Literature DB >> 26109611

Bioabsorbable Versus Titanium Screws in Anterior Cruciate Ligament Reconstruction Using Hamstring Autograft: A Prospective, Blinded, Randomized Controlled Trial With 5-Year Follow-up.

Yuval Arama1, Lucy J Salmon1, Kesavan Sri-Ram1, James Linklater2, Justin P Roe3, Leo A Pinczewski4.   

Abstract

BACKGROUND: Longer-term results of bioabsorbable screws for anterior cruciate ligament reconstruction (ACLR) have been reported, but results are specific to the exact screw material and design. Titanium and poly-L-lactic acid with hydroxyapatite (PLLA-HA) screw outcomes have been compared only to 2 years. PURPOSE/HYPOTHESIS: The purpose of this study was to compare the clinical and radiologic outcomes of the PLLA-HA screw versus titanium screw for hamstring tendon ACLR over a 5-year follow-up period. The hypothesis was that there are no differences in clinical scores or tunnel widening between the PLLA-HA and the titanium screws and that the PLLA-HA screw as seen on magnetic resonance imaging (MRI) should show high-grade resorption and ossification response over 5 years. STUDY
DESIGN: Randomized controlled trial; Level of evidence, 1.
METHODS: A total of 40 patients undergoing ACLR were randomized to receive either a PLLA-HA screw (PLLA-HA group) or a titanium screw (titanium group) for ACL fixation. Blinded evaluation was performed at 2 and 5 years with the International Knee Documentation Committee and Lysholm knee score, KT-1000 arthrometer, single-legged hop test, and MRI to evaluate tunnel and screw volumes, periscrew ossification, graft integration, and cyst formation.
RESULTS: There was no difference in any clinical outcome measure at 2- or 5-year follow-up between the 2 groups. At 2 years, the femoral tunnel in the PLLA-HA group was smaller than that in the titanium group (P = .02); at 5 years, there was no difference. At 2 years, the femoral PLLA-HA screw was a mean 76% of its original volume, and by 5 years, it was 36%. At 2 years, the tibial PLLA-HA screw mean volume was 68% of its original volume, and by 5 years, it was 46%. At 5 years in the PLLA-HA group, 88% of femoral tunnels and 56% of tibial tunnels demonstrated a significant ossification response. There was no increase in cyst formation in the PLLA-HA group and no screw breakages.
CONCLUSION: There were equivalent clinical results between the PLLA-HA and titanium groups at 2- and 5-year follow-ups. The PLLA-HA screw was not associated with increased tunnel widening or cyst formation when compared with the titanium screw. The PLLA-HA screw demonstrated progressive screw resorption and gradual but incomplete ossification over 5 years.
© 2015 The Author(s).

Entities:  

Keywords:  ACL; bioabsorbable; clinical; fixation

Mesh:

Substances:

Year:  2015        PMID: 26109611     DOI: 10.1177/0363546515588926

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  9 in total

1.  Femoral-tibial fixation affects risk of revision and reoperation after anterior cruciate ligament reconstruction using hamstring autograft.

Authors:  Lindsey M Spragg; Heather A Prentice; Andrew Morris; Tadashi T Funahashi; Gregory B Maletis; Rick P Csintalan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-03-01       Impact factor: 4.342

Review 2.  Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction.

Authors:  Pedro Debieux; Carlos E S Franciozi; Mário Lenza; Marcel Jun Tamaoki; Robert A Magnussen; Flávio Faloppa; João Carlos Belloti
Journal:  Cochrane Database Syst Rev       Date:  2016-07-24

3.  Femoral Aperture Fixation Improves Anterior Cruciate Ligament Graft Function When Added to Cortical Suspensory Fixation: An In Vivo Computer Navigation Study.

Authors:  Mark D Porter; Bruce Shadbolt
Journal:  Orthop J Sports Med       Date:  2016-09-07

4.  Femoral and Tibial Tunnel Diameter and Bioabsorbable Screw Findings After Double-Bundle ACL Reconstruction in 5-Year Clinical and MRI Follow-up.

Authors:  Tommi Kiekara; Antti Paakkala; Piia Suomalainen; Heini Huhtala; Timo Järvelä
Journal:  Orthop J Sports Med       Date:  2017-02-02

5.  Three-Dimensional Printed Porous Titanium Screw with Bioactive Surface Modification for Bone-Tendon Healing: A Rabbit Animal Model.

Authors:  Yu-Min Huang; Chih-Chieh Huang; Pei-I Tsai; Kuo-Yi Yang; Shin-I Huang; Hsin-Hsin Shen; Hong-Jen Lai; Shu-Wei Huang; San-Yuan Chen; Feng-Huei Lin; Chih-Yu Chen
Journal:  Int J Mol Sci       Date:  2020-05-21       Impact factor: 5.923

6.  Does thread shape affect the fixation strength of the bioabsorbable interference screws for anterior cruciate ligament reconstructions? A biomechanical study.

Authors:  Gerardo L Garcés; Oscar Martel; Alejandro Yánez; Alberto Cuadrado
Journal:  BMC Musculoskelet Disord       Date:  2019-02-08       Impact factor: 2.362

7.  Biocomposite Interference Screws in Anterior Cruciate Ligament Reconstruction: Osteoconductivity and Degradation.

Authors:  F Alan Barber; W D Dockery
Journal:  Arthrosc Sports Med Rehabil       Date:  2020-01-30

8.  Complications of Bioabsorbable Tibial Interference Screws After Anterior Cruciate Ligament Reconstruction in Pediatric and Adolescent Athletes.

Authors:  Dennis E Kramer; Leslie A Kalish; Mininder S Kocher; Yi-Meng Yen; Lyle J Micheli; Benton E Heyworth
Journal:  Orthop J Sports Med       Date:  2020-02-26

Review 9.  A comprehensive scoping review of tibial cysts after anterior cruciate ligament reconstruction.

Authors:  Nuno Camelo Barbosa; João Pedro Campos; Vânia Capelão; Vikram Kandhari; Thais Dutra Vieira; Bertrand Sonnery-Cottet
Journal:  J Exp Orthop       Date:  2021-06-21
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.