Literature DB >> 26092337

Sensitive and selective magnetoimmunosensing platform for determination of the food allergen Ara h 1.

V Ruiz-Valdepeñas Montiel1, S Campuzano2, A Pellicanò3, R M Torrente-Rodríguez4, A J Reviejo5, M S Cosio6, J M Pingarrón7.   

Abstract

A highly sensitive disposable amperometric immunosensor based on the use of magnetic beads (MBs) is described for determination of Ara h 1, the major peanut allergen, in only 2h. The approach uses a sandwich configuration involving selective capture and biotinylated detector antibodies and carboxylic acid-modified MBs (HOOC-MBs). The MBs bearing the immunoconjugates are captured by a magnet placed under the surface of a disposable screen-printed carbon electrode (SPCE) and the affinity reactions are monitored amperometrically at -0.20 V (vs a Ag pseudo-reference electrode) in the presence of hydroquinone (HQ) as electron transfer mediator and upon addition of H2O2 as the enzyme substrate. The developed immunosensor exhibits a wide range of linearity between 20.8 and 1000.0 ng mL(-1) Ara h 1, a detection limit of 6.3 ng mL(-1), a great selectivity, a good reproducibility with a RSD of 6.3% for six different immunosensors and a useful lifetime of 25 days. The usefulness of the immunosensor was demonstrated by determining Ara h 1 in different matrices (food extracts and saliva). The results correlated properly with those provided by a commercial ELISA method offering a reliable and promising analytical screening tool in the development of user-friendly devices for on-site determination of Ara h 1.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Amperometric immunosensor; Ara h 1; Food extracts; Magnetic beads; Saliva; Screen-printed electrode

Mesh:

Substances:

Year:  2015        PMID: 26092337     DOI: 10.1016/j.aca.2015.04.041

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  8 in total

Review 1.  Standardization and Regulation of Allergen Products in the European Union.

Authors:  Julia Zimmer; Stefan Vieths; Susanne Kaul
Journal:  Curr Allergy Asthma Rep       Date:  2016-03       Impact factor: 4.806

Review 2.  Magnetic nanoparticles for smart electrochemical immunoassays: a review on recent developments.

Authors:  Matěj Pastucha; Zdeněk Farka; Karel Lacina; Zuzana Mikušová; Petr Skládal
Journal:  Mikrochim Acta       Date:  2019-04-29       Impact factor: 5.833

Review 3.  Recent Advances in Electrochemical Sensing Strategies for Food Allergen Detection.

Authors:  Antonella Curulli
Journal:  Biosensors (Basel)       Date:  2022-07-09

4.  Tracking Arachis hypogaea Allergen in Pre-Packaged Foodstuff: A Nanodiamond-Based Electrochemical Biosensing Approach.

Authors:  Maria Freitas; André Carvalho; Henri P A Nouws; Cristina Delerue-Matos
Journal:  Biosensors (Basel)       Date:  2022-06-18

Review 5.  Electrochemical Affinity Biosensors Based on Disposable Screen-Printed Electrodes for Detection of Food Allergens.

Authors:  Alina Vasilescu; Gilvanda Nunes; Akhtar Hayat; Usman Latif; Jean-Louis Marty
Journal:  Sensors (Basel)       Date:  2016-11-05       Impact factor: 3.576

6.  Electrochemical sensor for rapid determination of fibroblast growth factor receptor 4 in raw cancer cell lysates.

Authors:  Rebeca M Torrente-Rodríguez; Víctor Ruiz-Valdepeñas Montiel; Susana Campuzano; María Pedrero; Meryem Farchado; Eva Vargas; F Javier Manuel de Villena; María Garranzo-Asensio; Rodrigo Barderas; José M Pingarrón
Journal:  PLoS One       Date:  2017-04-04       Impact factor: 3.240

7.  Voltammetric Immunosensor to Track a Major Peanut Allergen (Ara h 1) in Food Products Employing Quantum Dot Labels.

Authors:  Maria Freitas; Henri P A Nouws; Cristina Delerue-Matos
Journal:  Biosensors (Basel)       Date:  2021-10-29

Review 8.  Magnetic Particles Coupled to Disposable Screen Printed Transducers for Electrochemical Biosensing.

Authors:  Paloma Yáñez-Sedeño; Susana Campuzano; José M Pingarrón
Journal:  Sensors (Basel)       Date:  2016-09-25       Impact factor: 3.576

  8 in total