Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

Monica Sethi1, Jonathan Zagzag2, Karan Patel2, Melissa Magrath2, Eduardo Somoza2, Manish S Parikh2, John K Saunders2, Aku Ude-Welcome2, Bradley F Schwack2, Marina S Kurian2, George A Fielding2, Christine J Ren-Fielding2.   

Abstract

BACKGROUND: Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy.
METHODS: A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses.
RESULTS: A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative.
CONCLUSION: Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

Entities:  

Keywords:  Fistula; Intraoperative leak test; Leak; Methylene blue; Sleeve gastrectomy; Staple line

Mesh:

Year:  2015        PMID: 26092015     DOI: 10.1007/s00464-015-4286-7

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  30 in total

1.  A very challenging leak from a sleeve gastrectomy.

Authors:  Sheila Jen; Constantinos Simillis; Evangelos Efthimiou
Journal:  Surg Obes Relat Dis       Date:  2012-06-15       Impact factor: 4.734

2.  Palmar staining following methylene blue leak test during laparoscopic Roux-en-Y gastric bypass.

Authors:  Iswanto Sucandy; Samuel Szomstein; Raul J Rosenthal
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2010 Jul-Aug       Impact factor: 1.878

3.  Nonsurgical treatment of staple line leaks after laparoscopic sleeve gastrectomy.

Authors:  G Casella; E Soricelli; M Rizzello; P Trentino; F Fiocca; A Fantini; F M Salvatori; N Basso
Journal:  Obes Surg       Date:  2009-04-21       Impact factor: 4.129

4.  Survey on laparoscopic sleeve gastrectomy (LSG) at the Fourth International Consensus Summit on Sleeve Gastrectomy.

Authors:  Michel Gagner; Mervyn Deitel; Ann L Erickson; Ross D Crosby
Journal:  Obes Surg       Date:  2013-12       Impact factor: 4.129

5.  The Second International Consensus Summit for Sleeve Gastrectomy, March 19-21, 2009.

Authors:  Michel Gagner; Mervyn Deitel; Traci L Kalberer; Ann L Erickson; Ross D Crosby
Journal:  Surg Obes Relat Dis       Date:  2009-06-13       Impact factor: 4.734

6.  Intraoperative endoscopy and leaks after laparoscopic Roux-en-Y gastric bypass.

Authors:  Diya Alaedeen; Atul K Madan; Charles Y Ro; Khurram A Khan; Jose M Martinez; David S Tichansky
Journal:  Am Surg       Date:  2009-06       Impact factor: 0.688

7.  Practice of routine intraoperative leak test during laparoscopic sleeve gastrectomy should not be discarded.

Authors:  Sandeep Aggarwal; Hemanga Bhattacharjee; Mahesh Chander Misra
Journal:  Surg Obes Relat Dis       Date:  2011-04-15       Impact factor: 4.734

Review 8.  Surgical strategies that may decrease leak after laparoscopic sleeve gastrectomy: a systematic review and meta-analysis of 9991 cases.

Authors:  Manish Parikh; Reda Issa; Aileen McCrillis; John K Saunders; Aku Ude-Welcome; Michel Gagner
Journal:  Ann Surg       Date:  2013-02       Impact factor: 12.969

9.  Laparoscopic sleeve gastrectomy, 529 cases without a leak: short-term results and technical considerations.

Authors:  Drake Eric Bellanger; Frank L Greenway
Journal:  Obes Surg       Date:  2011-02       Impact factor: 4.129

10.  Gastric leaks after sleeve gastrectomy: a multicenter experience with 2,834 patients.

Authors:  Nasser Sakran; David Goitein; Asnat Raziel; Andrei Keidar; Nahum Beglaibter; Ronit Grinbaum; Ibrahim Matter; Ricardo Alfici; Ahmad Mahajna; Igor Waksman; Mordechai Shimonov; Ahmad Assalia
Journal:  Surg Endosc       Date:  2012-06-30       Impact factor: 4.584

View more
  18 in total

Review 1.  Emerging Trends in the Etiology, Prevention, and Treatment of Gastrointestinal Anastomotic Leakage.

Authors:  Sami A Chadi; Abe Fingerhut; Mariana Berho; Steven R DeMeester; James W Fleshman; Neil H Hyman; David A Margolin; Joseph E Martz; Elisabeth C McLemore; Daniela Molena; Martin I Newman; Janice F Rafferty; Bashar Safar; Anthony J Senagore; Oded Zmora; Steven D Wexner
Journal:  J Gastrointest Surg       Date:  2016-09-16       Impact factor: 3.452

Review 2.  Canadian consensus statement: enhanced recovery after surgery in bariatric surgery.

Authors:  Jerry T Dang; Vivian G Szeto; Ahmad Elnahas; James Ellsmere; Allan Okrainec; Amy Neville; Samaad Malik; Ekua Yorke; Dennis Hong; Laurent Biertho; Timothy Jackson; Shahzeer Karmali
Journal:  Surg Endosc       Date:  2019-06-17       Impact factor: 4.584

3.  Staple Line Reinforcement in Laparoscopic SleeveGastrectomy: Experience in 1023 Consecutive Cases.

Authors:  Matías Sepúlveda; Cristián Astorga; Juan P Hermosilla; Munir Alamo
Journal:  Obes Surg       Date:  2017-06       Impact factor: 4.129

4.  Technique of air-leak testing of ileocolic anastomosis.

Authors:  T Poskus; M Luksta; M Kryzauskas
Journal:  Tech Coloproctol       Date:  2018-11-19       Impact factor: 3.781

5.  Laparoscopic Sleeve Gastrectomy for Morbid Obesity in 3003 Patients: Results at a High-Volume Bariatric Center.

Authors:  Nasser Sakran; Asnat Raziel; Orly Goitein; Amir Szold; David Goitein
Journal:  Obes Surg       Date:  2016-09       Impact factor: 4.129

Review 6.  Leaks after laparoscopic sleeve gastrectomy: overview of pathogenesis and risk factors.

Authors:  Angelo Iossa; Mohamed Abdelgawad; Brad Michael Watkins; Gianfranco Silecchia
Journal:  Langenbecks Arch Surg       Date:  2016-06-15       Impact factor: 3.445

7.  Perioperative Practices Concerning Sleeve Gastrectomy - a Survey of 863 Surgeons with a Cumulative Experience of 520,230 Procedures.

Authors:  Md Tanveer Adil; Ali Aminian; Aparna Govil Bhasker; Reynu Rajan; Ricard Corcelles; Carlos Zerrweck; Yitka Graham; Kamal Mahawar
Journal:  Obes Surg       Date:  2020-02       Impact factor: 4.129

8.  Comparison Between Stable Line Reinforcement by Barbed Suture and Non-reinforcement in Sleeve Gastrectomy: a Randomized Prospective Controlled Study.

Authors:  Mohamed Hany; Mohammed Ibrahim
Journal:  Obes Surg       Date:  2018-08       Impact factor: 4.129

9.  Management of Staple Line Leaks Following Sleeve Gastrectomy-a Systematic Review.

Authors:  Daniel Hughes; Ioan Hughes; Achal Khanna
Journal:  Obes Surg       Date:  2019-09       Impact factor: 4.129

10.  Shorter than 24-h hospital stay for sleeve gastrectomy is safe and feasible.

Authors:  Tomás Jakob; Patricio Cal; Luciano Deluca; Ezequiel Fernández
Journal:  Surg Endosc       Date:  2016-05-03       Impact factor: 4.584

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.