Literature DB >> 26088780

Aptamer-functionalized nanoporous gold film for high-performance direct electrochemical detection of bisphenol A in human serum.

Ye Zhu1, Chuqing Zhou2, Xupeng Yan2, Yan Yan2, Qiang Wang3.   

Abstract

In the present work, a highly sensitive and selective biosensor based on aptamer-functionalized nanoporous gold film (NPGF) was successfully developed for direct electrochemical detection of bisphenol A (BPA). NPGF was prepared by dealloying Ag from Au/Ag alloy leaf in concentrated nitric acid. The obtained NPGF was attached onto glassy carbon electrode and then was functionalized with BPA-specific aptamer via the formation of Au-S bond. The fabrication of the sensor was characterized by scanning electron microscopy and X-ray photoelectron spectroscopy. NPGF exhibited excellent electrocatalytic activity towards the redox reaction of BPA, which ensured high sensitivity of the sensor. The aptamer-captured BPA showed a pair of redox peaks around 0.35/0.28 V (vs. Ag/AgCl). The experimental parameters in terms of aptamer concentration, reaction time, pH, and temperature were optimized. The calibration plot showed a linear range from 0.1 nM to 100 nM BPA with a remarkable detection limit of 0.056±0.004 nM BPA. Particularly, the successful application of the developed sensor for the detection of BPA in human serum samples suggests its promising potential for clinical diagnosis.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamer sensor; Bisphenol A; Direct electrochemical detection; Electrocatalysis; Nanoporous gold

Mesh:

Substances:

Year:  2015        PMID: 26088780     DOI: 10.1016/j.aca.2015.05.002

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  8 in total

1.  Minimum Bactericidal Concentration of Ciprofloxacin to Pseudomonas aeruginosa Determined Rapidly Based on Pyocyanin Secretion.

Authors:  Yi Liu; John H Moore; Glynis L Kolling; John S McGrath; Jason A Papin; Nathan S Swami
Journal:  Sens Actuators B Chem       Date:  2020-03-04       Impact factor: 7.460

2.  Voltammetric aptasensor for bisphenol A based on the use of a MWCNT/Fe3O4@gold nanocomposite.

Authors:  Mehdi Baghayeri; Reza Ansari; Marzieh Nodehi; Iman Razavipanah; Hojat Veisi
Journal:  Mikrochim Acta       Date:  2018-06-07       Impact factor: 5.833

3.  Biosensor design using an electroactive label-based aptamer to detect bisphenol A in serum samples.

Authors:  Maryam Nazari; Soheila Kashanian; Ronak Rafipour; Kobra Omidfar
Journal:  J Biosci       Date:  2019-09       Impact factor: 1.826

4.  Molecularly imprinted electrochemical aptasensor for the attomolar detection of bisphenol A.

Authors:  Ali A Ensafi; Maryam Amini; Behzad Rezaei
Journal:  Mikrochim Acta       Date:  2018-04-24       Impact factor: 5.833

5.  Aptamer-based Field-Effect Biosensor for Tenofovir Detection.

Authors:  N Aliakbarinodehi; P Jolly; N Bhalla; A Miodek; G De Micheli; P Estrela; S Carrara
Journal:  Sci Rep       Date:  2017-03-15       Impact factor: 4.379

Review 6.  Selection and Biosensor Application of Aptamers for Small Molecules.

Authors:  Franziska Pfeiffer; Günter Mayer
Journal:  Front Chem       Date:  2016-06-15       Impact factor: 5.221

Review 7.  Preparation, Modification, Characterization, and Biosensing Application of Nanoporous Gold Using Electrochemical Techniques.

Authors:  Jay K Bhattarai; Dharmendra Neupane; Bishal Nepal; Vasilii Mikhaylov; Alexei V Demchenko; Keith J Stine
Journal:  Nanomaterials (Basel)       Date:  2018-03-16       Impact factor: 5.076

Review 8.  Ensuring food safety using aptamer based assays: Electroanalytical approach.

Authors:  Hedieh Malekzad; Abolghasem Jouyban; Mohammad Hasanzadeh; Nasrin Shadjou; Miguel de la Guardia
Journal:  Trends Analyt Chem       Date:  2017-07-10       Impact factor: 12.296

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.