Literature DB >> 26091681

Investigation of Air Quality Problems in an Indoor Swimming Pool: A Case Study.

Benoit Lévesque1, Lorraine Vézina2, Denis Gauvin3, Patrice Leroux4.   

Abstract

INTRODUCTION: Trichloramine (NCl3) is the contaminant suspected the most to cause irritative respiratory symptoms among swimmers and swimming pool workers. Following complaints by employees working in an indoor swimming pool, this study set out to identify the determinants of NCl3 air concentrations in that particular swimming pool.
METHODS: To document NCl3 air levels, air samples (n = 26) were collected once or twice a day for 3 h, at least 3 days per week, between October and December 2011. Water samples were taken three times during air sampling to verify free chlorine, chloramines, alkalinity, conductivity, pH, water temperature, and turbidity. Water changes were also recorded, along with the number of bathers. Ventilation (outdoor air flow) was modified to verify the influence of this important variable. Data were evaluated by analysis of variance.
RESULTS: Mean NCl3 air concentration was 0.38 mg m(-3). The best model explaining variations of NCl3 air levels (r2 = 0.83) included sampling period (P = 0.002, NCl3 was higher in the evening versus the morning), water changes (P = 0.02, NCl3 was lower with water changes between 60 and 90 min day(-1) versus <60 min day(-1)), and ventilation (P = 0.0002, NCl3 was lower with ≥2 air changes per hour (ACH) versus <1 ACH). DISCUSSION AND
CONCLUSION: Although based on only 26 air samples, our results indicate that ventilation is an important determinant of NCl3 air concentration in swimming pool air. There is limited information available on the air quality of indoor swimming pools and the relationship with ventilation. Efforts are needed to document the situation and to develop state-of-the-art facilities for ventilation of indoor swimming pools.
© The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

Entities:  

Keywords:  NCl3; air quality; chloramines; chlorine; disinfection by-products; swimmer; swimming pool; swimming pool worker; trichloramine; ventilation

Mesh:

Substances:

Year:  2015        PMID: 26091681     DOI: 10.1093/annhyg/mev038

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  2 in total

1.  A comprehensive air quality investigation at an aquatic centre: Indoor/outdoor comparisons.

Authors:  Evangelos I Tolis; Giorgos Panaras; John G Bartzis
Journal:  Environ Sci Pollut Res Int       Date:  2018-04-02       Impact factor: 4.223

2.  Early life swimming pool exposure and asthma onset in children - a case-control study.

Authors:  Martin Andersson; Helena Backman; Gunnar Nordberg; Annika Hagenbjörk; Linnea Hedman; Kåre Eriksson; Bertil Forsberg; Eva Rönmark
Journal:  Environ Health       Date:  2018-04-11       Impact factor: 5.984