Abstract

BACKGROUND: Real time three-dimensional echocardiography (RT3DE) provides a reliable analysis of left ventricular (LV) volume. Despite a wide spectrum of tracking algorithms presently available, which software is most suitable for evaluating functional single left ventricle (FLSV) is unknown. Herein, we compared two of the most commonly used 3DE algorithms for quantification of LV volumes in the pediatric population with FLSV.
METHODS: Thirty-six children with FLSV were prospectively enrolled. The LV volume analysis was performed on QLAB 8.1 (semiautomated border tracking) and TomTec 4D LV 3.0 (manual dominant border tracking) and compared with MRI as the reference standard.
RESULTS: 3DE volume quantification was achieved for 32 children with QLAB and 34 children with TomTec. Analysis time was much shorter for QLAB than TomTec (4.8 ± 1.2 vs. 6.3 ± 1.8 minutes, P < 0.05). Ejection fraction (EF) by either 3DE modality was significantly lower than the published normal values (P < 0.01 for each). End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume, and EF calculated by both 3DE modalities underestimated MRI values. Compared to QLAB, TomTec showed better correlation and smaller intertechnique differences with MRI (the 95% limits of agreement, EDV: -20.84 to 5.18 mL in QLAB, -10.66 to 1.84 mL in TomTec; ESV: -8.94 to 3.07 mL in QLAB, -2.45 to 0.98 mL in TomTec; SV: -13.31 to 3.45 mL in QLAB, -9.34 to 2.0 mL in TomTec; EF: -12.07 to 7.76% in QLAB, -9.64 to 1.52% in TomTec), TomTec was more reproducible with better intraclass correlation coefficients and variation coefficients.
CONCLUSIONS: Both 3DE modalities tend to underestimate LV volumes, but the correlation of LV volumes and EF between 3DE and MRI still holds well. Despite a longer operating time, TomTec analysis is more accurate and reproducible.
© 2015, Wiley Periodicals, Inc.

Entities:  

Keywords:  QLAB; TomTec; functional single ventricle; left ventricular volume

Mesh:

Year:  2015        PMID: 26099327     DOI: 10.1111/echo.12990

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  3 in total

1.  Three-Dimensional Echocardiography in Evaluating LA Volumes and Functions in Diabetic Normotensive Patients without Symptomatic Cardiovascular Disease.

Authors:  Mohamed Hamza; Ahmed Mamdouh; Dina Ezzeldin; Adnan Tawfik; Ahmed Nayel
Journal:  Int J Vasc Med       Date:  2020-08-19

2.  Quantification of ventricular unloading by 3D echocardiography in single ventricle of left ventricular morphology following superior cavo-pulmonary anastomosis and Fontan completion - a feasibility study.

Authors:  Deepa Sasikumar; Bijulal Sasidharan; Baiju S Dharan; Arun Gopalakrishnan; Kavasseri M Krishnamoorthy; Sivasubramanian Sivasankaran
Journal:  Ann Pediatr Cardiol       Date:  2017 Sep-Dec

Review 3.  Three-dimensional echocardiography in adult congenital heart disease.

Authors:  Hyun Suk Yang
Journal:  Korean J Intern Med       Date:  2017-06-30       Impact factor: 2.884

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.