F Slaghekke1, S Pasman2, M Veujoz3, J M Middeldorp1, L Lewi2, R Devlieger2, R Favre3, E Lopriore4, D Oepkes1. 1. Department of Obstetrics, Leiden University Medical Centre, Leiden, The Netherlands. 2. Department of Obstetrics and Gynecology, University Hospitals KU Leuven, Leuven, Belgium. 3. Department of Obstetrics, University Hospital CMCO-HUS, Strasbourg, France. 4. Department of Neonatology, Leiden University Medical Centre, Leiden, The Netherlands.
Abstract
OBJECTIVE: To evaluate the diagnostic accuracy of middle cerebral artery peak systolic velocity (MCA-PSV) Doppler measurements in prediction of hemoglobin levels in twin anemia-polycythemia sequence (TAPS). METHODS: This study involved a consecutive cohort comprising monochorionic twin pregnancies complicated by TAPS managed at three European fetal medicine centers between 2005 and 2013. The accuracy of MCA-PSV, measured immediately prior to fetal hemoglobin (Hb) measurement by fetal or cord blood sampling, for prediction of anemia and polycythemia was assessed using 2 × 2 tables. RESULTS: A total of 116 measurements (74 recorded in donors and 42 in recipients) from 43 twin pregnancies complicated by TAPS were available for analysis. MCA-PSV multiples of the median (MoM) values correlated well with Hb levels (r = - 0.86; P < 0.001). The sensitivity of MCA-PSV ≥ 1.5 MoM to predict severe anemia (Hb deficit > 5 SD below the mean) in TAPS donors was 94% (95% CI, 85-98%); specificity was 74% (95% CI, 62-83%); positive and negative predictive values were 76% (95% CI, 65-85%) and 94% (95% CI, 83-98%), respectively. The sensitivity of MCA-PSV ≤ 1.0 MoM to predict polycythemia (Hb level > 5 SD above the mean) in TAPS recipients was 97% (95% CI, 87-99%); specificity was 96% (95% CI, 89-99%); positive and negative predictive values were 93% (95% CI, 81-97%) and 99% (95% CI, 93-100%), respectively. CONCLUSION: MCA-PSV measurement has high diagnostic accuracy for predicting abnormal Hb levels in fetuses with TAPS.
OBJECTIVE: To evaluate the diagnostic accuracy of middle cerebral artery peak systolic velocity (MCA-PSV) Doppler measurements in prediction of hemoglobin levels in twin anemia-polycythemia sequence (TAPS). METHODS: This study involved a consecutive cohort comprising monochorionic twin pregnancies complicated by TAPS managed at three European fetal medicine centers between 2005 and 2013. The accuracy of MCA-PSV, measured immediately prior to fetal hemoglobin (Hb) measurement by fetal or cord blood sampling, for prediction of anemia and polycythemia was assessed using 2 × 2 tables. RESULTS: A total of 116 measurements (74 recorded in donors and 42 in recipients) from 43 twin pregnancies complicated by TAPS were available for analysis. MCA-PSV multiples of the median (MoM) values correlated well with Hb levels (r = - 0.86; P < 0.001). The sensitivity of MCA-PSV ≥ 1.5 MoM to predict severe anemia (Hb deficit > 5 SD below the mean) in TAPS donors was 94% (95% CI, 85-98%); specificity was 74% (95% CI, 62-83%); positive and negative predictive values were 76% (95% CI, 65-85%) and 94% (95% CI, 83-98%), respectively. The sensitivity of MCA-PSV ≤ 1.0 MoM to predict polycythemia (Hb level > 5 SD above the mean) in TAPS recipients was 97% (95% CI, 87-99%); specificity was 96% (95% CI, 89-99%); positive and negative predictive values were 93% (95% CI, 81-97%) and 99% (95% CI, 93-100%), respectively. CONCLUSION: MCA-PSV measurement has high diagnostic accuracy for predicting abnormal Hb levels in fetuses with TAPS.
Authors: L S A Tollenaar; F Slaghekke; L Lewi; Y Ville; M Lanna; A Weingertner; G Ryan; S Arévalo; A Khalil; C O Brock; P Klaritsch; K Hecher; G Gardener; E Bevilacqua; K V Kostyukov; M O Bahtiyar; M D Kilby; E Tiblad; D Oepkes; E Lopriore Journal: Ultrasound Obstet Gynecol Date: 2020-09 Impact factor: 7.299