Literature DB >> 26092660

A technique for semiautomatic segmentation of echogenic structures in 3D ultrasound, applied to infant hip dysplasia.

Abhilash Rakkunedeth Hareendranathan1, Myles Mabee2, Kumaradevan Punithakumar2, Michelle Noga2, Jacob L Jaremko2.   

Abstract

PURPOSE: Automatic segmentation of anatomical structures and lesions from medical ultrasound images is a formidable challenge in medical imaging due to image noise, blur and artifacts. In this paper we present a segmentation technique with features highly suited to use in noisy 3D ultrasound volumes and demonstrate its use in modeling bone, specifically the acetabulum in infant hips. Quantification of the acetabular shape is crucial in diagnosing developmental dysplasia of the hip (DDH), a common condition associated with hip dislocation and premature osteoarthritis if not treated. The well-established Graf technique for DDH diagnosis has been criticized for high inter-observer and inter-scan variability. In our earlier work we have introduced a more reliable instability metric based on 3D ultrasound data. Visualizing and interpreting the acetabular shape from noisy 3D ultrasound volumes has been one of the major roadblocks in using 3D ultrasound as diagnostic tool for DDH. For this study we developed a semiautomated segmentation technique to rapidly generate 3D acetabular surface models and classified the acetabulum based on acetabular contact angle (ACA) derived from the models. We tested the feasibility and reliability of the technique compared with manual segmentation.
METHODS: The proposed segmentation algorithm is based on graph search. We formulate segmentation of the acetabulum as an optimal path finding problem on an undirected weighted graph. Slice contours are defined as the optimal path passing through a set of user-defined seed points in the graph, and it can be found using dynamic programming techniques (in this case Dijkstra's algorithm). Slice contours are then interpolated over the 3D volume to generate the surface model. A three-dimensional ACA was calculated using normal vectors of the surface model.
RESULTS: The algorithm was tested over an extensive dataset of 51 infant ultrasound hip volumes obtained from 42 subjects with normal to dysplastic hips. The contours generated by the segmentation algorithm closely matched with those obtained from manual segmentation. The average RMS errors between the semiautomated and manual segmentation for the 51 volumes were 0.28 mm/1.1 voxel (with 2 node points) and 0.24 mm/0.9 voxel (with 3 node points). The semiautomatic algorithm gave visually acceptable results on images with moderate levels of noise and was able to trace the boundary of the acetabulum even in the presence of significant shadowing. Semiautomatic contouring was also faster than manual segmentation at 37 versus 56 s per scan. It also improved the repeatability of the ACA calculation with inter-observer and intra-observer variability of 1.4 ± 0.9 degree and 1.4 ± 1.0 degree.
CONCLUSION: The semiautomatic segmentation technique proposed in this work offers a fast and reliable method to delineate the contours of the acetabulum from 3D ultrasound volumes of the hip. Since the technique does not rely upon contour evolution, it is less susceptible than other methods to the frequent missing or incomplete boundaries and noise artifacts common in ultrasound images. ACA derived from the segmented 3D surface was able to accurately classify the acetabulum under the categories normal, borderline and dysplastic. The semiautomatic technique makes it easier to segment the volume and reduces the inter-observer and intra-observer variation in ACA calculation compared with manual segmentation. The method can be applied to any structure with an echogenic boundary on ultrasound (such as a ventricle, blood vessel, organ or tumor), or even to structures with a bright border on computed tomography or magnetic resonance imaging.

Entities:  

Keywords:  3D Musculoskeletal ultrasound; Developmental dysplasia of the hip (DDH); Graph-search-based segmentation; Semiautomatic segmentation

Mesh:

Year:  2015        PMID: 26092660     DOI: 10.1007/s11548-015-1239-5

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  17 in total

1.  An ultra-fast user-steered image segmentation paradigm: live wire on the fly.

Authors:  A X Falcão; J K Udupa; F K Miyazawa
Journal:  IEEE Trans Med Imaging       Date:  2000-01       Impact factor: 10.048

2.  Atlas-based segmentation of bone structures to support the virtual planning of hip operations.

Authors:  J Ehrhardt; H Handels; T Malina; B Strathmann; W Plötz; S J Pöppl
Journal:  Int J Med Inform       Date:  2001-12       Impact factor: 4.046

3.  Automated segmentation of necrotic femoral head from 3D MR data.

Authors:  Reza A Zoroofi; Yoshinobu Sato; Takashi Nishii; Nobuhiko Sugano; Hideki Yoshikawa; Shinichi Tamura
Journal:  Comput Med Imaging Graph       Date:  2004-07       Impact factor: 4.790

4.  Automated segmentation of the femur and pelvis from 3D CT data of diseased hip using hierarchical statistical shape model of joint structure.

Authors:  Futoshi Yokota; Toshiyuki Okada; Masaki Takao; Nobuhiko Sugano; Yukio Tada; Yoshinobu Sato
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

5.  Optimal surface segmentation in volumetric images--a graph-theoretic approach.

Authors:  Kang Li; Xiaodong Wu; Danny Z Chen; Milan Sonka
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2006-01       Impact factor: 6.226

6.  Random walks for image segmentation.

Authors:  Leo Grady
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2006-11       Impact factor: 6.226

7.  Reproducibility of Acetabular Landmarks and a Standardized Coordinate System Obtained from 3D Hip Ultrasound.

Authors:  Myles Mabee; Sukhdeep Dulai; Richard B Thompson; Jacob L Jaremko
Journal:  Ultrason Imaging       Date:  2014-11-13       Impact factor: 1.578

8.  Fundamentals of sonographic diagnosis of infant hip dysplasia.

Authors:  R Graf
Journal:  J Pediatr Orthop       Date:  1984-11       Impact factor: 2.324

9.  Hip disease and the prognosis of total hip replacements. A review of 53,698 primary total hip replacements reported to the Norwegian Arthroplasty Register 1987-99.

Authors:  O Furnes; S A Lie; B Espehaug; S E Vollset; L B Engesaeter; L I Havelin
Journal:  J Bone Joint Surg Br       Date:  2001-05

10.  Potential for change in US diagnosis of hip dysplasia solely caused by changes in probe orientation: patterns of alpha-angle variation revealed by using three-dimensional US.

Authors:  Jacob L Jaremko; Myles Mabee; Vimarsha G Swami; Lucy Jamieson; Kelvin Chow; Richard B Thompson
Journal:  Radiology       Date:  2014-06-25       Impact factor: 11.105

View more
  10 in total

1.  An automatic segmentation method of a parameter-adaptive PCNN for medical images.

Authors:  Jing Lian; Bin Shi; Mingcong Li; Ziwei Nan; Yide Ma
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-05-05       Impact factor: 2.924

2.  Automatic gallbladder and gallstone regions segmentation in ultrasound image.

Authors:  Jing Lian; Yide Ma; Yurun Ma; Bin Shi; Jizhao Liu; Zhen Yang; Yanan Guo
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-01-06       Impact factor: 2.924

3.  Semiautomatic classification of acetabular shape from three-dimensional ultrasound for diagnosis of infant hip dysplasia using geometric features.

Authors:  Abhilash Rakkunedeth Hareendranathan; Dornoosh Zonoobi; Myles Mabee; Chad Diederichs; Kumaradevan Punithakumar; Michelle Noga; Jacob L Jaremko
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-12-26       Impact factor: 2.924

Review 4.  Narrative Review on the Role of Imaging in DDH.

Authors:  Siyavash Ghasseminia; Abhilash Rakkunedeth Hareendranathan; Jacob L Jaremko
Journal:  Indian J Orthop       Date:  2021-10-11       Impact factor: 1.033

5.  Artificial Intelligence to Automatically Assess Scan Quality in Hip Ultrasound.

Authors:  Abhilash Rakkundeth Hareendranathan; Baljot S Chahal; Dornoosh Zonoobi; Dulai Sukhdeep; Jacob L Jaremko
Journal:  Indian J Orthop       Date:  2021-07-17       Impact factor: 1.033

6.  Impact of scan quality on AI assessment of hip dysplasia ultrasound.

Authors:  Abhilash Rakkundeth Hareendranathan; Baljot Chahal; Siyavash Ghasseminia; Dornoosh Zonoobi; Jacob L Jaremko
Journal:  J Ultrasound       Date:  2021-03-05

7.  Fully Automated Segmentation of Bladder Sac and Measurement of Detrusor Wall Thickness from Transabdominal Ultrasound Images.

Authors:  Zeynettin Akkus; Bae Hyung Kim; Rohit Nayak; Adriana Gregory; Azra Alizad; Mostafa Fatemi
Journal:  Sensors (Basel)       Date:  2020-07-27       Impact factor: 3.576

Review 8.  Four decades of developmental dysplastic hip screening according to Graf: What have we learned?

Authors:  Sebastian G Walter; Robert Ossendorff; Ayla Yagdiran; Jan Hockmann; Rahel Bornemann; Sonja Placzek
Journal:  Front Pediatr       Date:  2022-09-15       Impact factor: 3.569

9.  Artificial intelligence in musculoskeletal ultrasound imaging.

Authors:  YiRang Shin; Jaemoon Yang; Young Han Lee; Sungjun Kim
Journal:  Ultrasonography       Date:  2020-09-06

10.  Three-dimensional ultrasound for knee osteophyte depiction: a comparative study to computed tomography.

Authors:  Valeria Vendries; Tamas Ungi; Jordan Harry; Manuela Kunz; Jana Podlipská; Les MacKenzie; Gabriel Venne
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-07-27       Impact factor: 2.924

  10 in total