Literature DB >> 26078682

The effect of feeding with spoon and bottle on the time of switching to full breastfeeding and sucking success in preterm babies.

Aynur Aytekin1, Ebru Betül Albayrak2, Sibel Küçükoğlu1, İbrahim Caner3.   

Abstract

AIM: This research was conducted to determine the effect of the feeding methods of spoonfeed and feeding by bottle on the time of switching to full breastfeeding and sucking success.
MATERIAL AND METHODS: The study was conducted between September 2013 and January 2014 at the primary level of the neonatal intensive care clinics in two hospitals found in the eastern region of Turkey in a comperative and descriptive fashion. The population was composed of preterm babies who received treatment and care in these clinics during the period when the study was conducted and who met the criteria of the investigators. Without selecting the sample group the whole of the population was studied. The study was conducted with 37 preterm babies who were spoonfed and 35 preterm babies who were fed by bottle. The data were collected with "information form introducing preterm baby", "follow-up form for preterm baby" and "LATCH Breastfeeding Assessment Tool". The data were evaluated using percentage distribution, mean, chi-square test, t-test in independent groups, Cronbach alpha coefficient and McNemar analysis. Ethics committee approval was obtained from Atatürk University Faculty of Health Sciences (dated 08.05.2013) and official approvals were obtained from the related hospitals to conduct the study.
RESULTS: A significant difference was found between the mean times of switching to full breastfeeding from the first breast-feeding in preterm babies in the spoonfed group and bottle fed group in favour of the spoodfed group (p<0.05). No significant difference was found between the two groups in terms of starting breastfeeding, switching to full breastfeeding, the mean weights at discharge and the mean times of discharge (p>0.05). While no significant difference was found between the groups in terms of mean LATCH scores measured initially (p>0.05), the mean scores in the spoonfed group at the second and final measurement were found to be statistically significantly higher (p<0.05).
CONCLUSIONS: It was found that the preterm babies in whom spoonfeeding was used as a supportive method in addition to breast-feeding switched to full breastfeeding in a shorter time compared to the babies who were fed by bottle and their sucking success was at a better level.

Entities:  

Keywords:  Feeding by bottle; full breastfeeding; preterm baby; spoonfeed; sucking success

Year:  2014        PMID: 26078682      PMCID: PMC4462321          DOI: 10.5152/tpa.2014.1904

Source DB:  PubMed          Journal:  Turk Pediatri Ars


  17 in total

1.  Cup-feeding for preterm infants: mechanics and safety.

Authors:  Donna A Dowling; Paula P Meier; Juliann M DiFiore; MaryAnn Blatz; Richard J Martin
Journal:  J Hum Lact       Date:  2002-02       Impact factor: 2.219

2.  Cup feeding: an alternative to bottle feeding in a neonatal intensive care unit.

Authors:  A Gupta; K Khanna; S Chattree
Journal:  J Trop Pediatr       Date:  1999-04       Impact factor: 1.165

3.  Cup feeding of newborn infants.

Authors:  R C FREDEEN
Journal:  Pediatrics       Date:  1948-11       Impact factor: 7.124

4.  Spoon feeds--an alternative to bottle feeding.

Authors:  P M Nair; A Narang; R Mahajan; U Arora
Journal:  Indian Pediatr       Date:  1994-12       Impact factor: 1.411

5.  Cup feeding: an alternative method of infant feeding.

Authors:  S Lang; C J Lawrence; R L Orme
Journal:  Arch Dis Child       Date:  1994-10       Impact factor: 3.791

6.  The effect of breast- and bottle-feeding on oxygen saturation and body temperature in preterm infants.

Authors:  C H Chen; T M Wang; H M Chang; C S Chi
Journal:  J Hum Lact       Date:  2000-02       Impact factor: 2.219

7.  A controlled trial of alternative methods of oral feeding in neonates.

Authors:  N Malhotra; L Vishwambaran; K R Sundaram; I Narayanan
Journal:  Early Hum Dev       Date:  1999-02       Impact factor: 2.079

8.  Breastfeeding infants who were extremely low birth weight.

Authors:  J A Blaymore Bier; A E Ferguson; Y Morales; J A Liebling; W Oh; B R Vohr
Journal:  Pediatrics       Date:  1997-12       Impact factor: 7.124

9.  Coordination of breathing, sucking, and swallowing during bottle feedings in human infants.

Authors:  J S Koenig; A M Davies; B T Thach
Journal:  J Appl Physiol (1985)       Date:  1990-11

10.  Breastfeeding promotion: feeding the low birth weight infant.

Authors:  R N Musoke
Journal:  Int J Gynaecol Obstet       Date:  1990       Impact factor: 3.561

View more
  4 in total

Review 1.  Avoidance of bottles during the establishment of breastfeeds in preterm infants.

Authors:  Elizabeth Allen; Alice R Rumbold; Amy Keir; Carmel T Collins; Jennifer Gillis; Hiroki Suganuma
Journal:  Cochrane Database Syst Rev       Date:  2021-10-21

Review 2.  Avoidance of bottles during the establishment of breast feeds in preterm infants.

Authors:  Carmel T Collins; Jennifer Gillis; Andrew J McPhee; Hiroki Suganuma; Maria Makrides
Journal:  Cochrane Database Syst Rev       Date:  2016-10-19

3.  The Jaw Epidemic: Recognition, Origins, Cures, and Prevention.

Authors:  Sandra Kahn; Paul Ehrlich; Marcus Feldman; Robert Sapolsky; Simon Wong
Journal:  Bioscience       Date:  2020-07-22       Impact factor: 8.589

4.  An alternative supplemental feeding method for preterm infants: the supplemental feeding tube device

Authors:  Müjde Çalıkuşu İncekar; Seda Çağlar; Fatma Kaya Narter; Emriye Tercan Tarakcı; Emine Özpınar; Esra Demirci Ecevit
Journal:  Turk J Med Sci       Date:  2021-08-30       Impact factor: 0.973

  4 in total