Does postoperative blood pressure influence development of aortic regurgitation following continuous-flow left ventricular assist device implantation?†.

Nikhil Prakash Patil1, Prashant Nanasaheb Mohite2, Anton Sabashnikov2, Dhruva Dhar3, Alexander Weymann2, Mohamed Zeriouh2, Achim Koch2, Diana Garcia-Saez2, Bartlomiej Zych2, Rachel Hards2, Michael Hedger2, Fabio De Robertis2, Ajay Moza2, Toufan Bahrami2, Mohamed Amrani2, Shelley Rahman-Haley4, Aron Frederik Popov2, Nicholas Banner4, André Rudiger Simon2.   

Abstract

OBJECTIVES: The true impact of postoperative blood pressure (BP) control on development of aortic regurgitation (AR) following continuous-flow left ventricular assist device (CF-LVAD) implantation remains uncertain. This study examines the influence of BP in patients with de novo AR following CF-LVAD implantation.
METHODS: All patients with no or <mild AR who underwent CF-LVAD implantation from July 2006 to July 2012 at our institute and with subsequent device-support of ≥3months (n = 90) were studied. Serial echocardiograms and BP readings were obtained preoperatively, postoperatively at 1, 3 and 6 months, and then at a minimum of 4-monthly intervals. BP readings were compared between patients who developed mild AR (AR group) versus those who did not (non-AR group). Logistic regression analysis was used to define independent predictors of ≥mild AR following CF-LVAD implantation.
RESULTS: Median duration of CF-LVAD support was 575 days (range: 98-2433 days). Forty-eight patients (53.3%) developed mild AR over a median duration of 126 days. BP readings (median values, mmHg) between AR and non-AR groups showed statistically significant differences: at 3 months-systolic 99.5 vs 92.5 (P = 0.038), diastolic 81.5 vs 66 (P < 0.001), mean 86.5 vs 74 (P < 0.001) and at 6 months-diastolic 73 vs 62 (P = 0.044), mean 83 vs 74.5 (P = 0.049), respectively. Systolic BP at 3 months (P = 0.047, 95% CI 0.453-0.994, OR 0.671), aortic valve (AoV) closure (P = 0.01, 95% CI 0.002-0.429, OR 0.029) and duration of support (P = 0.04, 95% CI 1.000-1.009, OR 1.004) were found to be independent predictors of AR following CF-LVAD implantation.
CONCLUSIONS: BP readings at 3 months and 6 months showed a statistically significant association with ≥mild AR following CF-LVAD implantation, with systolic blood pressure at 3 months, aortic valve closure and longer support duration being independent predictors. Clinical implications of these data may warrant consideration of aggressive early control of BP to protect against the development/progress of AR following CF-LVAD implantation.
© The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic regurgitation; Blood pressure; Bridge to transplant; Hypertension; Left ventricular assist device

Mesh:

Year:  2015        PMID: 26108216     DOI: 10.1093/ejcts/ezv221

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  4 in total

1.  HeartMate 3-a "Step" in the right direction.

Authors:  Juglans Alvarez; Vivek Rao
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

Review 2.  Blood pressure management in mechanical circulatory support.

Authors:  Mosi K Bennett; Sirtaz Adatya
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

3.  2019 EACTS Expert Consensus on long-term mechanical circulatory support.

Authors:  Evgenij V Potapov; Christiaan Antonides; Maria G Crespo-Leiro; Alain Combes; Gloria Färber; Margaret M Hannan; Marian Kukucka; Nicolaas de Jonge; Antonio Loforte; Lars H Lund; Paul Mohacsi; Michiel Morshuis; Ivan Netuka; Mustafa Özbaran; Federico Pappalardo; Anna Mara Scandroglio; Martin Schweiger; Steven Tsui; Daniel Zimpfer; Finn Gustafsson
Journal:  Eur J Cardiothorac Surg       Date:  2019-08-01       Impact factor: 4.191

Review 4.  Facilitating noncardiac surgery for the patient with left ventricular assist device: A guide for the anesthesiologist.

Authors:  Kai-Yin Hwang; Nian-Chih Hwang
Journal:  Ann Card Anaesth       Date:  2018 Oct-Dec
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.