Literature DB >> 26098684

Diagnostic efficacy of 3-D hysterosalpingo-contrast sonography in the detection of tubal occlusion: Systematic meta-analysis.

Jiangxiu Yu1, Mingjin Cai2, Weixiang Liang1, Zhifeng Deng3, Yinong Xie1.   

Abstract

AIM: Evaluation of tubal status is critical in the diagnostic work-up of infertile women. The purpose of this study was to explore the diagnostic efficacy of three-dimensional hysterosalpingo-contrast sonography (3-D HyCoSy) for tubal occlusion.
METHODS: MedLine, Embase, Cochrane Library, ScienceDirect, CNKI, Chinese VIP Database, Chinese Wanfang Database and Chinese Biomedicine Database were searched for relevant trials published from June 1994 to August 2013. Meta-DiSc (version 1.4) was used for the meta-analysis. Diagnostic accuracy was determined by pooled estimates of sensitivity and specificity, as well as area under the curve (AUC) and the pooled diagnostic accuracy (Q*) derived from a summary receiver operating characteristic analysis. The heterogeneity test was done using the Cochran Q statistic and the I(2) statistic. Significant difference was defined as P < 0.10 (Q-statistic) or I(2) > 50% (I(2) -statistic) and a random effect model was used to pool data, otherwise the fixed effects model was used.
RESULTS: A total of 11 studies (1037 Fallopian tubes) were included in this meta-analysis. The pooled estimates for diagnostic efficacy of 3-D HyCoSy had a sensitivity of 0.92 (95%CI: 0.89-0.94) and specificity of 0.95 (95%CI: 0.93-0.96). AUC and Q* were 0.976 and 0.929, respectively, but there was significant heterogeneity in sensitivity across the included studies.
CONCLUSIONS: 3-D HyCoSy had good diagnostic performance in the detection of tubal occlusion.
© 2015 Japan Society of Obstetrics and Gynecology.

Entities:  

Keywords:  meta-analysis; three-dimensional hysterosalpingo-contrast sonography; tubal occlusion

Mesh:

Substances:

Year:  2015        PMID: 26098684     DOI: 10.1111/jog.12728

Source DB:  PubMed          Journal:  J Obstet Gynaecol Res        ISSN: 1341-8076            Impact factor:   1.730


  2 in total

1.  Operator's Influence on Contrast Agent Intravasation During Hysterosalpingo-Contrast Sonography: Explanation Based on a Physics Model.

Authors:  Bin-Bin Jin; Yan Ma; Xiu-Hua Zhao; Yi-Ling Teng; Shang-Yong Zhu
Journal:  Int J Gen Med       Date:  2022-10-07

2.  Development of a Nomogram for Predicting Intravasation Before Transvaginal 4-Dimensional Hysterosalpingo-Contrast Sonography.

Authors:  Yi Jin; Wendi Huang; Qinhong Qv; Shuling Liu
Journal:  Int J Womens Health       Date:  2022-04-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.