Literature DB >> 26092700

Ultrasonographic fetometry formulas of inner chorionic cavity diameter and biparietal diameter for medium-sized dogs can be used in giant breeds.

Piotr Socha1, Tomasz Janowski2, Agata Bancerz-Kisiel3.   

Abstract

The aim of this study was to evaluate the suitability of the ultrasonographic fetometry method, involving inner chorionic cavity diameter (ICC) and biparietal diameter (BP) measurements, to predict the parturition date in giant breed dogs. Overall, 30 ICC and 24 BP measurements were taken on 24 giant breed bitches. The measured values were substituted into Luvoni and Grioni (2000) formulas for medium-sized bitches because formulas with ICC and BP to dogs with a body mass greater than 40 kg have not been defined. The accuracy of the parturition date predictions proved the method to be highly useful in the observed group of dogs. Prediction accuracy in the giants ranged between 54.16% (± 1 day, using BP) and 90% (± 2 days, using ICC), depending on the parameter measured and precision levels used. Numerically, the results obtained using ICC were better; however, no statistically significant differences between ICC and BP accuracy were found when comparing the effectiveness of the parturition date predictions. Regression lines based on the own fetometric measurements were highly convergent with the lines defined by Luvoni and Grioni (2000) formulas for medium-sized bitches. This outcome suggests a similar gestational development of fetuses in giant dogs and the possible use of Luvoni and Grioni (2000) formulas for medium-sized dogs with breeds weighing greater than 40 kg.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Bitch; Delivery; Parturition; Pregnancy; Ultrasonography

Mesh:

Year:  2015        PMID: 26092700     DOI: 10.1016/j.theriogenology.2015.05.012

Source DB:  PubMed          Journal:  Theriogenology        ISSN: 0093-691X            Impact factor:   2.740


  2 in total

1.  Support vector regression algorithm modeling to predict the parturition date of small - to medium-sized dogs using maternal weight and fetal biparietal diameter.

Authors:  Thanida Sananmuang; Kanchanarat Mankong; Suppawiwat Ponglowhapan; Kaj Chokeshaiusaha
Journal:  Vet World       Date:  2021-04-02

Review 2.  Usefulness of Maternal and Fetal Parameters for the Prediction of Parturition Date in Dogs.

Authors:  Giulia Siena; Chiara Milani
Journal:  Animals (Basel)       Date:  2021-03-19       Impact factor: 2.752

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.