Literature DB >> 26101808

Assessment of Parylene C Thin Films for Heart Valve Tissue Engineering.

Isra Marei1,2,3, Adrian Chester1,2, Ivan Carubelli1, Themistoklis Prodromakis4,5, Tatiana Trantidou4,5, Magdi H Yacoub1,2.   

Abstract

BACKGROUND: Scaffolds are a key component of tissue-engineered heart valves (TEHVs). Several approaches had been adopted in the design of scaffolds using both natural and synthetic resources. We have investigated the suitability of parylene C (PC), a vapor deposited polymeric material, for the use as a scaffold in TEHV. AIMS: To evaluate the adsorption of extracellular matrix components onto plasma-activated PC and study the biocompatibility of PC by measuring cellular adhesion, viability, apoptosis, and phenotypic expression of valve endothelial and interstitial cells. Finally, the mechanical properties of PC were compared with those of native aortic valve cusp tissue.
METHODS: PC slides were plasma activated and then coated with gelatin, type I collagen, or fibronectin. Porcine pulmonary valve endothelial and interstitial cells were then grown on plasma oxidized PC with different types of coatings and their adhesion was observed after 20 h of incubation. Cell viability was tested using the MTS assay, and apoptosis was estimated using TUNEL staining. The mechanical properties of PC and valve tissue were measured using a Bose Mechanical Tester. Finally, cell-seeded PC films were exposed to pulsatile pressure and aortic shear stress, respectively, to test their durability in a dynamic environment.
RESULTS: Our findings show that collagen and fibronectin could bind to plasma oxidized PC. Both valve endothelial and interstitial cells adhered to protein-coated ECM. PC had a profile of mechanical stiffness and ultimate tensile strength that were comparable with or in excess of those seen in porcine aortic valve cusps. Cells were still attached to PC films after 3 days of exposure to up to 50 mmHg pulsatile pressure or aortic levels of shear stress.
CONCLUSION: PC is a promising candidate for use as a scaffold in tissue engineering heart valves. Additional studies are required to determine both the durability and long-term performance of cell-seeded PC when in a similar hemodynamic environment to that of the aortic valve.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26101808      PMCID: PMC4605359          DOI: 10.1089/ten.TEA.2014.0607

Source DB:  PubMed          Journal:  Tissue Eng Part A        ISSN: 1937-3341            Impact factor:   3.845


  23 in total

1.  A nonlinear anisotropic model for porcine aortic heart valves.

Authors:  J Li; X Y Luo; Z B Kuang
Journal:  J Biomech       Date:  2001-10       Impact factor: 2.712

Review 2.  The design of scaffolds for use in tissue engineering. Part I. Traditional factors.

Authors:  S Yang; K F Leong; Z Du; C K Chua
Journal:  Tissue Eng       Date:  2001-12

3.  Minimally-invasive implantation of living tissue engineered heart valves: a comprehensive approach from autologous vascular cells to stem cells.

Authors:  Dörthe Schmidt; Petra E Dijkman; Anita Driessen-Mol; Rene Stenger; Christine Mariani; Arja Puolakka; Marja Rissanen; Thorsten Deichmann; Bernhard Odermatt; Benedikt Weber; Maximilian Y Emmert; Gregor Zund; Frank P T Baaijens; Simon P Hoerstrup
Journal:  J Am Coll Cardiol       Date:  2010-08-03       Impact factor: 24.094

4.  Extracellular matrix production by adipose-derived stem cells: implications for heart valve tissue engineering.

Authors:  Francesca Colazzo; Padmini Sarathchandra; Ryszard T Smolenski; Adrian H Chester; Yuan-Tsan Tseng; Jan T Czernuszka; Magdi H Yacoub; Patricia M Taylor
Journal:  Biomaterials       Date:  2010-11-11       Impact factor: 12.479

5.  Cultured interstitial cells from human heart valves express both specific skeletal muscle and non-muscle markers.

Authors:  Nigel J Brand; Anjana Roy; Ginette Hoare; Adrian Chester; Magdi H Yacoub
Journal:  Int J Biochem Cell Biol       Date:  2005-07-25       Impact factor: 5.085

Review 6.  Substrates for cardiovascular tissue engineering.

Authors:  C V C Bouten; P Y W Dankers; A Driessen-Mol; S Pedron; A M A Brizard; F P T Baaijens
Journal:  Adv Drug Deliv Rev       Date:  2011-01-25       Impact factor: 15.470

7.  Phenotypic and functional characterization of interstitial cells from human heart valves, pericardium and skin.

Authors:  P M Taylor; S P Allen; M H Yacoub
Journal:  J Heart Valve Dis       Date:  2000-01

8.  Differences in tissue-remodeling potential of aortic and pulmonary heart valve interstitial cells.

Authors:  W David Merryman; Jun Liao; Aron Parekh; Joseph E Candiello; Hai Lin; Michael S Sacks
Journal:  Tissue Eng       Date:  2007-09

9.  Cell and protein compatibility of parylene-C surfaces.

Authors:  Tracy Y Chang; Vikramaditya G Yadav; Sarah De Leo; Agustin Mohedas; Bimal Rajalingam; Chia-Ling Chen; Selvapraba Selvarasah; Mehmet R Dokmeci; Ali Khademhosseini
Journal:  Langmuir       Date:  2007-10-04       Impact factor: 3.882

10.  Spatially organized free-standing poly(p-xylylene) nanowires fabricated by vapor deposition.

Authors:  Melik C Demirel; Serhan Boduroglu; Murat Cetinkaya; Akhlesh Lakhtakia
Journal:  Langmuir       Date:  2007-04-28       Impact factor: 3.882

View more
  2 in total

1.  Towards an Implantable, Low Flow Micropump That Uses No Power in the Blocked-Flow State.

Authors:  Dean G Johnson; David A Borkholder
Journal:  Micromachines (Basel)       Date:  2016-06-01       Impact factor: 2.891

2.  Electronics with shape actuation for minimally invasive spinal cord stimulation.

Authors:  Ben J Woodington; Vincenzo F Curto; Yi-Lin Yu; Héctor Martínez-Domínguez; Lawrence Coles; George G Malliaras; Christopher M Proctor; Damiano G Barone
Journal:  Sci Adv       Date:  2021-06-25       Impact factor: 14.136

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.