Literature DB >> 26081230

[Comparative study of the tilt, decentration and higher-order aberrations (HOA) of single-piece and 3-piece tecnis aspheric intraocular lenses].

Fang Yu1, Pingjun Chang1, Jin Li1, Yongmou Zhou1, Yun'e Zhao2.   

Abstract

PURPOSE: To compare the tilt and decentration between a single-piece and a 3-piece aspheric intraocular lens (IOL), and the impact of these factors on the HOAs after phacoemulsification and IOL implanted in capsular bag.
METHODS: It is a prospective randomized clinical trial. According to the table of random number, 72 eyes of 49 patients were divided into 2 groups. One group received a 1-piece aspheric IOL (Tecnis ZCB00, AMO) and a 3-piece aspheric IOL (Tecnis ZA9003, AMO) in the other group. The tilt at 45°, 90°, 135° and180° and decentration of the IOL were obtained using Scheimphlug system (Pentacam,Oculus) and image-analysis 3 months after the surgery. The internal ocular HOA of the IOL were evaluated with iTrace examination. The tilt and decentration of the IOL and the variables of the internal ocular HOAs were compared by independent-samples t test. The effect of tilt and decentration on the HOAs was assessed by Pearson correlation analysis.
RESULTS: Patients age ranged from 50 to 80 years. The best corrected visual acuity (BCVA) of both group were all not less than 0.5. In 3-piece IOLs group, there was a significant positive correlation between the BCVA and the astigmatism (Z3) (r=0.504, P=0.003; r=0.637, P=0.000) and a significant negative correlation between the BCVA and the fourth-order astigmatism (Z13) of the 3-piece aspheric IOL group [(0.90±0.78)° and (0.98±0.73)°, respectively] were higher than those in 1-piece aspheric IOL group [(0.50±0.33)° and (0.69±0.41)°, respectively], the differences were statistically significant (t=2.899, P=0.005; t=2.120, P=0.038). At 5.0 mm pupil, the defocus (Z4), astigmatism (Z5), third-order coma (Z8), fourth-order astigmatism (Z11) and fourth-order spherical (Z12) in 3-piece aspheric IOLs group were higher than those in 1-piece aspheric IOL group, the difference were statistically significant (t=2.372, P=0.021; t=2.801, P=0.007; t=3.269, P=0.002; t=3.230, P=0.002; t=3.468, P=0.001). In 3-piece IOL group, a significant positive correlation was found between the mean tilt and the fourth-order astigmatism (Z13) at 3.0 mm and 5.0 mm pupil (r=0.396, P=0.023; r=0.378, P=0.030), and a significant negative correlation was also found between the decentration and the fourth-order astigmatism (Z13) with at 3.0 mm pupil (r=-0.441, P=0.010).
CONCLUSIONS: Both 1-piece and 3-piece IOL designs showed well stability in capsular bag, the former was slightly more stable with better visual quality. There was no significant correlation between the internal ocular HOA and the degrees of IOL tilt and decentration in the 1-piece aspheric IOL group. At different pupil diameters, a significant correlation was found between the decentration and tilt of IOL and fourth-order astigmatism Z (13) in the 3-piece IOL group.

Entities:  

Mesh:

Year:  2015        PMID: 26081230

Source DB:  PubMed          Journal:  Zhonghua Yan Ke Za Zhi        ISSN: 0412-4081


  3 in total

Review 1.  Tilt and decentration with various intraocular lenses: A narrative review.

Authors:  Xiao-Yong Chen; Yu-Chen Wang; Tian-Yao Zhao; Zi-Zhen Wang; Wei Wang
Journal:  World J Clin Cases       Date:  2022-04-26       Impact factor: 1.534

2.  The relationship between angle kappa and astigmatism after phacoemulsification with implanting of spherical and aspheric intraocular lens.

Authors:  Larysa Tutchenko; Sudi Patel; Mykhailo Skovron; Olha Horak; Oleksiy Voytsekhivskyy
Journal:  Indian J Ophthalmol       Date:  2021-12       Impact factor: 1.848

3.  [Combination of lens decentration and tilt in phakic and pseudophakic eyes-Optical simulation of defocus, astigmatism and coma].

Authors:  Achim Langenbucher; Pooria Omidi; Timo Eppig; Nóra Szentmáry; Rupert Menapace; Peter Hoffmann
Journal:  Ophthalmologe       Date:  2020-09-30       Impact factor: 1.059

  3 in total