Literature DB >> 26103131

Accuracy of home versus ambulatory blood pressure monitoring in the diagnosis of white-coat and masked hypertension.

Yuan-Yuan Kang1, Yan Li, Qi-Fang Huang, Jie Song, Xiao-Li Shan, Yu Dou, Xin-Juan Xu, Shou-Hong Chen, Ji-Guang Wang.   

Abstract

BACKGROUND: We investigated accuracy of home blood pressure (BP) monitoring in the diagnosis of white-coat and masked hypertension in comparison with ambulatory BP monitoring.
METHODS: Our study participants were enrolled in the China Ambulatory and Home BP Registry, and underwent clinic, home, and 24-h ambulatory BP measurements. We defined white-coat hypertension as an elevated clinic SBP/DBP (≥140/90 mmHg) and a normal 24-h ambulatory (<130/80 mmHg) or home SBP/DBP (<135/85 mmHg), and masked hypertension as a normal clinic SBP/DBP (<140/90 mmHg) and an elevated 24-h ambulatory (≥130/80 mmHg) or home SBP/DBP (≥135/85 mmHg).
RESULTS: In untreated patients (n = 573), the prevalence of white-coat hypertension (13.1 vs. 19.9%), masked hypertension (17.8 vs. 13.1%), and sustained hypertension (46.4 vs. 39.6%) significantly (P ≤ 0.02) differed between 24-h ambulatory and home BP monitoring. In treated patients (n = 1201), only the prevalence of masked hypertension differed significantly (18.7 vs. 14.5%; P = 0.005). Regardless of the treatment status, home compared with 24-h ambulatory BP had low sensitivity (range 47-74%), but high specificity (86-94%), and accordingly low positive (41-87%), but high negative predictive values (80-94%), and had moderate diagnostic agreement (82-85%) and Kappa statistic (0.41-0.66). In untreated and treated patients, age advancing was associated with a higher prevalence of white-coat hypertension and a lower prevalence of masked hypertension defined by 24-h ambulatory (P ≤ 0.03) but not home BP (P ≥ 0.10).
CONCLUSION: Home BP monitoring has high specificity, but low sensitivity in the diagnosis of white-coat and masked hypertension, and may therefore behave as a complementary to, but not a replacement of, ambulatory BP monitoring.

Entities:  

Mesh:

Year:  2015        PMID: 26103131     DOI: 10.1097/HJH.0000000000000596

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  16 in total

1.  Cardiac hypertrophy in Cushing's syndrome: if not hypertension then what?

Authors:  D A Vassiliadi; S Tsagarakis
Journal:  Endocrine       Date:  2017-02-17       Impact factor: 3.633

Review 2.  The Role of Out-of-Clinic Blood Pressure Measurements in Preventing Hypertension.

Authors:  Yi Chen; Dong-Yan Zhang; Yan Li; Ji-Guang Wang
Journal:  Curr Hypertens Rep       Date:  2018-07-30       Impact factor: 5.369

Review 3.  Home Blood Pressure Monitoring.

Authors:  Jacob George; Thomas MacDonald
Journal:  Eur Cardiol       Date:  2015-12

4.  Twenty-Four-Hour Ambulatory Blood Pressure versus Clinic Blood Pressure Measurements and Risk of Adverse Outcomes in Children with CKD.

Authors:  Elaine Ku; Charles E McCulloch; Bradley A Warady; Susan L Furth; Barbara A Grimes; Mark M Mitsnefes
Journal:  Clin J Am Soc Nephrol       Date:  2018-02-13       Impact factor: 8.237

5.  Masked hypertension in newly diagnosed hypothyroidism: a pilot study.

Authors:  E Piantanida; D Gallo; G Veronesi; N Pariani; E Masiello; P Premoli; L Sassi; A Lai; M L Tanda; M Ferrario; L Bartalena
Journal:  J Endocrinol Invest       Date:  2016-05-19       Impact factor: 4.256

Review 6.  Current status of home blood pressure monitoring in Asia: Statement from the HOPE Asia Network.

Authors:  Yook-Chin Chia; Peera Buranakitjaroen; Chen-Huan Chen; Romeo Divinagracia; Satoshi Hoshide; Sungha Park; Jinho Shin; Saulat Siddique; Jorge Sison; Arieska Ann Soenarta; Guru Prasad Sogunuru; Jam Chin Tay; Yuda Turana; Ji-Guang Wang; Lawrence Wong; Yuqing Zhang; Kazuomi Kario
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-08-17       Impact factor: 3.738

7.  Blood Pressure Measurement Modalities: A Primer for Busy Practitioners.

Authors:  L Allen Kindman; J Rick Turner; John Lee
Journal:  J Clin Hypertens (Greenwich)       Date:  2015-11-12       Impact factor: 3.738

8.  Barriers to blood pressure control in China in a large opportunistic screening.

Authors:  Xin Chen; Shao-Kun Xu; Qian-Hui Guo; Zhe Hu; Hong-Yu Wang; Jing Yu; Wei-Hua Li; Guo-Bao Tang; Hai-Feng Zhang; Yan Li; Ji-Guang Wang
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-04-09       Impact factor: 3.738

Review 9.  2019 Chinese Hypertension League guidelines on home blood pressure monitoring.

Authors:  Ji-Guang Wang; Pei-Li Bu; Lu-Yuan Chen; Xin Chen; Yuan-Yuan Chen; Wen-Li Cheng; Shao-Li Chu; Zhao-Qiang Cui; Qiu-Yan Dai; Ying-Qing Feng; Xiong-Jing Jiang; Yi-Nong Jiang; Wei-Hua Li; Yan Li; Yong Li; Jin-Xiu Lin; Jing Liu; Jian-Jun Mu; Ying-Xin Peng; Lei Song; Ning-Ling Sun; Yan Wang; Yang Xi; Liang-Di Xie; Hao Xue; Jing Yu; Wei Yu; Yu-Qing Zhang; Zhi-Ming Zhu
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-12-31       Impact factor: 3.738

10.  Evaluation of the Accuracy of a New Cuffless Magnetoplethysmography Blood Pressure Monitor in Hypertensive Patients.

Authors:  Sua Kim; Jung Dong Lee; Jeong Bae Park; Seungjin Jang; Jungchae Kim; Sang-Suk Lee
Journal:  Pulse (Basel)       Date:  2018-02-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.