Literature DB >> 26103935

Determination of methylisothiazolinone and methylchloroisothiazolinone in cosmetic products by ultra high performance liquid chromatography with tandem mass spectrometry.

James B Wittenberg1, Benjamin J Canas1, Wanlong Zhou1, Perry G Wang1, Diego Rua1, Alexander J Krynitsky1.   

Abstract

Isothiazolinone biocides are broad-spectrum preservatives that are widely used in cosmetics, household, and industrial products. An increase in the number of cases of allergic contact dermatitis to isothiazolinone preservatives, namely, methylisothiazolinone and methylchloroisothiazolinone, have been recently noticed. The Food and Drug Administration relies on analytical methods to quantify levels of use of cosmetic ingredients and support enforcement action against products that are not in compliance with the law. In this study, an efficient ultra high performance liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of methylisothiazolinone and methylchloroisothiazolinone in selected cosmetic products. The lower limit of quantitation was determined to be 0.1 μg/g for both preservatives. A survey of 24 cosmetic products was conducted and found concentrations of methylisothiazolinone and methylchloroisothiazolinone ranging from not quantified, or below the lower limit of quantitation, to 89.64 μg/g and not quantified to 10.31 μg/g, respectively.
© 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Cosmetics; Methylchloroisothiazolinone; Methylisothiazolinone; Preservatives

Mesh:

Substances:

Year:  2015        PMID: 26103935     DOI: 10.1002/jssc.201500365

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  4 in total

1.  Development and validation of an analytical method for determination of bronopol and kathon preservative in milk.

Authors:  Amit Chilbule; Richa Singh; Bimlesh Mann; Sumit Arora; Rajan Sharma; Priyanka Singh Rao
Journal:  J Food Sci Technol       Date:  2019-05-16       Impact factor: 2.701

2.  Simultaneous Determination of Isothiazolinones and Parabens in Cosmetic Products Using Solid-Phase Extraction and Ultra-High Performance Liquid Chromatography/Diode Array Detector.

Authors:  Hazim Mohammed Ali; Ibrahim Hotan Alsohaimi; Mohammad Rizwan Khan; Mohammad Azam
Journal:  Pharmaceuticals (Basel)       Date:  2020-11-22

3.  Lichenoid contact dermatitis secondary to methylisothiazolinone (MI).

Authors:  James Raymond; Joseph Konya; Sophie Bakis-Petsoglou
Journal:  JAAD Case Rep       Date:  2016-10-06

4.  Simultaneous Quantitative Analysis of Six Isothiazolinones in Water-Based Adhesive Used for Food Contact Materials by High-Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS).

Authors:  Huaining Zhong; Zicheng Li; Sheng Chen; Ying Zeng; Jianguo Zheng; You Zeng; Dan Li
Journal:  Molecules       Date:  2019-10-29       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.