| Literature DB >> 26078848 |
Shmuel Springer1, Yocheved Laufer2, Michal Elboim-Gabyzon2.
Abstract
BACKGROUND: Electro-physical agents (EPAs) are fundamental components in the management arsenal of physiotherapy. The objective of this study was to provide a comprehensive understanding of the factors affecting the decisions made by Physiotherapists (PTs) when choosing to apply EPAs as a treatment modality.Entities:
Keywords: Decision-making; Electro-physical agents; Physiotherapy
Year: 2015 PMID: 26078848 PMCID: PMC4466804 DOI: 10.1186/s13584-015-0015-x
Source DB: PubMed Journal: Isr J Health Policy Res ISSN: 2045-4015
Demographic characteristics of the study sample (n = 144)
|
|
|
|---|---|
| Age, years | 38.3 ± 9.4 |
| Gender | |
| Male | 72 (50.0) |
| Female | 71 (49.3) |
| Not indicated | 1 (0.7) |
| Degree | |
| Bachelors (entry level) | 144 (100) |
| Advanced masters in PT | 24 (16.7) |
| Masters in another area | 15 (10.4) |
| Professional seniority, years | 11.2 ± 9.9 |
| Area of practice | |
| Orthopedic and sports rehabilitation | 90 (62.5) |
| Neurologic rehabilitation | 29 (20.1) |
| Women’s health | 3 (2.1) |
| Child development | 3 (2.1) |
| Respiratory rehabilitation | 5 (3.5) |
| Geriatric rehabilitation | 10 (6.9) |
| Education | 4 (2.8) |
| Hours worked per week | |
| 0-10 hours | 13 (9.0) |
| 21-30 hours | 57 (39.6) |
| 31-40 hours | 41 (28.5) |
| >40 hours | 33 (22.9) |
| Postgraduate courses in EPAs | |
| Yes | 62 (43.1) |
| No | 81 (56.2) |
| Not indicated | 1 (0.7) |
EPAs- Electro-physical agents.
Availability and use of Electro-physical agents (EPA)
|
|
|
| ||||||
|---|---|---|---|---|---|---|---|---|
|
|
|
|
|
|
|
|
| |
| Biofeedback EMG | 36.0 (49) | 53.7 (73) | 10.3 (14) | 5.3 (5) | 5.3 (5) | 8.5 (8) | 12.8 (12) | 68.1 (64) |
| Cold packs/ice | 85.8 (121) | 9.9 (14) | 4.3 (6) | 20.2 (26) | 20.9 (27) | 14.7 (19) | 19.4 (25) | 24.8 (32) |
| FES | 35.3 (49) | 48.9 (68) | 15.8 (22) | 16.3 (15) | 6.5 (6) | 8.7 (8) | 12.0 (11) | 56.5 (52) |
| Heat packs | 93.0 (133) | 6.3 (9) | 0.7 (1) | 51.1 (68) | 24.8 (33) | 10.5 (14) | 6.1 (8) | 7.5 (10) |
| IFC | 85.1 (120) | 13.5 (19) | 1.4 (2) | 48.0 (59) | 15.4 (19) | 6.5 (8) | 10.6 (13) | 19.5 (24) |
| Infrared | 6.5 (9) | 86.2 (119) | 7.3 (10) | 5.6 (4) | 1.4 (1) | 0 (0) | 12.7 (9) | 80.3 (57) |
| Laser | 16.6 (23) | 74.8 (104) | 8.6 (12) | 6.2 (5) | 3.7 (3) | 2.5 (2) | 11.3 (9) | 76.3 (61) |
| NMES | 80.0 (112) | 14.3 (20) | 5.7 (8) | 21.8 (27) | 15.3 (19) | 18.5 (23) | 13.7 (17) | 30.7 (38) |
| Shockwave | 15.4 (21) | 26.5 (104) | 8.1 (11) | 10.8 (8) | 8.1 (6) | 2.7 (2) | 9.5 (7) | 68.9 (51) |
| Shortwave diathermy | 43.6 (61) | 52.1 (73) | 4.3 (6) | 21.9 (23) | 11.5 (12) | 1.9 (2) | 17.1 (18) | 47.6 (50) |
| TENS | 96.5 (138) | 2.8 (4) | 0.7 (1) | 47.8 (66) | 21.7 (30) | 11.6 (16) | 7.3 (10) | 11.6 (16) |
| Ultrasound | 92.3 (132) | 5.6 (8) | 2.1 (3) | 38.0 (52) | 21.9 (30) | 4.4 (6) | 16.0 (22) | 19.7 (27) |
| Whirlpool bath | 68.6 (96) | 28.6 (40) | 2.8 (4) | 26.1 (30) | 19.1 (22) | 9.6 (11) | 13.0 (15) | 32.2 (37) |
EPAs- Electro-physical agents, TENS- Transcutaneous electrical stimulation, IFC- Interferential current, NMES- Neuromuscular electrical stimulation, FES- Functional electrical stimulation.
Factors that influence the decision to use EPAs
|
|
|
| ||||
|---|---|---|---|---|---|---|
|
|
|
|
|
| ||
|
| 2 | |||||
| Entry level (undergraduate) studies & training background | 3.6 (5) | 8.6 (12) | 28.8 (40) | 44.6 (62) | 14.4 (20) | |
| Continuing education studies & training | 13.2 (18) | 11.1 (15) | 22.8 (31) | 39.7 (54) | 13.2 (18) | |
| Previous clinical experience with EPSs | 1.4 (2) | 2.9 (4) | 15.1 (21) | 49.7 (69) | 30.9 (43) | |
| Demonstration and exposure to new equipment by medical marketers | 21.6 (30) | 27.3 (38) | 36 (50) | 12.9 (18) | 2.2 (3) | |
|
| 5 (7) | 8.5 (12) | 31.9 (45) | 39.7 (56) | 14.9 (21) | 2 |
|
| 3 | |||||
| “Technophobia” | 61 (86) | 17 (24) | 14.9 (21) | 5 (7) | 2.1 (3) | |
| Fear of adverse events | 30.5 (43) | 35.5 (50) | 18.4 (26) | 12.8 (18) | 2.8 (4) | |
|
| 4.3 (6) | 5 (7) | 25.7 (36) | 35 (49) | 30 (42) | 1 |
|
| 2 | |||||
| Time and ease of application | 12.8 (18 ) | 18.4 (26) | 32.6 (46) | 29.8 (42) | 6.4 (9) | |
| Degree of self-confidence operating the device | 9.2 (13) | 10.6 (15) | 17.7 (25) | 44.7 (63) | 17.8 (25) | |
| Busy and tight schedule at workplace | 14.2 (20) | 20.6 (29) | 32.6 (46) | 22 (31) | 10.6 (15) | |
|
| 3 | |||||
| Patient preference/request | 5.7 (8) | 23.6 (33) | 32.9 (46) | 29.3 (41) | 8.5 (12) | |
| Instruction prescribed by referred physician | 38.3 (54) | 32.6 (46) | 20.6 (29) | 6.4 (9) | 2.1 (3) | |
*The results of Chi-Square Test for Equal Proportions for all the factors were p < 0.01.