Literature DB >> 26087573

Effect of different prosthetic abutments on peri-implant soft tissue. A randomized controlled clinical trial.

Marco Ferrari, Maria Crysanti Cagidiaco, Franklin Garcia-Godoy, Cecilia Goracci, Francesco Cairo.   

Abstract

PURPOSE: This randomized clinical trial assessed the effect of three different prosthetic abutments (titanium, gold-hue titanium and zirconia) on peri-implant soft tissue 2 years after treatment in partially edentulous subjects.
METHODS: Baseline data concerning (1) thickness of the buccal peri-implant soft tissue, (2) soft tissue thickness above the bone crest, (3) depth/length of transmucosal pathway, and (4) periodontal biotype at adjacent teeth were collected. The final sample consisted of 47 subjects (21 males, 26 females) with a total of 97 implants. A two-level (patient, implant) statistical model was applied.
RESULTS: At the 2-year clinical observation, recession of the gingival margin was observed only at 13% of implants irrespective of the type of abutment. No significant correlation between periodontal biotype at adjacent teeth and peri-implant biotype was observed. Furthermore, none of the investigated variables at patient level (age, gender, implant type, periodontal biotype) or at implant level (keratinized tissue thickness, probing depth, soft tissue thickness) was identified as a significant predictor of recession. In conclusion, this study pointed out that (1) abutment type was not able to influence peri-implant variables after 2 years, and (2) caution should be used in considering periodontal biotype at patient level as a possible indicator of the future peri-implant biotype.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26087573

Source DB:  PubMed          Journal:  Am J Dent        ISSN: 0894-8275            Impact factor:   1.522


  3 in total

1.  Peri-implant soft tissue integration in humans - influence of materials: A study protocol for a randomised controlled trial and a pilot study results.

Authors:  Manon Borie; Geoffrey Lecloux; Dieter Bosshardt; Alejandro Barrantes; Håvard Jostein Haugen; France Lambert; Miljana Bacevic
Journal:  Contemp Clin Trials Commun       Date:  2020-08-15

Review 2.  Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis.

Authors:  Amr G ElHoussiney; He Zhang; Jinlin Song; Ping Ji; Lu Wang; Sheng Yang
Journal:  Clin Cosmet Investig Dent       Date:  2018-02-26

3.  Influence of scaling procedures on the integrity of titanium nitride coated CAD/CAM abutments.

Authors:  Peter Gehrke; Emmanouil Spanos; Carsten Fischer; Helmut Storck; Florian Tebbel; Dirk Duddeck
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.