Literature DB >> 26086018

Effectiveness of in-office blood pressure measurement by eye care practitioners in early detection and management of hypertension.

Saud A AlAnazi1, Uchechukwu L Osuagwu2, Turki M AlMubrad1, Hany K Ahmed3, Kelechi C Ogbuehi4.   

Abstract

AIM: To investigate the number of hypertensive patients, the optometrist is able to identify by routinely taking blood pressure (BP) measurements for patients in "at-risk" groups, and to sample patients' opinions regarding in-office BP measurement. Many of the optometrists in Saudi Arabia practice in optical stores. These stores are wide spread, easily accessible and seldom need appointments. The expanding role of the optometrist as a primary health care provider (PHCP) and the increasing global prevalence of hypertension, highlight the need for an integrated approach towards detecting and monitoring hypertension.
METHODS: Automated BP measurements were made twice (during the same session) at five selected optometry practices using a validated BP monitor (Omron M6) to assess the number of patients with high BP (HBP) -in at-risk groups-visiting the eye clinic routinely. Prior to data collection, practitioners underwent a two-day training workshop by a cardiologist on hypertension and how to obtain accurate BP readings. A protocol for BP measurement was distributed and retained in all participating clinics. The general attitude towards cardiovascular health of 480 patients aged 37.2 (±12.4)y and their opinion towards in-office BP measurement was assessed using a self-administered questionnaire.
RESULTS: A response rate of 83.6% was obtained for the survey. Ninety-three of the 443 patients (21.0%) tested for BP in this study had HBP. Of these, (62 subjects) 66.7% were unaware of their HBP status. Thirty of the 105 subjects (28.6%) who had previously been diagnosed with HBP, still had HBP at the time of this study, and only 22 (73.3%) of these patients were on medication. Also, only 25% of the diagnosed hypertensive patients owned a BP monitor.
CONCLUSION: Taking BP measurements in optometry practices, we were able to identify one previously undiagnosed patient with HBP for every 8 adults tested. We also identified 30 of 105 previously diagnosed patients whose BP was poorly controlled, twenty-two of whom were on medication. The patients who participated in this study were positively disposed toward the routine measurement of BP by optometrists.

Entities:  

Keywords:  blood pressure; high blood pressure; hypertension; optometrist; public health

Year:  2015        PMID: 26086018      PMCID: PMC4458673          DOI: 10.3980/j.issn.2222-3959.2015.03.32

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  48 in total

Review 1.  The role of patient care teams in chronic disease management.

Authors:  E H Wagner
Journal:  BMJ       Date:  2000-02-26

2.  Quality improvement in chronic illness care: a collaborative approach.

Authors:  E H Wagner; R E Glasgow; C Davis; A E Bonomi; L Provost; D McCulloch; P Carver; C Sixta
Journal:  Jt Comm J Qual Improv       Date:  2001-02

3.  Global burden of hypertension: analysis of worldwide data.

Authors:  Patricia M Kearney; Megan Whelton; Kristi Reynolds; Paul Muntner; Paul K Whelton; Jiang He
Journal:  Lancet       Date:  2005 Jan 15-21       Impact factor: 79.321

Review 4.  Ocular signs of systemic hypertension: a review.

Authors:  P G Hurcomb; J S Wolffsohn; G A Napper
Journal:  Ophthalmic Physiol Opt       Date:  2001-11       Impact factor: 3.117

5.  Assessing the role of optometrists in the control of systemic hypertension in Saudi Arabia.

Authors:  Uchechukwu L Osuagwu; Kelechi C Ogbuehi; Turki M Almubrad
Journal:  J Am Soc Hypertens       Date:  2013-04-09

6.  Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure.

Authors:  Aram V Chobanian; George L Bakris; Henry R Black; William C Cushman; Lee A Green; Joseph L Izzo; Daniel W Jones; Barry J Materson; Suzanne Oparil; Jackson T Wright; Edward J Roccella
Journal:  Hypertension       Date:  2003-12-01       Impact factor: 10.190

7.  Is measurement of blood pressure worthwhile in the diabetic eye clinic?

Authors:  S Al-Husainy; J Farmer; J M Gibson; P M Dodson
Journal:  Eye (Lond)       Date:  2005-03       Impact factor: 3.775

8.  A survey of the graduates of the University of Alabama School of Optometry. Screening for hypertension.

Authors:  R N Kleinstein; L Maxwell; J B Wayne; E D Charles
Journal:  J Am Optom Assoc       Date:  1982-05

Review 9.  Hypertension and the eye: applications of the Sixth Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure.

Authors:  E C Marshall; V E Malinovsky
Journal:  J Am Optom Assoc       Date:  1998-05

Review 10.  Prevalence of arterial hypertension among Brazilian adolescents: systematic review and meta-analysis.

Authors:  Erika Silva Magliano; Luciane Gaspar Guedes; Evandro Silva Freire Coutinho; Katia Vergetti Bloch
Journal:  BMC Public Health       Date:  2013-09-11       Impact factor: 3.295

View more
  1 in total

1.  The application of arterio-venous ratio (AVR) cut-off values in clinic to stratify cardiovascular risk in patients.

Authors:  Christian French; Robert Peter Cubbidge; Rebekka Heitmar
Journal:  Ophthalmic Physiol Opt       Date:  2022-03-07       Impact factor: 3.992

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.