Literature DB >> 26108204

A Non-invasive Real-time Localization System for Enhanced Efficacy in Nasogastric Intubation.

Zhenglong Sun1, Shaohui Foong2, Luc Maréchal1, U-Xuan Tan1, Tee Hui Teo1, Asim Shabbir3.   

Abstract

Nasogastric (NG) intubation is one of the most commonly performed clinical procedures. Real-time localization and tracking of the NG tube passage at the larynx region into the esophagus is crucial for safety, but is lacking in current practice. In this paper, we present the design, analysis and evaluation of a non-invasive real-time localization system using passive magnetic tracking techniques to improve efficacy of the clinical NG intubation process. By embedding a small permanent magnet at the insertion tip of the NG tube, a wearable system containing embedded sensors around the neck can determine the absolute position of the NG tube inside the body in real-time to assist in insertion. In order to validate the feasibility of the proposed system in detecting erroneous tube placement, typical reference intubation trajectories are first analyzed using anatomically correct models and localization accuracy of the system are evaluated using a precise robotic platform. It is found that the root-mean-squared tracking accuracy is within 5.3 mm for both the esophagus and trachea intubation pathways. Experiments were also designed and performed to demonstrate that the system is capable of tracking the NG tube accurately in biological environments even in presence of stationary ferromagnetic objects (such as clinical instruments). With minimal physical modification to the NG tube and clinical process, this system allows accurate and efficient localization and confirmation of correct NG tube placement without supplemental radiographic methods which is considered the current clinical standard.

Keywords:  Healthcare safety; Magnetic localization; Nasogastric intubation; Wearable device

Mesh:

Year:  2015        PMID: 26108204     DOI: 10.1007/s10439-015-1361-0

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  3 in total

1.  High Accuracy Passive Magnetic Field-Based Localization for Feedback Control Using Principal Component Analysis.

Authors:  Shaohui Foong; Zhenglong Sun
Journal:  Sensors (Basel)       Date:  2016-08-12       Impact factor: 3.576

Review 2.  Nasogastric Tube Feeding in Older Patients: A Review of Current Practice and Challenges Faced.

Authors:  Devkishan Chauhan; Surabhi Varma; Melanie Dani; Michael B Fertleman; Louis J Koizia
Journal:  Curr Gerontol Geriatr Res       Date:  2021-01-21

3.  A Low-Cost, Point-of-Care Test for Confirmation of Nasogastric Tube Placement via Magnetic Field Tracking.

Authors:  Muneaki Miyasaka; Hao Li; Kon Voi Tay; Soo Jay Phee
Journal:  Sensors (Basel)       Date:  2021-06-30       Impact factor: 3.576

  3 in total