Literature DB >> 26090047

Extravasation of contrast medium during CT examination: an observational case-control study.

Zayneb Alami1, Siham Nasri2, Samir Ahid3, Hanane Hadj Kacem2.   

Abstract

INTRODUCTION: Extravasation is an adverse reaction to intravenous injection of contrast medium (CM) during CT examination. The objectives of this study are to determine the frequency, management and outcomes of extravasations and to assess risk factors for extravasation.
METHODS: Every incident of extravasation which occurred between March 2012 and March 31, 2013 was recorded in an extravasation form. Ethics Committee approval was obtained and the patients gave their consent to participate in the study. Data collected in the form included patients' age, sex, comorbidities, symptoms, CM used, injection mode, site and rate, extravasated volume, location of extravasation, severity of injury, treatment and patient outcome. Each case was matched with 4 controls of the same age ± 5 years and the same gender when possible.
RESULTS: Extravasation occurred in 18 (7 women, 11 men) out of 2,000 injections of CM (0.9%) with a median age of 53 (10-78) years. Automated injection was performed in all cases with a mean rate of 1.7 ml/s. Large extravasated volumes (≥50 ml) were more observed in patients undergoing CT angiography (28.6% vs. 6.6%, although not significant P=0.112). Multivariate analysis revealed a significant association between patients with cardiac diseases and extravasation (OR: 7.3, 95% CI (1.09-49.05), P=0.04) whereas the injection rate is a protective factor from extravasation (P=0.002).
CONCLUSION: Extravasation of CM results in mild to moderate adverse effects in all cases. Our study suggests that patients with cardiac disease are more predisposed to contrast extravasation than others. Further and larger studies are needed to confirm this trend.

Entities:  

Keywords:  Extravasation; computed tomography (CT); contrast media/medium; risk factors

Mesh:

Substances:

Year:  2015        PMID: 26090047      PMCID: PMC4450038          DOI: 10.11604/pamj.2015.20.89.3276

Source DB:  PubMed          Journal:  Pan Afr Med J


Introduction

Contrast media (CM) are widely used in in computed tomography (CT) examination. CM may lead to various adverse reactions that may occur immediately (in the hour following the injection) or later (up to a week after the injection). The possible adverse reactions are an extravasation of CM, allergic, cardiovascular or renal reactions [1]. Extravasation, i.e. the flow of CM out of the vein into which it was injected, is a well-recognized adverse reaction to intravenous injection of CM in CT units. The main mechanism involved in extravasation is excessive pressure in the injection line mainly occurring with a high osmolality level, above 1.025-1.420 mOsm/kg water. Extravasation may be the result of the cytotoxicity of CM, its ionic character or not with conflicting results reported in the literature, the presence of meglumine as the cation, the volume of extravasated CM and the mechanical compression caused by large-volumes and indwelling intravenous lines [2]. When extravasation occurs from indwelling intravenous lines, it is often due to the development of phlebitis in the vein that is canulated [3]. A higher risk of extravasation is reported not only with elderly patients and small children, but also with unconscious and debilitated patients who are unable to complain about pain. Extravasation injury seems to be more severe in patients with subcutaneous atrophy, arterial insufficiency (due to atherosclerosis, diabetes mellitus or connective tissue diseases), or impaired venous or lymphatic drainage. Cancer patients receiving radiotherapy and/or chemotherapy are also considered at high risk because of poor lymphatic drainage, fragile and small-caliber veins [2-5]. Fortunately, extravasation mostly results in minor signs: redness, swelling, localized erythema and pain. In few cases, extravasation is severe with skin blistering, tissue necrosis and rarely, a compartment syndrome [4, 5]. According to the literature, incidence of extravasation is ranging from 0.03% to 0.94% [6-15]. The aim of this study was to determine the frequency, management and outcome of extravasation of CM in our hospital and to assess the possible risk factors of extravasation by a case-control study.

Methods

Population and study design

During a one-year period, between March 2012 and March 31, 2013, data for each extravasation incident observed after CM injection were prospectively recorded in an extravasation form. The forms were completed by a radiology resident. Data obtained included patient sex, age, comorbidity, type of CM extravasated, injection site, intravenous catheter gauge, contrast material injection rate, estimated extravasated volume (EEV), patient symptoms, severity of injury and treatment. Severity of injury was determined by initial signs reported and evolution. The study has Ethics Committee approval and the patients gave their consent to participate in the study.

Inclusion criteria

Each patient who developed an extravasation incident during CT examination with CM injection during the study period was considered as a case. Each case was matched with 4 controls so as to achieve a statistical power of 80%. The controls were patients with no extravasation but were blindly selectionned with the following inclusion criteria's: same age ± 5 years and same gender when possible.

Contrast medium (CM)

CM used during this period in the CT unit: ioxitalamate (Telebrix® 35, Guerbet, France), Iopromide (Ultravist®, Bayer Schering Pharma AG Germany) and iobitridol (Xenetix®, Guerbet, France).

Injection technique

Injections were performed by nurses experienced in intravenous injection technique. In most cases, an automated injector (Nemoto) was used and whenever it failed, we used manual injection. The injection site usually used was the antecubital fossa. If that venous access was not established, we used the vein in the forearm or in the hand. Lower extremities are never used in our hospital. In adults, we usually use 22-(blue) or 20-(pink) gauge catheters, rarely 18-(green) gauge catheters whereas in children, the 24-(yellow) gauge catheter is preferred. In hospitalized patients with indwelling intravenous catheters, patency is checked with a saline injection before starting the CM injection. Injection site is monitored in all patients from before initiation of CM injection until scan acquisition is complete. Adverse reactions to CM are well explained to patients, including instructions to report any pain or discomfort. Lacking plastic surgery in our hospital, a traumatology or vascular surgery consultation was provided for all extravasation injuries. Only clinical signs and symptoms were assessed to establish the severity of extravasation.

Statistical analysis

The statistical analysis was performed using the Statistical Package for Social Sciences (SPSS) v13.0. (Inc. Chicago,IL). The results were expressed as mean±standard deviation or in count and percentage. The comparison of quantitative and qualitative variables was carried out using respectively Student's t-test, Chi-square test and the exact Fisher test when the Chi-square was not applicable. A threshold of P<0.05 was considered significant. The variables collected from the study were tested for their potential relationship with extravasation. In a first step, each variable was assessed independently by univariate analysis. In a second one, the variables with P<0.05 were fed into a multiple regression model to assess the odds ratio.

Results

Between March 2012 and March 31, 2013, there were 7,461 CT examinations. Two thousands of them required intravenous injections of CM in our hospital (some patients underwent more than one CT examination). Extravasation occurred in 18 out of 2,000 injections (0.9%): 7 women and 11 men (Sex ratio M/F: 1,57) with a median age of 53 years (10-78 years). In three cases, extravasation occurred in a child (10yrs.) and 2 young adults (20, 26 yrs). Cardiovascular diseases (n=7) and neoplastic disorders (n=4) were the most common comorbidities in our patients. An automated injector was used in all patients with an injection rate between 1.5 and 2ml/s and a mean rate of 1.7 ml/s. Catheters used for contrast material injection were: 20 gauge (n=11), 22 gauge (n=4) and 18 gauge (n=2). The injection sites were located in the antecubital fossa in 10 cases, the dorsum of the hand (n=4) and wrist (n=3) and jugular vein in one case. Ionic and high-osmolality agents were used in only 4 cases. Five patients had an infusion for more than 24h. In 6 cases, the injections were upstream from a recent puncture site. In four patients of the 18 cases, acquisition was performed using a CT angiography protocol. Non-ionic extravasation volumes ranged from 10 to 100 ml in 15 patients (Figure 1). In three cases, the extravasated volume was not mentioned. Common symptoms reported were pain, swelling and edema (Figure 2, Table 1). Treatment consisted of suction of extravasated CM volume, application of ice packs, alcoholized bandage and elevation of the upper extremity. An additional treatment using painkillers based on the association of paracetamol and codeine was administered in 8 cases and local corticosteroid injection in the extravasation site in 4 cases. A traumatology or vascular surgery consultation was performed for 15 patients. None of the 18 cases was life threatening; all patients were asymptomatic after 48h, except for one patient who died of his comorbidity. We compared data from patients who experienced extravasation with data from a control sample of 72 patients who underwent IV injection of CM but had no complications of IV CM injection (Table 2).There is no difference between the two groups of age, gender or comorbidities except of cardiac diseases (33.3% vs. 8.3% in the control group, P=0.02). Automated injector was used in all patients. Ionic and high osmolality agents were more used in patients with extravasation than in the control group (P=0.001). No difference statistically significant in the injection site was observed between the two groups whereas the injection rates of CM were different (1.78 vs 1.93 ml/sec in the control group, Table 3 show that cardiac diseases increase the risks for 7.3 fold (95% CI (1.09-49.05) which is a statistically significant increase (P = 0.04) whereas the injection rate is a protective factor from extravasation (P=0.002).
Figure 1

Axial contrast-enhanced chest CT scan demonstrates extravasation of non- ionic CM into the right subcutaneous cervical region

Figure 2

Moderate extravasation injury in an adult patient demonstrates swelling and ecchymosis in the antecubital fossa

Table 1

Description of extravasation injuries observed in patients

No.Age (y)SexComorbiditiesType of CMCT AngiographyEEV (ml)Location of ExtravasationSymptoms
175MHypertensionNIYes100AFBlister, swelling, pain
278FMyocardial ischemiaNIYes90AFPain, edema, ecchymosis
375MHypertensionNIYes90JCervical swelling
447FNoneNINo80AFPain, swelling,ecchymosis
539FDyslipidemia, Breast fibroadenomaNINo76AFSwelling
648MAsthmaNINo50AFPain, edema, redness
755FNeoplastic disorderNINo40WSwelling
820FMyocardial ischemiaINo30AFPain, swelling, edema in biceps, hyperchromic skin lesions
972MNoneINo30AFPain, edema, redness
1010MPyschomotor retardationNINo21AFPain, swelling
1146FBreast cancerNINo20WPain, edema
1252MNoneNINo10WPain,edema, redness
1354MNoneNINo10AFPain, edema
1426MBrain cancerNINo10DPain, swelling
1566MStomach cancerINo*DPain, edema, inflammation
1661MDiabetes mellitus, hypertensionNINo<30DPain, edema
1742FValve replacement, Lymph node tuberculosisINo*DPain, redness, edema
1866MRhythm disorder, vasculitisNIYes*AFPain, redness

Not available

EEV: Estimated extravasated volume

I: ionic, NI: non-ionic, AF: antecubital fossa, J: jugular vein, W: wrist, D: dorsum of hand

Table 2

Characteristics of the population

CharacteristicsExtravasation n=18Controls n=72 P-value
Age (years) 51.8 ± 19.451.3 ± 19.3 0.92
Sex: Male 11 (61.1%)37 (51.4%) 0.46
Comorbidities
Cardiac disease 6 (33.3%)7 (9.7%) 0.02
Diabetes mellitus 1 (5.6%)3 (4.2%) 0.60
Asthma 1 (5.6%)2 (2.8%) 0.49
Neoplastic disease 4 (22.2%)30 (41.7%) 0.13
Contrast medium Ionic High Osmolality
4 (22%)- 0.001
4 (25%)12 (75%) 0.001
CT Angiography 3 (17.6%)4 (7.8%) 0.35
Injection rate (ml/s) 1.78 ± 0.171.93 ± 0.14 < 0.001
Injection site
Antecubital fossa Other[*] 8 (44.4%)10 (55.6%)32 (45.7%)38 (54.3%) 0.92
Intravenous catheter Gauge
16 Gauge 1 (5.6%)1 (1.4%) 0.365
18 Gauge 2 (11.1%)24 (33.8%) 0.059
20 Gauge 11 (61.1%)1 (1.4%) < 0.001
22 Gauge 4 (22.2%)45 (63.4%) 0.003
Injection upstream from a recent puncture site 6 (40%)9 (34.6%) 0.73
Infusion > 24h 5 (38.5%)7 (36.8%) 1

Dorsum of hand, wrist, jugular vein

Table 3

Risk factors for extravasation analyzed by univariate and multivariate analysis

Univariate analysisMultivariate analysis
VariablesOdds RatioCI 95%P-valueOdds RatioCI 95%P-value
Comorbidities1.49[0.52–4.27] 0.46
Cardiac disease 4.64[1.32–16.24] 0.016 7.31[1.09-49.05] 0.04
Diabetes mellitus 1.35[0.13–13.83] 0.80
Asthma 2.06[0.18-24.05] 0.56
Neoplastic disease 0.40[0.12–1.34] 0.14
CT Angiography 2.52[0.50–12.61] 0.26
Injection rate 0.002[0–0.70] 0.001 0[0-0.05] 0.002
Injection site 1.05[0.37–2.98] 0.92
Axial contrast-enhanced chest CT scan demonstrates extravasation of non- ionic CM into the right subcutaneous cervical region Moderate extravasation injury in an adult patient demonstrates swelling and ecchymosis in the antecubital fossa Description of extravasation injuries observed in patients Not available EEV: Estimated extravasated volume I: ionic, NI: non-ionic, AF: antecubital fossa, J: jugular vein, W: wrist, D: dorsum of hand Characteristics of the population Dorsum of hand, wrist, jugular vein Risk factors for extravasation analyzed by univariate and multivariate analysis

Discussion

This is the first study to estimate the rate of extravasation in our country. The overall extravasation rate in our institution (0.9%) is similar to the rates reported in the literature [6-15] (Table 4). However, the short period of our study (one year) and our sample size (2,000 in comparison to the largest study of Wang et al. [13] about intravenous injections) are important limitations of our study. In our study, extravasation has occurred when injections were applied on the dorsum of hand and the wrist (55.6% vs.54.3% in the control group) but also when injection was performed in the antecubital fossa with no difference between the two groups (44.4% vs.45.7% in the control group; P=0.92). This result is in contrast with other results, comparing 51 patients with extravasation with 100 patients who did not, reporting a higher percentage of extravasation in patients that have been injected outside the antecubital fossa (39% vs.24%) [16].This may be due to the fact that intravenous access in the antecubital fossa was difficult in our patients, as it was the case in the study of Wang et al. [13]. Sixty one percent (61.1%) of patients who had extravasation were injected through a 20-gauge catheter with a statistically significant difference with the control group (1.4%, P <0.001), even in respect of the catheter gauge recommendations. In the control group, most patients were injected through a 22-gauge catheter (63.4% vs. 22.2%; P=0.003). This finding doesn't seem to be in line with the results of Wienbeck et al. [15] where 4,457 patients were prospectively studied. We acknowledge that the sample size is a great limitation of our study.
Table 4

Rate of CM extravasation in published series

Authors [Ref]Year PublishedSample sizeType of populationType of CMNo of extravasationsRate (%)
Cohan et al [6] 199014,000Adult and childrenNon-ionic50.03
Miles et al [7] 19905,280Adult and children over 12y.Ionic, Non-ionic60.10
Sistrom et al [8] 199120,950Adult and childrenNon-ionic280.13
Cohan et al [9] 199722,254Adult and childrenIonic and Non-ionic510.23
Federle et al [10] 19985,106AdultIonic, Non-ionic480.94
Jacobs et al [11] 19986,660Adult and childrenIonic, Non- ionic400.60
Cochran et al [12] 200266,029Adult and childrenNon-ionic2250.34
Wang et al [13] 200769,657Adult and childrenNon-ionic4750.70
Callahan et al [14] 200912,494ChildrenNon-ionic570.46
Wienbeck et al [15] 20104,457AdultNon-ionic521.2
Total 226,887 950 0.42
Rate of CM extravasation in published series The extravasated volume of CM observed in our study ranged from 10 to 100ml. The largest study of Wang et al. [13] has reported an EEV varying from less than 10ml to 150ml. Large volumes of extravasation (90 and 100ml) were noted in patients who received a dynamic bolus CT injection located in the antecubital fossa and in the jugular in one case. In fact, dynamic bolus CT induces large volumes of CM [4]. A large volume extravasation may be also observed when extravasation is deep and/or when the patient remains asymptomatic [2]. The smallest volume (10ml) was observed when the injection was performed in the wrist or dorsum of the hand. Probably, the small surface areas of these portions of the limb limit the diffusion and the extravasation of CM. Large volumes (EEV ≥ 50ml) were observed in patients undergoing CT angiography (28.6% vs. 6.6%). However, this difference was not statistically significant (P=0.112). This can be explained by only 7 cases of CT angiography, probably not sufficient enough to prove this relationship. Because automated injector was used in all patients, we couldn't analyze its influence on extravasation. However, it is recognized that automated power injectors increase the flow of mechanical CM administration. The risk is higher with a “bolus-tracking” technique used in CT angiography [6]. In this study, CT angiography was more used in patients who had extravasation than in the control group (17.6% vs. 7.8%) but the difference was not statistically significant (P=0.35). This can be also explained by the few cases of CT angiography. As injection rate was always between 1.5 and 2ml/s in all patients, we could not analyze the influence of injection flow rate and extravasation. In the current study, there was no severe extravasation. Only mild to moderate extravasations of CM were recorded. This might be explained by the low flow rate applied and by our sample size that is too small to evaluate the rates of different severities of injuries. Extravasation was treated by suction of extravasated CM volume, application of ice packs, alcoholized bandage, elevation of the upper extremity and administration of painkillers and local corticosteroid injections. According to current guidelines [2, 4], there is no experimental evidence or consensus for the treatments used but conservative management is often sufficient without reconstructive surgery [6]. Administration of painkillers or local corticosteroid injection in most cases of our patients was not justified. Thus, management of extravasation in our institution must be reviewed and changed. We had written a form explaining the strategy of extravasation management. The form was presented to all staff of the Department of Radiology.

Conclusion

A low Injection rate is a protective factor from extravasation. However, it is not the only one. Our study suggests that patients with cardiac disease are more predisposed to contrast extravasation than others. This is in accordance with the fact that cardiovascular diseases enhance vascular fragility. To our knowledge, none of the published studies analyzed the influence of comorbidities of patients. Further and larger studies are needed to confirm this trend.
  14 in total

1.  Treatment of iodinated contrast material extravasation with hyaluronidase.

Authors:  Sachiko T Cochran; Karen Bomyea; Melissa Kahn
Journal:  Acad Radiol       Date:  2002-08       Impact factor: 3.173

Review 2.  Extravasation of radiographic contrast media: prevention, diagnosis, and treatment.

Authors:  Massimo Tonolini; Alessandro Campari; Roberto Bianco
Journal:  Curr Probl Diagn Radiol       Date:  2012 Mar-Apr

Review 3.  [Iatrogenic complications from contrast materials].

Authors:  O Clément
Journal:  J Radiol       Date:  2005-05

4.  Contrast media reactions and extravasation: relationship to intravenous injection rates.

Authors:  J E Jacobs; B A Birnbaum; C P Langlotz
Journal:  Radiology       Date:  1998-11       Impact factor: 11.105

5.  Safe use of an intravenous power injector for CT: experience and protocol.

Authors:  S G Miles; J F Rasmussen; T Litwiller; A Osik
Journal:  Radiology       Date:  1990-07       Impact factor: 11.105

Review 6.  Contrast medium extravasation injury: guidelines for prevention and management.

Authors:  Marie-France Bellin; Jarl A Jakobsen; Isabelle Tomassin; Henrik S Thomsen; Sameh K Morcos; H S Thomsen; S K Morcos; T Almén; P Aspelin; M F Bellin; W Clauss; H Flaten; N Grenier; J-M Ideé; J A Jakobsen; G P Krestin; F Stacul; J A W Webb
Journal:  Eur Radiol       Date:  2002-09-06       Impact factor: 5.315

7.  Prospective study of access site complications of automated contrast injection with peripheral venous access in MDCT.

Authors:  Susanne Wienbeck; Roman Fischbach; Stephan P Kloska; Peter Seidensticker; Noriaki Osada; Walter Heindel; Kai U Juergens
Journal:  AJR Am J Roentgenol       Date:  2010-10       Impact factor: 3.959

8.  Extravasation of nonionic radiologic contrast media: efficacy of conservative treatment.

Authors:  R H Cohan; N R Dunnick; R A Leder; M E Baker
Journal:  Radiology       Date:  1990-07       Impact factor: 11.105

9.  Frequency, management, and outcome of extravasation of nonionic iodinated contrast medium in 69,657 intravenous injections.

Authors:  Carolyn L Wang; Richard H Cohan; James H Ellis; Saroja Adusumilli; N Reed Dunnick
Journal:  Radiology       Date:  2007-04       Impact factor: 11.105

10.  Extravasation of iopamidol and iohexol during contrast-enhanced CT: report of 28 cases.

Authors:  C L Sistrom; S B Gay; L Peffley
Journal:  Radiology       Date:  1991-09       Impact factor: 11.105

View more
  1 in total

1.  Hand compartment syndrome secondary to contrast media extravasation: A case report.

Authors:  Badara Diop; Guillaume Tcheutchoua Soh; Armel Franck Tene Nde; Ndiamé Sarr; Abdou Yacine Ndoye; Jean Claude Sane
Journal:  Int J Surg Case Rep       Date:  2022-09-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.