite element models of sciatic nerve injury repaired by autologous nerve grafting
Small deformations of the sciatic nerve are elastic (Peng et al., 2012). More precisely, the sciatic nerve is a viscoelastic material, but at present it is difficult to model as such. Therefore, to simplify the calculation process, we assume here that the sciatic nerve is a thin-walled incompressible isotropic elastic tube.We used the average dimensions of the gluteus maximus segment of the sciatic nerve in the Chinese population (length, 170 mm; outer diameter, 11 mm; inner diameter, 9 mm; Yan and Huang, 1998) as input parameters for PRO E 5.0 finite element analysis software (Parametric Technology Corporation, Needham, MA, USA) and produced 3D finite element models of sciatic nerve injury repaired by 10, 20, 30, and 40-mm autologous nerve grafts ().
Figure 1
Three-dimensional models of sciatic nerve injury repaired by autologous nerve grafting.
(A–D) Models of 10- (A), 20- (B), 30- (C), and 40-mm (D) long autologous nerve grafts. Yellow arrows represent tension; yellow line and point represent node; black represents tetrahedral element made by node connection; N represents load.
Three-dimensional models of sciatic nerve injury repaired by autologous nerve grafting.(A–D) Models of 10- (A), 20- (B), 30- (C), and 40-mm (D) long autologous nerve grafts. Yellow arrows represent tension; yellow line and point represent node; black represents tetrahedral element made by node connection; N represents load.Grid scheduling analysis and optimization were conducted in the models, which were meshed using PRO E 5.0. There were 4,901 tetrahedral elements in the 10-mm long graft models, 5,614 in the 20-mm long models, 5,492 in the 30-mm long models, and 6,045 in the 40-mm long models ().
Figure 2
Grid graphs of three-dimensional finite element models of sciatic nerve injury repaired by autologous nerve grafting.
(A–D) Grid graphs of models of 10- (A), 20- (B), 30- (C) and 40-mm (D) long autologous nerve grafts. (E) Tetrahedral elements and grid amplification. Displacements of the base was restricted. Yellow arrows represent tension; yellow point represents node; black lines represent node connection; N represents load.
Grid graphs of three-dimensional finite element models of sciatic nerve injury repaired by autologous nerve grafting.(A–D) Grid graphs of models of 10- (A), 20- (B), 30- (C) and 40-mm (D) long autologous nerve grafts. (E) Tetrahedral elements and grid amplification. Displacements of the base was restricted. Yellow arrows represent tension; yellow point represents node; black lines represent node connection; N represents load.A 5 N load was applied to the models, and PRO E 5.0 was used to calculate the stress and displacement at each element and node.
Boundary condition
A fixed constraint was used in each anastomosis at the distal end of the sciatic nerve injury models (). Only the sciatic nerve was included in the finite element calculation. The elastic modulus of the sciatic nerve was E = 40.96 ± 2.59 MP (Liu et al., 2012). The stress at each node was calculated according to Hooke’s law, σ = Eε (where σ = stress, E = elastic modulus, and ε = strain) (Liu, 1979).
Measurement points
Epineurial suturing was simulated in the models. Four measurement points were set at equal distances along the circumference at the upper and lower edges of the anastomosis, at each end of the model, i.e., 16 measurement points per model ().
Figure 3
Positions of the measurement points in the three- dimensional finite element simulation model of sciatic nerve injury repaired by autologous nerve grafting.
Four equally-spaced measuring points were set along the circumference at the upper and lower edges of the anastomosis at either end of the model, i.e., 16 measurement points per model.
Positions of the measurement points in the three- dimensional finite element simulation model of sciatic nerve injury repaired by autologous nerve grafting.Four equally-spaced measuring points were set along the circumference at the upper and lower edges of the anastomosis at either end of the model, i.e., 16 measurement points per model.
Statistical analysis
Data are expressed as the mean ± SD, and were analyzed using SPSS 16.0 software (SPSS, Chicago, IL, USA). One-way analysis of variance and Scheffe’s method were used to determine the significance of intergroup differences, and P < 0.05 was considered statistically significant.
Results
Under a 5 N load, the maximum displacement was found at measurement point 3 in the upper segment of the graft (designated Up3; ) in all four models. The largest maximum displacement was observed in the 40-mm long model, followed by 30- and 20-mm long models, and the smallest in the 10-mm long model (P < 0.05). That is, the longer the graft, the larger the displacement under the same load, consistent with mechanical laws. These data indicate that the simplification used in our 3D finite element model resulted in a reasonable simulation of sciatic nerve injury ().
Table 1
Maximum stress (MPa) and maximum displacement (mm) in the three-dimensional finite element simulation model of sciatic nerve injury repaired by autologous nerve grafts of various lengths
Maximum stress (MPa) and maximum displacement (mm) in the three-dimensional finite element simulation model of sciatic nerve injury repaired by autologous nerve grafts of various lengths
Discussion
The key to 3D finite element modeling is simplifying complex mechanical systems. Here, the sciatic nerve is considered to be a thin-walled elastic cylinder. The simplification of 3D finite element models used in the present simulation of sciatic nerve injury resulted in a reasonable representation of the mechanics of this complex system, and advanced PRO E 5.0 software was used to calculate the stress and displacement of each element and node under a 5 N load and uniaxial tension, providing reliable experimental results.The magnitude of tensile forces at the anastomosis under physiological stress is an important factor influencing the outcome of peripheral nerve injury repair after suturing (Yan and Huang, 1998). Our results demonstrated that under a 5 N load, the maximum displacement appeared at measurement point Up3 in all four autologous nerve grafts, showing good consistency across the models. Up3 lies at the right-hand upper edge of the proximal end of the anastomosis, and very near to the loading point, so its displacement is large. Under the same load, the maximum stress and displacement correlate with the length of the graft. Our data are in accordance with the specimen force law and comparable with results from previous studies, indicating that the present study design and mechanical simplification are reasonable representations of the system modeled.Previous studies have demonstrated that the tension and elongation of the anastomosis after injury to peripheral nerves such as the sciatic nerve are commonly measured by simple electrical measurement of stretch and strain at the site of the anastomosis (Yan and Huang, 1998; Ngeow et al., 2011). For example, Liu et al. (2012) used electrical measurement to determine the tensile forces at various points on a sciatic nerve anastomosis after perineurial or epineurial suturing, but used only a 10-mm long autologous nerve graft and one-dimensional tension. The present study is more representative of clinical practice, because we used 3D finite element models of sciatic nerve injury repaired by autologous nerve grafts of different lengths to calculate the stress and displacement at the anastomosis.In conclusion, our results demonstrate the feasibility of using a 3D finite element simulation model of sciatic nerve injury to predict anastomosis stress and displacement after autologous nerve grafting.