Masaki Ogawa1, Tatsuya Kawai2, Hirohito Kan2, Susumu Kobayashi3, Yoshihiro Akagawa3, Kazushi Suzuki2, Shunsuke Nojiri4, Yoshiyuki Ozawa2, Yuta Shibamoto2. 1. Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan. eternal@fj9.so-net.ne.jp. 2. Department of Radiology, Nagoya City University Graduate School of Medical Sciences, 1, Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan. 3. Department of Radiology, Toyokawa City Hospital, Toyokawa, Japan. 4. Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan.
Abstract
PURPOSE: We examined whether the shortened breath-hold 3-dimensional volumetric interpolated breath-hold examination (3D-VIBE) sequence for high acceleration factor (AF) using the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) could substitute for the conventional sequence using generalized autocalibrating partially parallel acquisition (GRAPPA) in patients undergoing routine gadoxetic acid-enhanced liver MRI. MATERIALS AND METHODS: Thirty patients with clinically suspected focal liver lesions were scanned using 3D-VIBE sequences with GRAPPA with AF = 2 and AF = 4 and CAIPIRINHA with AF = 4 (acquisition times: 21, 14, and 12 s, respectively) during the hepatobiliary phase. Visual evaluations using a 3- or 5-point scale and signal-to-noise ratio (SNR) analysis were performed for the 3 sequences. RESULTS: For CAIPIRINHA with AF = 4, there was significantly less image noise in both visual evaluation and SNR analysis and fewer parallel imaging artifacts than for GRAPPA with AF = 4 (P < 0.0005); it was equal to GRAPPA with AF = 2 and had fewer motion artifacts than GRAPPA with AF = 2 and 4 (P < 0.0012). The liver edge sharpness and hepatic vessel clarity, lesion conspicuity, and overall image quality were rated significantly higher with CAIPIRINHA with AF = 4 than GRAPPA with AF = 2 and AF = 4 (P < 0.009). For GRAPPA with AF = 4, lesion conspicuity and overall image quality were rated significantly lower than for GRAPPA with AF = 2 (P < 0.012). CONCLUSION: The shortened breath-hold 3D-VIBE sequence using the new CAIPIRINHA technique with a high AF of 4 was superior to the conventional GRAPPA sequence. The shortened breath-hold sequence using GRAPPA with a high AF of 4 worsened the image quality and lesion conspicuity.
PURPOSE: We examined whether the shortened breath-hold 3-dimensional volumetric interpolated breath-hold examination (3D-VIBE) sequence for high acceleration factor (AF) using the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) could substitute for the conventional sequence using generalized autocalibrating partially parallel acquisition (GRAPPA) in patients undergoing routine gadoxetic acid-enhanced liver MRI. MATERIALS AND METHODS: Thirty patients with clinically suspected focal liver lesions were scanned using 3D-VIBE sequences with GRAPPA with AF = 2 and AF = 4 and CAIPIRINHA with AF = 4 (acquisition times: 21, 14, and 12 s, respectively) during the hepatobiliary phase. Visual evaluations using a 3- or 5-point scale and signal-to-noise ratio (SNR) analysis were performed for the 3 sequences. RESULTS: For CAIPIRINHA with AF = 4, there was significantly less image noise in both visual evaluation and SNR analysis and fewer parallel imaging artifacts than for GRAPPA with AF = 4 (P < 0.0005); it was equal to GRAPPA with AF = 2 and had fewer motion artifacts than GRAPPA with AF = 2 and 4 (P < 0.0012). The liver edge sharpness and hepatic vessel clarity, lesion conspicuity, and overall image quality were rated significantly higher with CAIPIRINHA with AF = 4 than GRAPPA with AF = 2 and AF = 4 (P < 0.009). For GRAPPA with AF = 4, lesion conspicuity and overall image quality were rated significantly lower than for GRAPPA with AF = 2 (P < 0.012). CONCLUSION: The shortened breath-hold 3D-VIBE sequence using the new CAIPIRINHA technique with a high AF of 4 was superior to the conventional GRAPPA sequence. The shortened breath-hold sequence using GRAPPA with a high AF of 4 worsened the image quality and lesion conspicuity.
Entities:
Keywords:
3-Dimensional volumetric interpolated breath-hold examination (3D-VIBE); Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA); Gadoxetic acid-enhanced liver MRI; High acceleration factor (AF); Parallel imaging technique; Short breath hold
Authors: Onofrio A Catalano; Lale Umutlu; Niccolo Fuin; Matthew Louis Hibert; Michele Scipioni; Stefano Pedemonte; Mark Vangel; Andreea Maria Catana; Ken Herrmann; Felix Nensa; David Groshar; Umar Mahmood; Bruce R Rosen; Ciprian Catana Journal: Eur J Nucl Med Mol Imaging Date: 2018-07-11 Impact factor: 9.236
Authors: Luigi Grazioli; Riccardo Faletti; Barbara Frittoli; Giacomo Battisti; Roberta Ambrosini; Laura Romanini; Marco Gatti; Paolo Fonio Journal: Radiol Med Date: 2018-08-06 Impact factor: 3.469
Authors: Johannes Budjan; Philipp Riffel; Melissa M Ong; Stefan O Schoenberg; Ulrike I Attenberger; Daniel Hausmann Journal: BMC Med Imaging Date: 2017-05-09 Impact factor: 1.930