Literature DB >> 26093123

Kinetic studies of microfabricated biosensors using local adsorption strategy.

Menglun Zhang1, Jingze Huang1, Weiwei Cui1, Wei Pang1, Hao Zhang2, Daihua Zhang1, Xuexin Duan3.   

Abstract

Micro/nano scale biosensors integrated with the local adsorption mask have been demonstrated to have a better limit of detection (LOD) and less sample consumptions. However, the molecular diffusions and binding kinetics in such confined droplet have been less studied which limited further development and application of the local adsorption method and imposed restrictions on discovery of new signal amplification strategies. In this work, we studied the kinetic issues via experimental investigations and theoretical analysis on microfabricated biosensors. Mass sensitive film bulk acoustic resonator (FBAR) sensors with hydrophobic Teflon film covering the non-sensing area as the mask were introduced. The fabricated masking sensors were characterized with physical adsorption of bovine serum albumin (BSA) and specific binding of antibody and antigen. Over an order of magnitude improvement on LOD was experimentally monitored. An analytical model was introduced to discuss the target molecule diffusion and binding kinetics in droplet environment, especially the crucial effects of incubation time, which has been less covered in previous local adsorption related literatures. An incubation time accumulated signal amplification effect was theoretically predicted, experimentally monitored and carefully explained. In addition, device optimization was explored based on the analytical model to fully utilize the merits of local adsorption. The discussions on the kinetic issues are believed to have wide implications for other types of micro/nano fabricated biosensors with potentially improved LOD.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Binding kinetics; Biosensor; FBAR; Local adsorption; Signal amplification

Mesh:

Substances:

Year:  2015        PMID: 26093123     DOI: 10.1016/j.bios.2015.05.061

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Selective Functionalization with PNA of Silicon Nanowires on Silicon Oxide Substrates.

Authors:  Janneke Veerbeek; Raymond Steen; Wouter Vijselaar; W Frederik Rurup; Saša Korom; Andrea Rozzi; Roberto Corradini; Loes Segerink; Jurriaan Huskens
Journal:  Langmuir       Date:  2018-09-12       Impact factor: 3.882

2.  The High Q Factor Lateral Field⁻Excited Thickness Shear Mode Film Bulk Acoustic Resonator Working in Liquid.

Authors:  Da Chen; Wenwen Ren; Shuren Song; Jingjing Wang; Weihui Liu; Peng Wang
Journal:  Micromachines (Basel)       Date:  2016-12-14       Impact factor: 2.891

3.  Micro-Electromechanical Acoustic Resonator Coated with Polyethyleneimine Nanofibers for the Detection of Formaldehyde Vapor.

Authors:  Da Chen; Lei Yang; Wenhua Yu; Maozeng Wu; Wei Wang; Hongfei Wang
Journal:  Micromachines (Basel)       Date:  2018-02-01       Impact factor: 2.891

  3 in total