Literature DB >> 26093242

Design of ultraviolet wavelength and standard solution concentrations in relative response factors for simultaneous determination of multi-components with single reference standard in herbal medicines.

Ting-Wen Yang1, Chao Zhao1, Yong Fan1, Lian-Wen Qi2, Ping Li3.   

Abstract

Single standard to determine multi-components (SSDMC) is a practical pattern for quality evaluation of herbal medicines (HMs). However, it remains challenging because of potential inconsistency of relative response factors (RRF) on different instruments. In this work, the effects of two key roles, i.e., ultraviolet (UV) wavelength and standard solution concentrations, on reproducibility of RRF were investigated. The effect of UV wavelength on reproducibility of RRF was studied by plotting the relationship of the peak area ratios (internal standard vs analyte) to wavelengths. The preferable wavelength should be set at the flat parts of the curve. Optimized 300 nm produced a 0.38% RSD for emodin/emodin-8-O-β-D-glucopyranoside on five instruments, much lower than 2.80% obtained from the maximum wavelength at 290 nm. Next, the effects of standard solution concentrations of emodin on its response factor (RF) were investigated. For one single point method, low concentration less than 49 b/k resulted in significant variations in RF. For emodin, when the concentration is higher than 7.00 μg mL(-1), a low standard deviation (SD) value at 0.13 was obtained, while lower than 7.00 μg mL(-1), a high SD at 3.71 was obtained. The developed SSDMC method was then applied to determination of target components in 10 Polygonum cuspidatum samples and showed comparable accuracy to conventional calibration methods with deviation less than 1%.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Polygonum cuspidatum; Relative response factor; Single standard to determine multi-components; Standard solution concentration; Ultraviolet detection wavelength

Mesh:

Substances:

Year:  2015        PMID: 26093242     DOI: 10.1016/j.jpba.2015.05.028

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

Review 1.  A holistic strategy for quality and safety control of traditional Chinese medicines by the "iVarious" standard system.

Authors:  Anzhen Chen; Lei Sun; Hang Yuan; Aiying Wu; Jingguang Lu; Shuangcheng Ma
Journal:  J Pharm Anal       Date:  2017-07-14

2.  A Mass Spectrometry Based Metabolite Profiling Workflow for Selecting Abundant Specific Markers and Their Structurally Related Multi-Component Signatures in Traditional Chinese Medicine Multi-Herb Formulae.

Authors:  Joëlle Houriet; Pierre-Marie Allard; Emerson Ferreira Queiroz; Laurence Marcourt; Arnaud Gaudry; Lennie Vallin; Songhua Li; Yu Lin; Ruwei Wang; Kenny Kuchta; Jean-Luc Wolfender
Journal:  Front Pharmacol       Date:  2020-12-03       Impact factor: 5.810

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.