Literature DB >> 26082516

Impact of freezing time and balloon size on the thermodynamics and isolation efficacy during pulmonary vein isolation using the second generation cryoballoon.

Mitsuru Takami1, H Immo Lehmann1, Juna Misiri1, Kay D Parker1, Ray I Sarmiento1, Susan B Johnson1, Douglas L Packer2.   

Abstract

BACKGROUND: The differences in ablation characteristics of freezing time and balloon size using second generation cryoballoon are still unknown. METHODS AND
RESULTS: Twenty-six dogs underwent pulmonary vein (PV) isolation. Balloon and tissue temperatures (left atrial-PV junction, phrenic nerve, and internal esophagus) were monitored. The ablation duration was randomized to either 3 or 4 minutes, which did not show significant differences in temperature profiles, PV isolation success rate, complications, or histological changes. Twenty dogs underwent cryoablation using 28-mm cryoballoon, 6 dogs were done using the 23-mm cryoballoon. Positioning of the 23-mm cryoballoon was more distal in the PV, which resulted in better PV occlusion. Temperature profiles showed lower temperatures in the 23-mm cryoballoon than in the 28-mm cryoballoon (inner balloon, median [range]: -51.5 [-66.0 to -31.0] versus -43.0 [-64.0 to -26.0]°C, P<0.001; balloon surface: -43.0 [-60.0 to -15.8] versus -6.5 [-46.2 to 28.9]°C, P<0.001; left atrial-PV junction: -6.7 [-20.0 to 21.4] versus 15.8 [-14.4 to 35.1]°C, P<0.001), and trended toward a higher PV isolation success rate in the 23-mm cryoballoon. Histologically, deeper extensions of ablative lesions into the PV were seen with 23-mm cryoballoon, and larger ablative lesions were seen in the left atrial antrum using 28-mm cryoballoon.
CONCLUSIONS: The efficacy of 3-minute ablation was not significantly different from 4-minute ablation in dogs. The 23-mm cryoballoon had a greater cooling effect than the 28-mm cryoballoon for small PVs, but showed narrower ablative lesions in the left atrial antrum.
© 2015 American Heart Association, Inc.

Entities:  

Keywords:  atrial fibrillation; cryoballoon; esophagus; freezing; pulmonary vein; thermodynamics

Mesh:

Year:  2015        PMID: 26082516     DOI: 10.1161/CIRCEP.115.002725

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  12 in total

1.  2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation.

Authors:  Hugh Calkins; Gerhard Hindricks; Riccardo Cappato; Young-Hoon Kim; Eduardo B Saad; Luis Aguinaga; Joseph G Akar; Vinay Badhwar; Josep Brugada; John Camm; Peng-Sheng Chen; Shih-Ann Chen; Mina K Chung; Jens Cosedis Nielsen; Anne B Curtis; D Wyn Davies; John D Day; André d'Avila; N M S Natasja de Groot; Luigi Di Biase; Mattias Duytschaever; James R Edgerton; Kenneth A Ellenbogen; Patrick T Ellinor; Sabine Ernst; Guilherme Fenelon; Edward P Gerstenfeld; David E Haines; Michel Haissaguerre; Robert H Helm; Elaine Hylek; Warren M Jackman; Jose Jalife; Jonathan M Kalman; Josef Kautzner; Hans Kottkamp; Karl Heinz Kuck; Koichiro Kumagai; Richard Lee; Thorsten Lewalter; Bruce D Lindsay; Laurent Macle; Moussa Mansour; Francis E Marchlinski; Gregory F Michaud; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Ken Okumura; Douglas Packer; Evgeny Pokushalov; Matthew R Reynolds; Prashanthan Sanders; Mauricio Scanavacca; Richard Schilling; Claudio Tondo; Hsuan-Ming Tsao; Atul Verma; David J Wilber; Teiichi Yamane
Journal:  Heart Rhythm       Date:  2017-05-12       Impact factor: 6.343

2.  2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Developed in partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC) and the European Cardiac Arrhythmia Society (ECAS); and in collaboration with the American College of Cardiology (ACC), American Heart Association (AHA), the Asia Pacific Heart Rhythm Society (APHRS), and the Society of Thoracic Surgeons (STS). Endorsed by the governing bodies of the American College of Cardiology Foundation, the American Heart Association, the European Cardiac Arrhythmia Society, the European Heart Rhythm Association, the Society of Thoracic Surgeons, the Asia Pacific Heart Rhythm Society, and the Heart Rhythm Society.

Authors:  Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; José Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber
Journal:  Heart Rhythm       Date:  2012-03-01       Impact factor: 6.343

Review 3.  2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation.

Authors:  Hugh Calkins; Gerhard Hindricks; Riccardo Cappato; Young-Hoon Kim; Eduardo B Saad; Luis Aguinaga; Joseph G Akar; Vinay Badhwar; Josep Brugada; John Camm; Peng-Sheng Chen; Shih-Ann Chen; Mina K Chung; Jens Cosedis Nielsen; Anne B Curtis; D Wyn Davies; John D Day; André d'Avila; N M S Natasja de Groot; Luigi Di Biase; Mattias Duytschaever; James R Edgerton; Kenneth A Ellenbogen; Patrick T Ellinor; Sabine Ernst; Guilherme Fenelon; Edward P Gerstenfeld; David E Haines; Michel Haissaguerre; Robert H Helm; Elaine Hylek; Warren M Jackman; Jose Jalife; Jonathan M Kalman; Josef Kautzner; Hans Kottkamp; Karl Heinz Kuck; Koichiro Kumagai; Richard Lee; Thorsten Lewalter; Bruce D Lindsay; Laurent Macle; Moussa Mansour; Francis E Marchlinski; Gregory F Michaud; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Ken Okumura; Douglas Packer; Evgeny Pokushalov; Matthew R Reynolds; Prashanthan Sanders; Mauricio Scanavacca; Richard Schilling; Claudio Tondo; Hsuan-Ming Tsao; Atul Verma; David J Wilber; Teiichi Yamane
Journal:  Europace       Date:  2018-01-01       Impact factor: 5.214

4.  Outcome of paroxysmal atrial fibrillation ablation with the cryoballoon using two different application times: the 4- versus 3-min protocol.

Authors:  Florian Straube; Uwe Dorwarth; Stefan Hartl; Benedikt Bunz; Michael Wankerl; Ullrich Ebersberger; Ellen Hoffmann
Journal:  J Interv Card Electrophysiol       Date:  2015-12-23       Impact factor: 1.900

Review 5.  [Practical guide for safe and efficient cryoballoon ablation for atrial fibrillation : Practical procedure, tips and tricks].

Authors:  Julian Chun; Tilman Maurer; Andreas Rillig; Stefano Bordignon; Leon Iden; Sonia Busch; Daniel Steven; Roland R Tilz; Dong-In Shin; Heidi Estner; Felix Bourier; David Duncker; Philipp Sommer; Nils-Christian Ewertsen; Henning Jansen; Victoria Johnson; Livio Bertagnolli; Till Althoff; Andreas Metzner
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2021-11-04

6.  Mechanistic Insights Into Durable Pulmonary Vein Isolation Achieved by Second-Generation Cryoballoon Ablation.

Authors:  Yasuo Okumura; Ichiro Watanabe; Kazuki Iso; Keiko Takahashi; Koichi Nagashima; Kazumasa Sonoda; Hiroaki Mano; Naoko Yamaguchi; Rikitake Kogawa; Ryuta Watanabe; Masaru Arai; Kimie Ohkubo; Sayaka Kurokawa; Toshiko Nakai; Atsushi Hirayama
Journal:  J Atr Fibrillation       Date:  2017-04-30

7.  Eccentric scar formation around a pulmonary vein after cryo-balloon ablation in a patient with atrial fibrillation: A case report.

Authors:  Kunihiko Kiuchi; Koji Fukuzawa; Akinori Matsumoto
Journal:  J Arrhythm       Date:  2016-02-23

8.  High-sensitive cardiac troponin T as a predictor of efficacy and safety after pulmonary vein isolation using focal radiofrequency, multielectrode radiofrequency and cryoballoon ablation catheter.

Authors:  Ivan Zeljkovic; Sven Knecht; Nikola Pavlovic; Umut Celikyrut; Florian Spies; Sarah Burri; Dominik Mannhart; Loris Peterhans; Tobias Reichlin; Beat Schaer; Stefan Osswald; Christian Sticherling; Michael Kuhne
Journal:  Open Heart       Date:  2019-04-20

Review 9.  Strategies to Improve the Outcome of Cryoballoon Ablation in the Treatment of Atrial Fibrillation.

Authors:  Ying Huang; Yuehan Wang; Chenyu Song
Journal:  Biomed Res Int       Date:  2020-04-06       Impact factor: 3.411

10.  Assessment of a novel cryoablation device for the endovascular treatment of cardiac tachyarrhythmias.

Authors:  John M Baust; Anthony Robilotto; Peter Guerra; Kristi K Snyder; Robert G Van Buskirk; Marc Dubuc; John G Baust
Journal:  SAGE Open Med       Date:  2018-05-04