Literature DB >> 26078144

Chemometrics-assisted cyclodextrin-enhanced excitation-emission fluorescence spectroscopy for the simultaneous green determination of bisphenol A and nonylphenol in plastics.

Rocío B Pellegrino Vidal1, Gabriela A Ibañez1, Graciela M Escandar2.   

Abstract

The aim of this work was to quantify two relevant priority chemicals, bisphenol A (BPA) and 4-nonylphenol (NP), coupling the sensitivity of fluorescence in organized media and the selectivity of multivariate calibration, measuring excitation-emission fluorescence matrices in an aqueous methyl-β-cyclodextrin solution. The studied priority pollutants are two of the most frequently found xenoestrogens in the environment, and are therefore of public health concern.The data were successfully processed by applying unfolded partial least-squares coupled to residual bilinearization (U-PLS/RBL), which provided the required selectivity for overcoming the severe spectral overlapping among the analyte spectra and also those for the interferents present in real samples. A rigorous International Union of Pure and Applied Chemistry (IUPAC)-consistent approach was applied for the calculation of the limits of detection. Values in the ranges of 1-2 and 4-14 ng mL(-1) were obtained in validation samples for BPA and NP, respectively. On the other hand, low relative prediction errors between 3% and 8% were achieved. The proposed method was successfully applied to the determination of BPA and NP in different plastics. In positive samples, after an easy treatment with a small volume of ethanol at 35°C, concentrations were found to range from 26 to 199 ng g(-1) for BPA, and from 95 to 30,000 ng g(-1) for NP.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  4-Nonylphenol; Bisphenol A; Methyl-β-cyclodextrin; Spectrofluorimetry; Unfolded partial least-squares coupled to residual bilinearization

Mesh:

Substances:

Year:  2015        PMID: 26078144     DOI: 10.1016/j.talanta.2015.05.030

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Electrochemical Sensor Based on Glassy-Carbon Electrode Modified with Dual-Ligand EC-MOFs Supported on rGO for BPA.

Authors:  Rui-Hong Ye; Jin-Yang Chen; Di-Hui Huang; Yan-Jun Wang; Sheng Chen
Journal:  Biosensors (Basel)       Date:  2022-05-27

2.  Voltammetric aptasensor for bisphenol A based on double signal amplification via gold-coated multiwalled carbon nanotubes and an ssDNA-dye complex.

Authors:  Haiyu Li; Shounian Ding; Wan Wang; Qing Lv; Zhijuan Wang; Hua Bai; Qing Zhang
Journal:  Mikrochim Acta       Date:  2019-11-30       Impact factor: 5.833

3.  Aptamer based electrochemiluminescent determination of bisphenol A by using carboxylated graphitic carbon nitride.

Authors:  Hai-Xia Cao; Li Wang; Chang-Gang Pan; Yu-Sheng He; Guo-Xi Liang
Journal:  Mikrochim Acta       Date:  2018-09-17       Impact factor: 5.833

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.