Literature DB >> 26085116

Stainless steel surface biofunctionalization with PMMA-bioglass coatings: compositional, electrochemical corrosion studies and microbiological assay.

L Floroian1, C Samoila, M Badea, D Munteanu, C Ristoscu, F Sima, I Negut, M C Chifiriuc, I N Mihailescu.   

Abstract

A solution is proposed to surpass the inconvenience caused by the corrosion of stainless steel implants in human body fluids by protection with thin films of bioactive glasses or with composite polymer-bioactive glass nanostructures. Our option was to apply thin film deposition by matrix-assisted pulsed laser evaporation (MAPLE) which, to the difference to other laser or plasma techniques insures the protection of a more delicate material (a polymer in our case) against degradation or irreversible damage. The coatings composition, modification and corrosion resistance were investigated by FTIR and electrochemical techniques, under conditions which simulate their biological interaction with the human body. Mechanical testing demonstrates the adhesion, durability and resistance to fracture of the coatings. The coatings biocompatibility was assessed by in vitro studies and by flow cytometry. Our results support the unrestricted usage of coated stainless steel as a cheap alternative for human implants manufacture. They will be more accessible for lower prices in comparison with the majority present day fabrication of implants using Ti or Ti alloys.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26085116     DOI: 10.1007/s10856-015-5527-y

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  7 in total

1.  Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials.

Authors:  M Aziz-Kerrzo; K G Conroy; A M Fenelon; S T Farrell; C B Breslin
Journal:  Biomaterials       Date:  2001-06       Impact factor: 12.479

Review 2.  Laser deposition of polymer and biomaterial films.

Authors:  D B Chrisey; A Piqué; R A McGill; J S Horwitz; B R Ringeisen; D M Bubb; P K Wu
Journal:  Chem Rev       Date:  2003-02       Impact factor: 60.622

3.  Anionic polymers and 10 nm Fe₃O₄@UA wound dressings support human foetal stem cells normal development and exhibit great antimicrobial properties.

Authors:  Alexandru Mihai Grumezescu; Alina Maria Holban; Ecaterina Andronescu; George Dan Mogoşanu; Bogdan Stefan Vasile; Mariana Carmen Chifiriuc; Veronica Lazar; Eugen Andrei; Andrei Constantinescu; Horia Maniu
Journal:  Int J Pharm       Date:  2013-08-29       Impact factor: 5.875

4.  The effects on bone cells of metal ions released from orthopaedic implants. A review.

Authors:  Valerio Sansone; Davide Pagani; Marco Melato
Journal:  Clin Cases Miner Bone Metab       Date:  2013-01

5.  Electrochemical characterization of cast titanium alloys.

Authors:  Zhuo Cai; Ty Shafer; Ikuya Watanabe; Martha E Nunn; Toru Okabe
Journal:  Biomaterials       Date:  2003-01       Impact factor: 12.479

6.  Solutions able to reproduce in vivo surface-structure changes in bioactive glass-ceramic A-W.

Authors:  T Kokubo; H Kushitani; S Sakka; T Kitsugi; T Yamamuro
Journal:  J Biomed Mater Res       Date:  1990-06

7.  In vitro corrosion study by EIS of a nickel-free stainless steel for orthopaedic applications.

Authors:  G Rondelli; P Torricelli; M Fini; R Giardino
Journal:  Biomaterials       Date:  2005-03       Impact factor: 12.479

  7 in total
  6 in total

Review 1.  Polymeric Coatings and Antimicrobial Peptides as Efficient Systems for Treating Implantable Medical Devices Associated-Infections.

Authors:  Irina Negut; Bogdan Bita; Andreea Groza
Journal:  Polymers (Basel)       Date:  2022-04-15       Impact factor: 4.967

2.  Implant Surfaces Containing Bioglasses and Ciprofloxacin as Platforms for Bone Repair and Improved Resistance to Microbial Colonization.

Authors:  Irina Negut; Carmen Ristoscu; Tatiana Tozar; Mihaela Dinu; Anca Constantina Parau; Valentina Grumezescu; Claudiu Hapenciuc; Marcela Popa; Miruna Silvia Stan; Luminita Marutescu; Ion N Mihailescu; Mariana Carmen Chifiriuc
Journal:  Pharmaceutics       Date:  2022-05-30       Impact factor: 6.525

3.  Improved antifouling properties and selective biofunctionalization of stainless steel by employing heterobifunctional silane-polyethylene glycol overlayers and avidin-biotin technology.

Authors:  Ville Hynninen; Leena Vuori; Markku Hannula; Kosti Tapio; Kimmo Lahtonen; Tommi Isoniemi; Elina Lehtonen; Mika Hirsimäki; J Jussi Toppari; Mika Valden; Vesa P Hytönen
Journal:  Sci Rep       Date:  2016-07-06       Impact factor: 4.379

4.  Functionalized Antimicrobial Composite Thin Films Printing for Stainless Steel Implant Coatings.

Authors:  Laura Floroian; Carmen Ristoscu; Natalia Mihailescu; Irina Negut; Mihaela Badea; Doru Ursutiu; Mariana Carmen Chifiriuc; Iuliana Urzica; Hussien Mohammed Dyia; Coralia Bleotu; Ion N Mihailescu
Journal:  Molecules       Date:  2016-06-09       Impact factor: 4.411

5.  Functional Bioglass-Biopolymer Double Nanostructure for Natural Antimicrobial Drug Extracts Delivery.

Authors:  Irina Negut; Laura Floroian; Carmen Ristoscu; Cristian N Mihailescu; Julia Claudia Mirza Rosca; Tatiana Tozar; Mihaela Badea; Valentina Grumezescu; Claudiu Hapenciuc; Ion N Mihailescu
Journal:  Nanomaterials (Basel)       Date:  2020-02-22       Impact factor: 5.076

6.  Biological safety of Electroacupuncture with STS316 needles.

Authors:  Kwang-Ho Choi; Sun Hee Yeon; Seong Jin Cho; O Sang Kwon; Sanghun Lee; Su Yeon Seo; Suk-Yun Kang; Yeonhee Ryu
Journal:  BMC Complement Altern Med       Date:  2019-10-28       Impact factor: 3.659

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.